Evaluation of an edge method for computed radiography and an electronic portal imaging device in radiotherapy: Image quality measurements

被引:0
|
作者
Soon-Yong Son
Bo-Young Choe
Jeong-Woo Lee
Jung-Min Kim
Hoi-Woun Jeong
Ham-Gyum Kim
Wha-Sun Kim
Kwang-Yeul Lyu
Jung-Whan Min
Ki-Won Kim
机构
[1] Asan Medical Center,Department of Radiology
[2] The Catholic University of Korea,Department of Biomedical Engineering, Research Institute of Biomedical Engineering and College of Medicine
[3] Konkuk University Hospital,Department of Radiation Oncology
[4] Korea University,Department of College of Health Science, Radiologic Science
[5] The Baekseok Culture University College of Korea,Department of Radiological Technology
[6] The Ansan University College of Korea,Department of Radiological Science
[7] The Shingu University College of Korea,Department of Radiology Team
[8] Samsung Medical Center,undefined
来源
关键词
Modulation transfer function (MTF); Megavoltage X-ray imaging (MVI); Detective quantum efficiency (DQE);
D O I
暂无
中图分类号
学科分类号
摘要
Regular quality assurance (QA) of image quality is essential for reasonable patient dose and accurate treatment. Thus, QA should be performed as a routine for correction. The purpose of this study was to evaluate the modulation transfer function (MTF), the noise power spectrum (NPS) and the detective quantum efficiency (DQE) of the computed radiography (CR) system and the digital radiography (DR) system by using the edge method in megavoltage X-ray imaging (MVI). We used an edge block, which consisting of tungsten with dimensions of 19 (thickness) × 10 (length) × 1 (width) cm3 and measured the pre-sampling MTF by using a 6-megavolt (MV) energy. Computed radiography with an image plate (CR-IP) showed the values of 0.4 mm−1 and 1.19 mm−1 for MTF 0.5 and 0.1. In the DR group, Elekta iViewGT showed the highest value of 0.27 mm−1 for MTF 0.5, and Siemens BEAMVIEWPLUS showed the highest value of 0.98 mm−1 for MTF 0.1. In CR, the NPS of CR-IP showed a favorable noise distribution. Thus, in the DR group, the NPS of Elekta iViewGT showed the highest noise distribution. CR-IP showed values at peak DQE and 1 mm−1 DQE of 0.0013 and 0.00011, respectively. In the DR group, Elekta iViewGT showed the best efficiency at a peak DQE of 0.0009, and Siemens BEAMVIEWPLUS showed the best efficiency at a 1-mm−1 DQE of 0.000008. The edge method produced fast assessments of the MTF and the DQE. We could validate the evaluation of the edge method by comparing of the CR system to the DR system. This study demonstrated that the edge method can be used for not only traditional QA imaging but also quantitative MTF, NPS and DQE measurements in detector development.
引用
收藏
页码:1976 / 1984
页数:8
相关论文
共 50 条
  • [1] Evaluation of an Edge Method for Computed Radiography and an Electronic Portal Imaging Device in Radiotherapy: Image Quality Measurements
    Son, Soon-Yong
    Choe, Bo-Young
    Lee, Jeong-Woo
    Kim, Jung-Min
    Jeong, Hoi-Woun
    Kim, Ham-Gyum
    Kim, Wha-Sun
    Lyu, Kwang-Yeul
    Min, Jung-Whan
    Kim, Ki-Won
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2014, 65 (11) : 1976 - 1984
  • [2] Performance of electronic portal imaging devices (EPIDs) used in radiotherapy:: Image quality and dose measurements
    Cremers, F
    Frenzel, T
    Kausch, C
    Albers, D
    Schönborn, T
    Schmidt, R
    MEDICAL PHYSICS, 2004, 31 (05) : 985 - 996
  • [4] An Evaluation of Imaging Plate Characteristics that Determine Image Quality in Computed Radiography
    Silva, A. S. S.
    Oliveira, D. F.
    Machado, A. S.
    Nascimento, J. R.
    Lopes, R. T.
    MATERIALS EVALUATION, 2014, 72 (03) : 398 - 403
  • [5] Evaluation of quality assurance phantom for electronic portal imaging device (EPID)
    Das, I.
    Cheng, C.
    Chopra, K.
    Misic, V.
    Schule, E.
    MEDICAL PHYSICS, 2007, 34 (06) : 2371 - 2372
  • [6] An observer study: comparison of computed radiography to electronic and film portal imaging
    Roberts, N.
    Stanley, S.
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2006, 5 (04) : 197 - 202
  • [7] A Novel Method for Fast Image Simulation of Electronic Portal Imaging Device (EPID)
    Shi, M.
    Myronakis, M.
    Hu, Y.
    Berbeco, R.
    MEDICAL PHYSICS, 2018, 45 (06) : E478 - E478
  • [8] PORTAL DOSE MEASUREMENT IN RADIOTHERAPY USING AN ELECTRONIC PORTAL IMAGING DEVICE (EPID)
    HEIJMEN, BJM
    PASMA, KL
    KROONWIJK, M
    ALTHOF, VGM
    DEBOER, JCJ
    VISSER, AG
    HUIZENGA, H
    PHYSICS IN MEDICINE AND BIOLOGY, 1995, 40 (11): : 1943 - 1955
  • [9] Clinical practice and evaluation of electronic portal imaging device for VMAT quality assurance
    Huang, Yen-Cho
    Yeh, Chien-Yi
    Yeh, Jih-Hsiang
    Lo, Ching-Jung
    Tsai, Ping-Fang
    Hung, Chih-Hung
    Tsai, Chieh-Sheng
    Chen, Chen-Yuan
    MEDICAL DOSIMETRY, 2013, 38 (01) : 35 - 41
  • [10] Quality assurance of Linac-based stereotactic radiotherapy with electronic portal image device (WIP)
    Hsu, CW
    Liu, WS
    Chang, HC
    Chuang, KS
    Chen, TJ
    Tsai, CT
    MEDICAL PHYSICS, 2003, 30 (06) : 1520 - 1520