Clinical practice and evaluation of electronic portal imaging device for VMAT quality assurance

被引:10
|
作者
Huang, Yen-Cho [1 ]
Yeh, Chien-Yi [2 ]
Yeh, Jih-Hsiang [1 ]
Lo, Ching-Jung [2 ]
Tsai, Ping-Fang [2 ]
Hung, Chih-Hung [2 ]
Tsai, Chieh-Sheng [1 ]
Chen, Chen-Yuan [2 ]
机构
[1] Chang Gung Mem Hosp, Dept Radiat Oncol, Keelung Branch, Keelung 20445, Taiwan
[2] Chang Gung Mem Hosp, Dept Radiat Oncol, Linkou Branch, Tao Yuan, Taoyuan County, Taiwan
关键词
IMAT; EPID; RapidArc; Quality assurance; VMAT; DOSE-RESPONSE CHARACTERISTICS; FIXED FIELD IMRT; MODULATED ARC; CORRECTION ALGORITHM; GLAAS ALGORITHM; DOSIMETRY; RADIOTHERAPY; DELIVERY; RAPIDARC; THERAPY;
D O I
10.1016/j.meddos.2012.05.004
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Volumetric-modulated arc therapy (VMAT) is a novel extension of the intensity-modulated radiation therapy (IMRT) technique, which has brought challenges to dose verification. To perform VMAT pretreatment quality assurance, an electronic portal imaging device (EPID) can be applied. This study's aim was to evaluate EPID performance for VMAT dose verification. First, dosimetric characteristics of EPID were investigated. Then 10 selected VMAT dose plans were measured by EPID with the rotational method. The overall variation of EPID dosimetric characteristics was within 1.4% for VMAT. The film system serving as a conventional tool for verification showed good agreement both with EPID measurements ([94.1 +/- 1.5]% with 3 mm/3% criteria) and treatment planning system (TPS) calculations ([97.4 +/- 2.8]% with 3 mm/3% criteria). In addition, EPID measurements for VMAT presented good agreement with TPS calculations ([99.1 +/- 0.6]% with 3 mm/3% criteria). The EPID system performed the robustness of potential error findings in TPS calculations and the delivery system. This study demonstrated that an EPID system can be used as a reliable and efficient quality assurance tool for VMAT dose verification. (c) 2013 American Association of Medical Dosimetrists.
引用
收藏
页码:35 / 41
页数:7
相关论文
共 50 条
  • [31] Motion of Electronic Portal Imaging Devices and Clinical Implications for Multi-Leaf Collimator Quality Assurance
    Nasehi Tehrani, J.
    Kalavagunta, C.
    Lasio, G.
    Chen, S.
    Yi, B.
    MEDICAL PHYSICS, 2020, 47 (06) : E639 - E639
  • [32] OPTIMIZATION AND EVALUATION OF THE PORTAL DOSIMETRY PROFILE CORRECTION FOR AN ELECTRONIC PORTAL IMAGING DEVICE
    Samsoe, E.
    Sjostrom, D.
    Karlsson, A.
    Behrens, C.
    Van Esch, A.
    RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S215 - S215
  • [33] Quality assurance of geometric accuracy based on an electronic portal imaging device and log data analysis for Dynamic WaveArc irradiation
    Hirashima, Hideaki
    Miyabe, Yuki
    Nakamura, Mitsuhiro
    Mukumoto, Nobutaka
    Mizowaki, Takashi
    Hiraoka, Masahiro
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2018, 19 (03): : 234 - 242
  • [34] Patient Specific Quality Assurance of Prostate VMAT Plans with Portal Dosimetry
    Darko, J.
    Kiciak, A.
    Badu, S.
    Grigorov, G.
    Fleck, A.
    Osei, E.
    MEDICAL PHYSICS, 2016, 43 (06) : 3525 - 3525
  • [35] Quality control of VMAT synchronization using portal imaging
    Bedford, James L.
    Chajecka-Szczygielska, Honorata
    Thomas, Michael D. R.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2015, 16 (01): : 284 - 297
  • [36] Development of calibration Procedure of an Electronic Portal Imaging Device a-Si1000 Used for IMRT and VMAT
    Maachou, A.
    Toutaoui, A. E. K.
    Toutaoui-Khelassi, N.
    Louelh, R.
    Brahimi-Sakhri, Z.
    Chami, A. C.
    1ST INTERNATIONAL CONFERENCE ON RADIATIONS AND APPLICATIONS (ICRA-2017), 2018, 1994
  • [37] Twin machines validation for VMAT treatments using electronic portal-imaging device: a multicenter study
    Fenoglietto, P.
    Khodri, M.
    Nguyen, D.
    Josserand-Pietri, F.
    Ailleres, N.
    RADIATION ONCOLOGY, 2016, 11
  • [38] Twin machines validation for VMAT treatments using electronic portal-imaging device: a multicenter study
    P. Fenoglietto
    M. Khodri
    D. Nguyen
    F. Josserand-Pietri
    N. Aillères
    Radiation Oncology, 11
  • [39] Radiation Treatment Machine Mechanical Quality Assurance Check with Megavoltage Portal Imaging Device
    Yu, Y.
    Zhang, T.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [40] A study on dosimetric properties of electronic portal imaging device and its use as a quality assurance tool in Volumetric Modulated Arc Therapy
    Sukumar, Prabakar
    Padmanaban, Sriram
    Jeevanandam, Prakash
    Kumar, S. A. Syam
    Nagarajan, Vivekanandan
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2011, 16 (06) : 248 - 255