Clinical practice and evaluation of electronic portal imaging device for VMAT quality assurance

被引:10
|
作者
Huang, Yen-Cho [1 ]
Yeh, Chien-Yi [2 ]
Yeh, Jih-Hsiang [1 ]
Lo, Ching-Jung [2 ]
Tsai, Ping-Fang [2 ]
Hung, Chih-Hung [2 ]
Tsai, Chieh-Sheng [1 ]
Chen, Chen-Yuan [2 ]
机构
[1] Chang Gung Mem Hosp, Dept Radiat Oncol, Keelung Branch, Keelung 20445, Taiwan
[2] Chang Gung Mem Hosp, Dept Radiat Oncol, Linkou Branch, Tao Yuan, Taoyuan County, Taiwan
关键词
IMAT; EPID; RapidArc; Quality assurance; VMAT; DOSE-RESPONSE CHARACTERISTICS; FIXED FIELD IMRT; MODULATED ARC; CORRECTION ALGORITHM; GLAAS ALGORITHM; DOSIMETRY; RADIOTHERAPY; DELIVERY; RAPIDARC; THERAPY;
D O I
10.1016/j.meddos.2012.05.004
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Volumetric-modulated arc therapy (VMAT) is a novel extension of the intensity-modulated radiation therapy (IMRT) technique, which has brought challenges to dose verification. To perform VMAT pretreatment quality assurance, an electronic portal imaging device (EPID) can be applied. This study's aim was to evaluate EPID performance for VMAT dose verification. First, dosimetric characteristics of EPID were investigated. Then 10 selected VMAT dose plans were measured by EPID with the rotational method. The overall variation of EPID dosimetric characteristics was within 1.4% for VMAT. The film system serving as a conventional tool for verification showed good agreement both with EPID measurements ([94.1 +/- 1.5]% with 3 mm/3% criteria) and treatment planning system (TPS) calculations ([97.4 +/- 2.8]% with 3 mm/3% criteria). In addition, EPID measurements for VMAT presented good agreement with TPS calculations ([99.1 +/- 0.6]% with 3 mm/3% criteria). The EPID system performed the robustness of potential error findings in TPS calculations and the delivery system. This study demonstrated that an EPID system can be used as a reliable and efficient quality assurance tool for VMAT dose verification. (c) 2013 American Association of Medical Dosimetrists.
引用
收藏
页码:35 / 41
页数:7
相关论文
共 50 条
  • [1] Commissioning and periodic quality assurance of a clinical electronic portal imaging device
    Low, DA
    Klein, EE
    Maag, DK
    Umfleet, WE
    Purdy, JA
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 34 (01): : 117 - 123
  • [2] Evaluation of quality assurance phantom for electronic portal imaging device (EPID)
    Das, I.
    Cheng, C.
    Chopra, K.
    Misic, V.
    Schule, E.
    MEDICAL PHYSICS, 2007, 34 (06) : 2371 - 2372
  • [3] Comparison of pretreatment VMAT quality assurance with the integral quality monitor (IQM) and electronic portal imaging device (EPID)
    Ghafarian, Melissa
    Price, Michael
    Morales-Paliza, Manuel
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (03): : 166 - 175
  • [4] Evaluation of Electronic Portal Imaging Device in the Quality Assurance of Volumetric Modulated Arc Therapy
    Liu, Z.
    Chan, P.
    Li, S.
    Micaily, B.
    Miyamoto, C.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [5] Implementation of the Electronic Portal Imaging Device for Daily CyberKnife Quality Assurance
    Wang, L.
    Lo, A.
    Ho, A.
    MEDICAL PHYSICS, 2018, 45 (06) : E327 - E327
  • [6] LINAC Quality Assurance and Calibration Using Electronic Portal Imaging Device
    Ramirez, H.
    Yan, D.
    Zhang, T.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [7] Prospective clinical evaluation of an electronic portal imaging device
    Michalski, JM
    Graham, MV
    Bosch, WR
    Wong, J
    Gerber, RL
    Cheng, A
    Tinger, A
    Valicenti, RK
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 34 (04): : 943 - 951
  • [8] Quality assurance of electron beams using a Varian electronic portal imaging device
    Wang, Y.
    Heaton, R.
    Norrlinger, B.
    Islam, M.
    PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (16): : 5461 - 5475
  • [9] Evaluation of AutoCAL for electronic portal imaging device-based multi-leaf collimator quality assurance
    Shameem T.J.
    Radiological Physics and Technology, 2016, 9 (1) : 95 - 98
  • [10] Commissioning of An In-Vivo Quality Assurance Method Using the Electronic Portal Imaging Device
    Morin, O.
    Held, M.
    Pouliot, J.
    MEDICAL PHYSICS, 2014, 41 (06) : 326 - 327