The Impacts of Face Mask Use on Standard Automated Perimetry Results in Glaucoma Patients

被引:9
|
作者
Bayram, Nurettin [1 ]
Gundogan, Medine [1 ]
Ozsaygili, Cemal [1 ]
Vural, Esra [1 ]
Cicek, Ayse [1 ]
机构
[1] Univ Hlth Sci, Kayseri City Training & Res Hosp, Dept Ophthalmol, TR-38080 Kayseri, Turkey
关键词
face masks; glaucoma; standard automated perimetry; perimetric reliability parameters; visual field artifacts;
D O I
10.1097/IJG.0000000000001786
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: The coronavirus disease 2019 (COVID-19) spread rapidly worldwide, causing a severe outbreak. Because the disease is easily transmitted, face masks are a vital tool to slow the spread. The aim of this study is to investigate the impacts of face mask use on standard automated perimetry (SAP) results in glaucoma patients. Materials and Methods: All follow-up glaucoma patients who underwent SAP between May and October 2020 were enrolled in this study. In patients with low test reliability and/or visual field changes, SAP was repeated after repositioning and taping patients' face masks. Results: A total of 127 patients (59 female and 68 male) with a mean age of 59.8 +/- 10.3 years were included in the study. While 101 patients (79.5%) wore surgical face masks, 26 patients (20.5%) wore cloth face masks. Low SAP reliability appeared in 23 patients (18.1%), and inferior visual field defects were present in 3 patients (2.4%). The main effects of poorly fitting face masks on SAP reliability were increased fixation losses and false-positive errors (for both, P=0.001). Low SAP reliability was significantly higher in patients wearing cloth face masks than in those wearing surgical face masks (47.8% vs. 9.9%; P=0.0001). The face mask-related fogging of eyeglasses before SAP is a strong predictor of fogging of the trial lenses-related low SAP reliability (odds ratio: 27, 95% confidence interval: 5.48-132.92, P=0.0001). In all repeated SAPs, the patients' reliability parameters improved, and inferior visual field artifacts disappeared. Conclusions: Unsuitable face masks can cause either visual field artifacts, which may be interpreted as glaucoma progression or low test reliability. Taping the face masks' upper edges is an effective technique to prevent visual field artifacts and obtain good test reliability.
引用
收藏
页码:287 / 292
页数:6
相关论文
共 50 条
  • [1] Response to Letter to the Editor: The Impacts of Face Mask Use on Standard Automated Perimetry Results in Glaucoma Patients
    Bayram, Nurettin
    Gundogan, Medine
    Ozsaygili, Cemal
    Vural, Esra
    Cicek, Ayse
    JOURNAL OF GLAUCOMA, 2021, 30 (11) : 1015 - 1016
  • [2] Prospective and randomized comparison of frequency doubling perimetry vs standard automated perimetry in patients with glaucoma
    Kampmeier, J
    Eisert, B
    Buchwald, HJ
    Lang, GK
    Lang, GE
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2001, 218 (03) : 157 - 167
  • [3] Comparison of frequency doubling perimetry to standard achromatic automated perimetry in glaucoma
    Serguhn, S
    Spiegel, D
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1999, 40 (04) : S842 - S842
  • [4] Comparison of Size Modulation Standard Automated Perimetry and Conventional Standard Automated Perimetry with a 10-2 Test Program in Glaucoma Patients
    Hirasawa, Kazunori
    Takahashi, Natsumi
    Satou, Tsukasa
    Kasahara, Masayuki
    Matsumura, Kazuhiro
    Shoji, Nobuyuki
    CURRENT EYE RESEARCH, 2017, 42 (08) : 1160 - 1168
  • [5] Effect of yellow-tinted intraocular lens on standard automated perimetry and short wavelength automated perimetry in patients with glaucoma
    Nilforushan, Naveed
    Parsamanesh, Mohammad
    Yu, Fei
    Nassiri, Nariman
    Miraftabi, Arezoo
    Coleman, Anne L.
    MIDDLE EAST AFRICAN JOURNAL OF OPHTHALMOLOGY, 2014, 21 (03) : 216 - 219
  • [6] A comparison of long term variability in standard automated perimetry and short-wavelength automated perimetry in stable glaucoma patients
    Blumenthal, EZ
    Sample, PA
    Zangwill, L
    Lee, AC
    Kono, Y
    Weinreb, RN
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1999, 40 (04) : S581 - S581
  • [7] Standard automated perimetry and algorithms for monitoring glaucoma progression
    Scuderi, G. L.
    Cesareo, M.
    Perdicchi, A.
    Recupero, S. M.
    GLAUCOMA: AN OPEN WINDOW TO NEURODEGENERATION AND NEUROPROTECTION, 2008, 173 : 77 - 99
  • [8] Repeatability and correlation of a virtual reality perimeter with standard automated perimetry in glaucoma patients
    Chaudhry, Anisa Fatima
    Berneshawi, Andrew Raphael
    Liu, Jocelyn
    Shue, Ann
    Chang, Dolly
    Kim, Julia
    Chang, Robert T.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2022, 63 (07)
  • [9] Longitudinal Changes in the Useful Field of View and Standard Automated Perimetry in Patients with Glaucoma
    Vieira Lopes, Nara Lidia
    Gracitelli, Carolina Pelegrini
    Diniz-Filho, Alberto
    Paranhos, Augusto, Jr.
    Medeiros, Felipe A.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [10] EFFECT OF PATIENT EXPERIENCE ON THE RESULTS OF AUTOMATED PERIMETRY IN GLAUCOMA SUSPECT PATIENTS
    WERNER, EB
    KRUPIN, T
    ADELSON, A
    FEITL, ME
    OPHTHALMOLOGY, 1990, 97 (01) : 44 - 48