Comparison of Saccadic Vector Optokinetic Perimetry and Standard Automated Perimetry in Glaucoma. Part I: Threshold Values and Repeatability

被引:19
|
作者
Murray, Ian C. [1 ]
Perperidis, Antonios [1 ,2 ]
Cameron, Lorraine A. [1 ,3 ]
McTrusty, Alice D. [1 ,3 ]
Brash, Harry M. [1 ]
Tatham, Andrew J. [4 ]
Agarwal, Pankaj K. [4 ]
Fleck, Brian W. [1 ,4 ,5 ]
Minns, Robert A. [1 ,5 ]
机构
[1] Univ Edinburgh, Edinburgh, Midlothian, Scotland
[2] Heriot Watt Univ, Edinburgh, Midlothian, Scotland
[3] Glasgow Caledonian Univ, Glasgow, Lanark, Scotland
[4] Princess Alexandra Eye Pavil, Edinburgh, Midlothian, Scotland
[5] Royal Hosp Sick Children, Edinburgh, Midlothian, Scotland
来源
基金
英国惠康基金;
关键词
SVOP; eye movement perimetry; visual field; saccadic eye movements; TEST-RETEST VARIABILITY; VISUAL-FIELDS; SUPRATHRESHOLD; SITA;
D O I
10.1167/tvst.6.5.3
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: We evaluated threshold saccadic vector optokinetic perimetry (SVOP) and compared results to standard automated perimetry (SAP). Methods: A cross-sectional study was done including 162 subjects (103 with glaucoma and 59 healthy subjects) recruited at a university hospital. All subjects underwent SAP and threshold SVOP. SVOP uses an eye tracker to monitor eye movement responses to stimuli and determines if stimuli have been perceived based on the vector of the gaze response. The test pattern used was equivalent to SAP 24-2 and stimuli were presented at Goldmann III. Average and pointwise sensitivity values obtained from both tests were compared using Pearson's correlation coefficient. Two versions of SVOP were evaluated. Results: A total of 124 tests were performed with SAP and SVOP version 2. There was excellent agreement between mean threshold values obtained using SVOP and SAP (r = 0.95, P < 0.001). Excluding the blind spot, correlation between SVOP and SAP individual test point sensitivity ranged from 0.61 to 0.90, with 48 of 54 (89%) test points > 0.70. Overall SVOP showed good repeatability with a Pearson correlation of 0.88. The repeatability on a point-by-point basis ranged from 0.66 to 0.98, with 45 of 54 points (83%) > 0.80. Repeatability of SAP was 0.87, ranging from 0.69 to 0.96, with 47 of 54 (87%) points > 0.80. Conclusion: Eye-tracking perimetry is repeatable and compares well with the current gold standard of SAP. The technique has advantages over conventional perimetry and could be useful for evaluating glaucomatous visual field loss, particularly in patients who may struggle with conventional perimetry.
引用
收藏
页数:11
相关论文
共 45 条
  • [1] Comparison of Threshold Saccadic Vector Optokinetic Perimetry (SVOP) and Standard Automated Perimetry (SAP) in Glaucoma. Part II: Patterns of Visual Field Loss and Acceptability
    McTrusty, Alice D.
    Cameron, Lorraine A.
    Perperidis, Antonios
    Brash, Harry M.
    Tatham, Andrew J.
    Agarwal, Pankaj K.
    Murray, Ian C.
    Fleck, Brian W.
    Minns, Robert A.
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2017, 6 (05):
  • [2] Feasibility, Accuracy, and Repeatability of Suprathreshold Saccadic Vector Optokinetic Perimetry
    Murray, Ian C.
    Cameron, Lorraine A.
    McTrusty, Alice D.
    Perperidis, Antonios
    Brash, Harry M.
    Fleck, Brian W.
    Minns, Robert A.
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2016, 5 (04):
  • [3] Threshold visual field assessment using eye-tracking perimetry compared to standard automated perimetry in glaucoma.
    Tatham, Andrew J.
    Murray, Ian
    Perperidis, Antonios
    Cameron, Lorraine
    McTrusty, Alice
    Brash, Harry
    Fleck, Brian
    Minns, Robert
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [4] Feasibility of Saccadic Vector Optokinetic Perimetry A Method of Automated Static Perimetry for Children Using Eye Tracking
    Murray, Ian C.
    Fleck, Brian W.
    Brash, Harry M.
    MacRae, Mary E.
    Tan, Lai L.
    Minns, Robert A.
    OPHTHALMOLOGY, 2009, 116 (10) : 2017 - 2026
  • [5] Comparison of frequency doubling perimetry to standard achromatic automated perimetry in glaucoma
    Serguhn, S
    Spiegel, D
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1999, 40 (04) : S842 - S842
  • [6] Saccadic Vector Optokinetic Perimetry (SVOP): A Novel Technique for Automated Static Perimetry in Children Using Eye Tracking
    Murray, Ian
    Perperidis, Antonios
    Brash, Harry
    Cameron, Lorraine
    McTrusty, Alice
    Fleck, Brian
    Minns, Robert
    2013 35TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2013, : 3186 - 3189
  • [7] Repeatability of Automated Perimetry: A Comparison between Standard Automated Perimetry with Stimulus Size III and V, Matrix, and Motion Perimetry
    Wall, Michael
    Woodward, Kimberly R.
    Doyle, Carrie K.
    Artes, Paul H.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2009, 50 (02) : 974 - 979
  • [8] Frequency-doubling perimetry: Comparison with standard automated perimetry to detect glaucoma
    Leeprechanon, Narakorn
    Giangiacomo, Annette
    Fontana, Hector
    Hoffman, Douglas
    Caprioli, Joseph
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2007, 143 (02) : 263 - 271
  • [9] COMPARISON OF HIGH-PASS RESOLUTION PERIMETRY AND STANDARD AUTOMATED PERIMETRY IN GLAUCOMA
    MARTINEZ, GA
    SAMPLE, PA
    WEINREB, RN
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1995, 119 (02) : 195 - 201
  • [10] Comparison of Standard Automated Perimetry, Frequency-Doubling Technology Perimetry, and Short-Wavelength Automated Perimetry for Detection of Glaucoma
    Liu, Shu
    Lam, Shi
    Weinreb, Robert N.
    Ye, Cong
    Cheung, Carol Y.
    Lai, Gilda
    Lam, Dennis Shun-Chiu
    Leung, Christopher Kai-Shun
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2011, 52 (10) : 7325 - 7331