Comparison of Size Modulation Standard Automated Perimetry and Conventional Standard Automated Perimetry with a 10-2 Test Program in Glaucoma Patients

被引:2
|
作者
Hirasawa, Kazunori [1 ]
Takahashi, Natsumi [2 ]
Satou, Tsukasa [3 ]
Kasahara, Masayuki [4 ]
Matsumura, Kazuhiro [4 ]
Shoji, Nobuyuki [4 ]
机构
[1] Kitasato Univ, Sch Allied Hlth Sci, Dept Orthopt & Visual Sci, Sagamihara, Kanagawa, Japan
[2] Kitasato Univ Hosp, Dept Ophthalmol, Sagamihara, Kanagawa, Japan
[3] Int Univ Hlth & Welf, Dept Orthopt & Visual Sci, Sch Hlth Sci, Kitakanemaru, Tochigi, Japan
[4] Kitasato Univ, Sch Med, Dept Ophthalmol, Sagamihara, Kanagawa, Japan
基金
日本学术振兴会;
关键词
Conventional standard automated perimetry; Octopus; 600; perimeter; perimetry; size modulation standard automated perimetry; 10-2 test point; VISUAL-FIELD; FULL THRESHOLD; SPATIAL SUMMATION; SITA STANDARD; TEST POINTS; VARIABILITY; ALGORITHMS; REPEATABILITY; STRATEGIES; TARGETS;
D O I
10.1080/02713683.2017.1293114
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: This prospective observational study compared the performance of size modulation standard automated perimetry with the Octopus 600 10-2 test program, with stimulus size modulation during testing, based on stimulus intensity and conventional standard automated perimetry, with that of the Humphrey 10-2 test program in glaucoma patients.Methods: Eighty-seven eyes of 87 glaucoma patients underwent size modulation standard automated perimetry with Dynamic strategy and conventional standard automated perimetry using the SITA standard strategy. The main outcome measures were global indices, point-wise threshold, visual defect size and depth, reliability indices, and test duration; these were compared between size modulation standard automated perimetry and conventional standard automated perimetry.Results: Global indices and point-wise threshold values between size modulation standard automated perimetry and conventional standard automated perimetry were moderately to strongly correlated (p < 0.01). However, the correlation coefficient of point-wise threshold value for the central zone was significantly lower than that for the peripheral zone (2 > 33.40, p < 0.01). Better mean defect and point-wise threshold values were obtained with size modulation standard automated perimetry than with conventional standard automated perimetry, but the visual-field defect size was smaller (p < 0.01) and depth shallower (p < 0.01) on size modulation-standard automated perimetry than on conventional standard automated perimetry. The reliability indices, particularly the false-negative response, of size modulation standard automated perimetry were worse than those of conventional standard automated perimetry (p < 0.01). The test duration was 6.5% shorter with size modulation standard automated perimetry than with conventional standard automated perimetry (p = 0.02).Conclusions: Global indices and the point-wise threshold value of the two testing modalities correlated well. However, the potential of a large stimulus presented at an area with a decreased sensitivity with size modulation standard automated perimetry could underestimate the actual threshold in the 10-2 test protocol, as compared with conventional standard automated perimetry.
引用
收藏
页码:1160 / 1168
页数:9
相关论文
共 50 条
  • [41] Smartphone Perimetry: Comparison to Standard Automated Perimetry and Assessment of Size-Modulation Strategy with Frequency-Of-Seeing Curves in Healthy Subjects
    Wijayagunaratne, Anushi
    Linton, Edward
    Franch, Ivan Marin
    Alawa, Karam
    Wall, Michael
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2023, 64 (08)
  • [42] Automated combined kinetic and static perimetry - An alternative to standard perimetry in patients with neuro-ophthalmic disease and glaucoma
    Pineles, SL
    Volpe, NJ
    Miller-Ellis, E
    Galetta, SL
    Sankar, PS
    Shindler, KS
    Maguire, MG
    ARCHIVES OF OPHTHALMOLOGY, 2006, 124 (03) : 363 - 369
  • [43] Comparison of Saccadic Vector Optokinetic Perimetry and Standard Automated Perimetry in Glaucoma. Part I: Threshold Values and Repeatability
    Murray, Ian C.
    Perperidis, Antonios
    Cameron, Lorraine A.
    McTrusty, Alice D.
    Brash, Harry M.
    Tatham, Andrew J.
    Agarwal, Pankaj K.
    Fleck, Brian W.
    Minns, Robert A.
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2017, 6 (05):
  • [44] Comparison of 10-2 and 24-2 Perimetry to Diagnose Glaucoma Using OCT as an Independent Reference Standard
    Onyekaba, Ndidi-Amaka E.
    Estrela, Tais
    Naithani, Rizul
    McCarthy, Kayne M.
    Jammal, Alessandro A.
    Medeiros, Felipe A.
    OPHTHALMOLOGY GLAUCOMA, 2023, 6 (02): : 187 - 197
  • [45] Short-wavelength automated perimetry and motion automated perimetry in patients with glaucoma
    Sample, PA
    Bosworth, CF
    Weinreb, RN
    ARCHIVES OF OPHTHALMOLOGY, 1997, 115 (09) : 1129 - 1133
  • [46] Online circular contrast perimetry: Stability over time and comparison to standard automated perimetry
    Meyerov, Joshua
    Chen, Yang
    Green, Catherine
    Skalicky, Simon
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2023, 51 (09): : 990 - 990
  • [47] Comparison of frequency doubling perimetry and standard achromatic computerized perimetry in patients with glaucoma
    Serguhn, S
    Spiegel, D
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2001, 239 (05) : 351 - 355
  • [48] Comparison of frequency doubling perimetry and standard achromatic computerized perimetry in patients with glaucoma
    Stefan Serguhn
    Detlev Spiegel
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2001, 239 : 351 - 355
  • [49] Octopus Standard Automated Perimetry, Pulsar Perimetry, Moorfields Motion Displacement Test and Heidelberg Retinal Tomography in Glaucoma Detection - A Comparison of Diagnostic Accuracy
    Oleszczuk, J. D.
    Bergin, C.
    Schnyder, C.
    Crabb, D.
    Sharkawi, E.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [50] A COMPARISON OF GOLDMANN AND HUMPHREY AUTOMATED PERIMETRY IN PATIENTS WITH GLAUCOMA
    TROPE, GE
    BRITTON, R
    BRITISH JOURNAL OF OPHTHALMOLOGY, 1987, 71 (07) : 489 - 493