Comparison of Size Modulation Standard Automated Perimetry and Conventional Standard Automated Perimetry with a 10-2 Test Program in Glaucoma Patients

被引:2
|
作者
Hirasawa, Kazunori [1 ]
Takahashi, Natsumi [2 ]
Satou, Tsukasa [3 ]
Kasahara, Masayuki [4 ]
Matsumura, Kazuhiro [4 ]
Shoji, Nobuyuki [4 ]
机构
[1] Kitasato Univ, Sch Allied Hlth Sci, Dept Orthopt & Visual Sci, Sagamihara, Kanagawa, Japan
[2] Kitasato Univ Hosp, Dept Ophthalmol, Sagamihara, Kanagawa, Japan
[3] Int Univ Hlth & Welf, Dept Orthopt & Visual Sci, Sch Hlth Sci, Kitakanemaru, Tochigi, Japan
[4] Kitasato Univ, Sch Med, Dept Ophthalmol, Sagamihara, Kanagawa, Japan
基金
日本学术振兴会;
关键词
Conventional standard automated perimetry; Octopus; 600; perimeter; perimetry; size modulation standard automated perimetry; 10-2 test point; VISUAL-FIELD; FULL THRESHOLD; SPATIAL SUMMATION; SITA STANDARD; TEST POINTS; VARIABILITY; ALGORITHMS; REPEATABILITY; STRATEGIES; TARGETS;
D O I
10.1080/02713683.2017.1293114
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: This prospective observational study compared the performance of size modulation standard automated perimetry with the Octopus 600 10-2 test program, with stimulus size modulation during testing, based on stimulus intensity and conventional standard automated perimetry, with that of the Humphrey 10-2 test program in glaucoma patients.Methods: Eighty-seven eyes of 87 glaucoma patients underwent size modulation standard automated perimetry with Dynamic strategy and conventional standard automated perimetry using the SITA standard strategy. The main outcome measures were global indices, point-wise threshold, visual defect size and depth, reliability indices, and test duration; these were compared between size modulation standard automated perimetry and conventional standard automated perimetry.Results: Global indices and point-wise threshold values between size modulation standard automated perimetry and conventional standard automated perimetry were moderately to strongly correlated (p < 0.01). However, the correlation coefficient of point-wise threshold value for the central zone was significantly lower than that for the peripheral zone (2 > 33.40, p < 0.01). Better mean defect and point-wise threshold values were obtained with size modulation standard automated perimetry than with conventional standard automated perimetry, but the visual-field defect size was smaller (p < 0.01) and depth shallower (p < 0.01) on size modulation-standard automated perimetry than on conventional standard automated perimetry. The reliability indices, particularly the false-negative response, of size modulation standard automated perimetry were worse than those of conventional standard automated perimetry (p < 0.01). The test duration was 6.5% shorter with size modulation standard automated perimetry than with conventional standard automated perimetry (p = 0.02).Conclusions: Global indices and the point-wise threshold value of the two testing modalities correlated well. However, the potential of a large stimulus presented at an area with a decreased sensitivity with size modulation standard automated perimetry could underestimate the actual threshold in the 10-2 test protocol, as compared with conventional standard automated perimetry.
引用
收藏
页码:1160 / 1168
页数:9
相关论文
共 50 条
  • [1] Comparison of size modulation and conventional standard automated perimetry with the 24-2 test protocol in glaucoma patients
    Hirasawa, Kazunori
    Shoji, Nobuyuki
    Kasahara, Masayuki
    Matsumura, Kazuhiro
    Shimizu, Kimiya
    SCIENTIFIC REPORTS, 2016, 6
  • [2] Comparison of size modulation and conventional standard automated perimetry with the 24-2 test protocol in glaucoma patients
    Kazunori Hirasawa
    Nobuyuki Shoji
    Masayuki Kasahara
    Kazuhiro Matsumura
    Kimiya Shimizu
    Scientific Reports, 6
  • [3] Comparison of frequency doubling perimetry to standard achromatic automated perimetry in glaucoma
    Serguhn, S
    Spiegel, D
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1999, 40 (04) : S842 - S842
  • [4] Frequency-doubling perimetry: Comparison with standard automated perimetry to detect glaucoma
    Leeprechanon, Narakorn
    Giangiacomo, Annette
    Fontana, Hector
    Hoffman, Douglas
    Caprioli, Joseph
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2007, 143 (02) : 263 - 271
  • [5] COMPARISON OF HIGH-PASS RESOLUTION PERIMETRY AND STANDARD AUTOMATED PERIMETRY IN GLAUCOMA
    MARTINEZ, GA
    SAMPLE, PA
    WEINREB, RN
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1995, 119 (02) : 195 - 201
  • [6] Prospective and randomized comparison of frequency doubling perimetry vs standard automated perimetry in patients with glaucoma
    Kampmeier, J
    Eisert, B
    Buchwald, HJ
    Lang, GK
    Lang, GE
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2001, 218 (03) : 157 - 167
  • [7] A comparison of long term variability in standard automated perimetry and short-wavelength automated perimetry in stable glaucoma patients
    Blumenthal, EZ
    Sample, PA
    Zangwill, L
    Lee, AC
    Kono, Y
    Weinreb, RN
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1999, 40 (04) : S581 - S581
  • [8] Comparison of Standard Automated Perimetry, Frequency-Doubling Technology Perimetry, and Short-Wavelength Automated Perimetry for Detection of Glaucoma
    Liu, Shu
    Lam, Shi
    Weinreb, Robert N.
    Ye, Cong
    Cheung, Carol Y.
    Lai, Gilda
    Lam, Dennis Shun-Chiu
    Leung, Christopher Kai-Shun
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2011, 52 (10) : 7325 - 7331
  • [9] Repeatability of Automated Perimetry: A Comparison between Standard Automated Perimetry with Stimulus Size III and V, Matrix, and Motion Perimetry
    Wall, Michael
    Woodward, Kimberly R.
    Doyle, Carrie K.
    Artes, Paul H.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2009, 50 (02) : 974 - 979
  • [10] Online Circular Contrast Perimetry: A Comparison to Standard Automated Perimetry
    Meyerov, Joshua
    Deng, Yuanchen
    Busija, Lazar
    Bigirimana, Deus
    Skalicky, Simon E.
    ASIA-PACIFIC JOURNAL OF OPHTHALMOLOGY, 2023, 12 (01): : 4 - 15