Comparison of size modulation and conventional standard automated perimetry with the 24-2 test protocol in glaucoma patients

被引:0
|
作者
Kazunori Hirasawa
Nobuyuki Shoji
Masayuki Kasahara
Kazuhiro Matsumura
Kimiya Shimizu
机构
[1] Orthoptics and Visual Science,Department of Rehabilitation
[2] School of Allied Health Sciences,Department of Ophthalmology
[3] Kitasato University,undefined
[4] School of Medicine,undefined
[5] Kitasato University,undefined
来源
关键词
D O I
暂无
中图分类号
学科分类号
摘要
This prospective randomized study compared test results of size modulation standard automated perimetry (SM-SAP) performed with the Octopus 600 and conventional SAP (C-SAP) performed with the Humphrey Field Analyzer (HFA) in glaucoma patients. Eighty-eight eyes of 88 glaucoma patients underwent SM-SAP and C-SAP tests with the Octopus 600 24-2 Dynamic and HFA 24-2 SITA-Standard, respectively. Fovea threshold, mean defect and square loss variance of SM-SAP were significantly correlated with the corresponding C-SAP indices (P < 0.001). The false-positive rate was slightly lower and false-negative rate slightly higher, with SM-SAP than C-SAP (P = 0.002). Point-wise threshold values obtained with SM-SAP were moderately to strongly correlated with those obtained with C-SAP (P < 0.001). The correlation coefficients of the central zone were significantly lower than those of the middle to peripheral zone (P = 0.031). The size and depth of the visual field (VF) defect were smaller (P = 0.039) and greater (P = 0.043), respectively, on SM-SAP than on C-SAP. Although small differences were observed in VF sensitivity in the central zone, the defect size and depth and the reliability indices between SM-SAP and C-SAP, global indices of the two testing modalities were well correlated.
引用
收藏
相关论文
共 50 条
  • [1] Comparison of size modulation and conventional standard automated perimetry with the 24-2 test protocol in glaucoma patients
    Hirasawa, Kazunori
    Shoji, Nobuyuki
    Kasahara, Masayuki
    Matsumura, Kazuhiro
    Shimizu, Kimiya
    SCIENTIFIC REPORTS, 2016, 6
  • [2] Comparison of Size Modulation Standard Automated Perimetry and Conventional Standard Automated Perimetry with a 10-2 Test Program in Glaucoma Patients
    Hirasawa, Kazunori
    Takahashi, Natsumi
    Satou, Tsukasa
    Kasahara, Masayuki
    Matsumura, Kazuhiro
    Shoji, Nobuyuki
    CURRENT EYE RESEARCH, 2017, 42 (08) : 1160 - 1168
  • [3] Comparison Between 24-2 SITA-Standard and 24-2 SITA-Fast Strategies in Standard Automated Perimetry
    Benenati, Brian
    Nassiri, Nariman
    Kim, Chaesik
    Swendris, Ronald
    Mas-Ramirez, Alma Michelle
    Tannir, Justin
    Goyal, Anju
    Juzych, Mark S.
    Hughes, Bret A.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [4] Comparison of Humphrey Matrix 24-2 standard perimetry and Humphrey Field Analyzer 24-2 SITA standard perimetry
    Bartlett, JD
    Shaikh, A
    Semes, L
    Xie, A
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [5] Comparison of 10-2 and 24-2 Perimetry to Diagnose Glaucoma Using OCT as an Independent Reference Standard
    Onyekaba, Ndidi-Amaka E.
    Estrela, Tais
    Naithani, Rizul
    McCarthy, Kayne M.
    Jammal, Alessandro A.
    Medeiros, Felipe A.
    OPHTHALMOLOGY GLAUCOMA, 2023, 6 (02): : 187 - 197
  • [6] Comparison of Frequency Doubling and Humphrey 24-2 Perimetry in normal tension glaucoma
    Bhagat, S
    Ramaesh, K
    Bolton, N
    Barron, AJ
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1999, 40 (04) : S842 - S842
  • [7] Comparison of Rates of Change in 10-2 and 24-2 Perimetry to Detect Glaucoma Progression
    Onyekaba, Ndidi-Amaka
    Jammal, Alessandro A.
    Estrela, Tais
    Naithani, Rizul
    Youssif, Asmaa
    Tseng, Henry
    Medeiros, Felipe
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2022, 63 (07)
  • [8] Comparison of frequency doubling perimetry to standard achromatic automated perimetry in glaucoma
    Serguhn, S
    Spiegel, D
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1999, 40 (04) : S842 - S842
  • [9] Prospective and randomized comparison of frequency doubling perimetry vs standard automated perimetry in patients with glaucoma
    Kampmeier, J
    Eisert, B
    Buchwald, HJ
    Lang, GK
    Lang, GE
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2001, 218 (03) : 157 - 167
  • [10] 24-2 SITA Standard versus 24-2 SITA Faster in Perimetry-Naive Normal Subjects
    Costa, Vital P.
    Zangalli, Camila S.
    Jammal, Alessandro A.
    Medeiros, Felipe A.
    Miyazaki, Joao V. M. K.
    Perez, Vanessa
    Boscaroli, Maria Leticia Nardi
    Schimiti, Rui B.
    OPHTHALMOLOGY GLAUCOMA, 2023, 6 (02): : 129 - 136