Clinical practice and evaluation of electronic portal imaging device for VMAT quality assurance

被引:10
|
作者
Huang, Yen-Cho [1 ]
Yeh, Chien-Yi [2 ]
Yeh, Jih-Hsiang [1 ]
Lo, Ching-Jung [2 ]
Tsai, Ping-Fang [2 ]
Hung, Chih-Hung [2 ]
Tsai, Chieh-Sheng [1 ]
Chen, Chen-Yuan [2 ]
机构
[1] Chang Gung Mem Hosp, Dept Radiat Oncol, Keelung Branch, Keelung 20445, Taiwan
[2] Chang Gung Mem Hosp, Dept Radiat Oncol, Linkou Branch, Tao Yuan, Taoyuan County, Taiwan
关键词
IMAT; EPID; RapidArc; Quality assurance; VMAT; DOSE-RESPONSE CHARACTERISTICS; FIXED FIELD IMRT; MODULATED ARC; CORRECTION ALGORITHM; GLAAS ALGORITHM; DOSIMETRY; RADIOTHERAPY; DELIVERY; RAPIDARC; THERAPY;
D O I
10.1016/j.meddos.2012.05.004
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Volumetric-modulated arc therapy (VMAT) is a novel extension of the intensity-modulated radiation therapy (IMRT) technique, which has brought challenges to dose verification. To perform VMAT pretreatment quality assurance, an electronic portal imaging device (EPID) can be applied. This study's aim was to evaluate EPID performance for VMAT dose verification. First, dosimetric characteristics of EPID were investigated. Then 10 selected VMAT dose plans were measured by EPID with the rotational method. The overall variation of EPID dosimetric characteristics was within 1.4% for VMAT. The film system serving as a conventional tool for verification showed good agreement both with EPID measurements ([94.1 +/- 1.5]% with 3 mm/3% criteria) and treatment planning system (TPS) calculations ([97.4 +/- 2.8]% with 3 mm/3% criteria). In addition, EPID measurements for VMAT presented good agreement with TPS calculations ([99.1 +/- 0.6]% with 3 mm/3% criteria). The EPID system performed the robustness of potential error findings in TPS calculations and the delivery system. This study demonstrated that an EPID system can be used as a reliable and efficient quality assurance tool for VMAT dose verification. (c) 2013 American Association of Medical Dosimetrists.
引用
收藏
页码:35 / 41
页数:7
相关论文
共 50 条
  • [21] RapidArc treatment planning quality assurance using electronic portal imaging device for cervical cancer
    Zulkafal, Hafiz Muhibb Ullah
    Khalid, Allah Ditta
    Minhas, Sajid Anees
    Zafar, Umair
    Hameed, Rizwan
    Afzal Khan, Muhammad
    Iqbal, Khalid
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2020, 19 (02) : 139 - 144
  • [22] IMRT/VMAT Quality Assurance Using Portal Dosimetry
    Pan, X.
    Ochran, T.
    Bradley, W.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [23] Filmless Quality Assurance for Linear Accelerator with Electronic Portal Image Device
    Chen, H.
    Jacob, D.
    Simpson, L.
    Chen, W.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [24] Quality assurance of RapidArc in clinical practice using portal dosimetry
    Fogliata, A.
    Clivio, A.
    Fenoglietto, P.
    Hrbacek, J.
    Kloeck, S.
    Lattuada, P.
    Mancosu, P.
    Nicolini, G.
    Parietti, E.
    Urso, G.
    Vanetti, E.
    Cozzi, L.
    BRITISH JOURNAL OF RADIOLOGY, 2011, 84 (1002): : 534 - 545
  • [25] A method for in vivo treatment verification of IMRT and VMAT based on electronic portal imaging device
    Jun Zhang
    Xiuqing Li
    Miaomiao Lu
    Qilin Zhang
    Xile Zhang
    Ruijie Yang
    Maria F. Chan
    Junhai Wen
    Radiation Oncology, 16
  • [26] Evaluation of an electronic portal imaging device for transit dosimetry
    He, XD
    Van Esch, A
    Reymen, R
    Huyskens, D
    ACTA ONCOLOGICA, 1999, 38 (05) : 591 - 596
  • [27] Evaluation of an electronic portal imaging device for transit dosimetry
    He, Xiaodong
    Esch, Ann Van
    Reymen, Rita
    Huyskens, Dominique
    Acta Oncologica, 38 (05): : 591 - 596
  • [28] A method for in vivo treatment verification of IMRT and VMAT based on electronic portal imaging device
    Zhang, Jun
    Li, Xiuqing
    Lu, Miaomiao
    Zhang, Qilin
    Zhang, Xile
    Yang, Ruijie
    Chan, Maria F.
    Wen, Junhai
    RADIATION ONCOLOGY, 2021, 16 (01)
  • [29] Using an Electronic Portal Imaging Device for Patient-Specific Volumetric Modulated Arc Therapy Quality Assurance
    Bakhtiari, M.
    Kumaraswamy, L.
    de Boer, S.
    Malhotra, H.
    Podgorsak, M.
    MEDICAL PHYSICS, 2010, 37 (06) : 3087 - +
  • [30] Use of Electronic Portal Imaging Device (EPID) for Quality Assurance (QA) of Electron Beams On Varian Truebeam System
    Cai, B.
    Yaddanapudi, S.
    Sun, B.
    Li, H.
    Noel, C.
    Mutic, S.
    Goddu, S.
    MEDICAL PHYSICS, 2015, 42 (06) : 3515 - 3515