Comparison of Saccadic Vector Optokinetic Perimetry and Standard Automated Perimetry in Glaucoma. Part I: Threshold Values and Repeatability

被引:19
|
作者
Murray, Ian C. [1 ]
Perperidis, Antonios [1 ,2 ]
Cameron, Lorraine A. [1 ,3 ]
McTrusty, Alice D. [1 ,3 ]
Brash, Harry M. [1 ]
Tatham, Andrew J. [4 ]
Agarwal, Pankaj K. [4 ]
Fleck, Brian W. [1 ,4 ,5 ]
Minns, Robert A. [1 ,5 ]
机构
[1] Univ Edinburgh, Edinburgh, Midlothian, Scotland
[2] Heriot Watt Univ, Edinburgh, Midlothian, Scotland
[3] Glasgow Caledonian Univ, Glasgow, Lanark, Scotland
[4] Princess Alexandra Eye Pavil, Edinburgh, Midlothian, Scotland
[5] Royal Hosp Sick Children, Edinburgh, Midlothian, Scotland
来源
基金
英国惠康基金;
关键词
SVOP; eye movement perimetry; visual field; saccadic eye movements; TEST-RETEST VARIABILITY; VISUAL-FIELDS; SUPRATHRESHOLD; SITA;
D O I
10.1167/tvst.6.5.3
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: We evaluated threshold saccadic vector optokinetic perimetry (SVOP) and compared results to standard automated perimetry (SAP). Methods: A cross-sectional study was done including 162 subjects (103 with glaucoma and 59 healthy subjects) recruited at a university hospital. All subjects underwent SAP and threshold SVOP. SVOP uses an eye tracker to monitor eye movement responses to stimuli and determines if stimuli have been perceived based on the vector of the gaze response. The test pattern used was equivalent to SAP 24-2 and stimuli were presented at Goldmann III. Average and pointwise sensitivity values obtained from both tests were compared using Pearson's correlation coefficient. Two versions of SVOP were evaluated. Results: A total of 124 tests were performed with SAP and SVOP version 2. There was excellent agreement between mean threshold values obtained using SVOP and SAP (r = 0.95, P < 0.001). Excluding the blind spot, correlation between SVOP and SAP individual test point sensitivity ranged from 0.61 to 0.90, with 48 of 54 (89%) test points > 0.70. Overall SVOP showed good repeatability with a Pearson correlation of 0.88. The repeatability on a point-by-point basis ranged from 0.66 to 0.98, with 45 of 54 points (83%) > 0.80. Repeatability of SAP was 0.87, ranging from 0.69 to 0.96, with 47 of 54 (87%) points > 0.80. Conclusion: Eye-tracking perimetry is repeatable and compares well with the current gold standard of SAP. The technique has advantages over conventional perimetry and could be useful for evaluating glaucomatous visual field loss, particularly in patients who may struggle with conventional perimetry.
引用
收藏
页数:11
相关论文
共 45 条
  • [31] A Comparison of False-negative Responses for Full Threshold and SITA Standard Perimetry in Glaucoma Patients and Normal Observers
    Johnson, Chris A.
    Sherman, Kathryn
    Doyle, Carrie
    Wall, Michael
    JOURNAL OF GLAUCOMA, 2014, 23 (05) : 288 - 292
  • [32] Comparison of size modulation and conventional standard automated perimetry with the 24-2 test protocol in glaucoma patients
    Hirasawa, Kazunori
    Shoji, Nobuyuki
    Kasahara, Masayuki
    Matsumura, Kazuhiro
    Shimizu, Kimiya
    SCIENTIFIC REPORTS, 2016, 6
  • [33] Comparison of size modulation and conventional standard automated perimetry with the 24-2 test protocol in glaucoma patients
    Kazunori Hirasawa
    Nobuyuki Shoji
    Masayuki Kasahara
    Kazuhiro Matsumura
    Kimiya Shimizu
    Scientific Reports, 6
  • [34] Comparison of long-term variability for standard and short-wavelength automated perimetry in stable glaucoma patients
    Blumenthal, EZ
    Sample, PA
    Zangwill, L
    Lee, AC
    Kono, Y
    Weinreb, RN
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2000, 129 (03) : 309 - 313
  • [35] Comparison of diagnostic ability of standard automated perimetry, short wavelength automated perimetry, retinal nerve fiber layer thickness analysis and ganglion cell layer thickness analysis in early detection of glaucoma
    Kalyani, V. K. S.
    Bharucha, Khurshed M.
    Goyal, Nikhil
    Deshpande, Madan M.
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2021, 69 (05) : 1108 - 1112
  • [36] Probability of glaucoma determined from standard automated perimetry and from optic disk topography using relevance vector machine classifiers
    Goldbaum, M
    Sample, PA
    Zangwill, LM
    Bowd, C
    Boden, C
    Lee, TW
    Zhang, Z
    Hao, J
    Sejnowski, T
    Weinreb, RN
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U783 - U783
  • [37] Diagnostic sensitivity of fast blue-yellow and standard automated perimetry in early glaucoma - A comparison between different test programs
    Bengtsson, B
    Heijl, A
    OPHTHALMOLOGY, 2006, 113 (07) : 1092 - 1097
  • [38] A Comparison Among Microperimetry, Standard Automated Perimetry and Spectral Domain Optical Coherence Tomography in the Evaluation of the Macula in Glaucoma Eyes with Hemifield Defects
    Tian, Tian
    Cai, Yu
    Li, Mei
    Fang, Yuan
    Pan, Yingzi
    OPHTHALMOLOGY AND THERAPY, 2022, 11 (01) : 239 - 248
  • [39] A Comparison Among Microperimetry, Standard Automated Perimetry and Spectral Domain Optical Coherence Tomography in the Evaluation of the Macula in Glaucoma Eyes with Hemifield Defects
    Tian Tian
    Yu Cai
    Mei Li
    Yuan Fang
    Yingzi Pan
    Ophthalmology and Therapy, 2022, 11 : 239 - 248
  • [40] Comparison of isolated-check visual evoked potential and standard automated perimetry in early glaucoma and high-risk ocular hypertension
    Chen, Xiang-Wu
    Zhao, Ying-Xi
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2017, 10 (04) : 599 - 604