Clinical practice and evaluation of electronic portal imaging device for VMAT quality assurance

被引:10
|
作者
Huang, Yen-Cho [1 ]
Yeh, Chien-Yi [2 ]
Yeh, Jih-Hsiang [1 ]
Lo, Ching-Jung [2 ]
Tsai, Ping-Fang [2 ]
Hung, Chih-Hung [2 ]
Tsai, Chieh-Sheng [1 ]
Chen, Chen-Yuan [2 ]
机构
[1] Chang Gung Mem Hosp, Dept Radiat Oncol, Keelung Branch, Keelung 20445, Taiwan
[2] Chang Gung Mem Hosp, Dept Radiat Oncol, Linkou Branch, Tao Yuan, Taoyuan County, Taiwan
关键词
IMAT; EPID; RapidArc; Quality assurance; VMAT; DOSE-RESPONSE CHARACTERISTICS; FIXED FIELD IMRT; MODULATED ARC; CORRECTION ALGORITHM; GLAAS ALGORITHM; DOSIMETRY; RADIOTHERAPY; DELIVERY; RAPIDARC; THERAPY;
D O I
10.1016/j.meddos.2012.05.004
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Volumetric-modulated arc therapy (VMAT) is a novel extension of the intensity-modulated radiation therapy (IMRT) technique, which has brought challenges to dose verification. To perform VMAT pretreatment quality assurance, an electronic portal imaging device (EPID) can be applied. This study's aim was to evaluate EPID performance for VMAT dose verification. First, dosimetric characteristics of EPID were investigated. Then 10 selected VMAT dose plans were measured by EPID with the rotational method. The overall variation of EPID dosimetric characteristics was within 1.4% for VMAT. The film system serving as a conventional tool for verification showed good agreement both with EPID measurements ([94.1 +/- 1.5]% with 3 mm/3% criteria) and treatment planning system (TPS) calculations ([97.4 +/- 2.8]% with 3 mm/3% criteria). In addition, EPID measurements for VMAT presented good agreement with TPS calculations ([99.1 +/- 0.6]% with 3 mm/3% criteria). The EPID system performed the robustness of potential error findings in TPS calculations and the delivery system. This study demonstrated that an EPID system can be used as a reliable and efficient quality assurance tool for VMAT dose verification. (c) 2013 American Association of Medical Dosimetrists.
引用
收藏
页码:35 / 41
页数:7
相关论文
共 50 条
  • [41] A Simple Approach to Performing Light Versus Radiation Field Coincidence Quality Assurance Using An Electronic Portal Imaging Device (EPID)
    Herchko, S.
    Ding, G.
    MEDICAL PHYSICS, 2016, 43 (06) : 3575 - 3575
  • [42] Evaluation of an edge method for computed radiography and an electronic portal imaging device in radiotherapy: Image quality measurements
    Soon-Yong Son
    Bo-Young Choe
    Jeong-Woo Lee
    Jung-Min Kim
    Hoi-Woun Jeong
    Ham-Gyum Kim
    Wha-Sun Kim
    Kwang-Yeul Lyu
    Jung-Whan Min
    Ki-Won Kim
    Journal of the Korean Physical Society, 2014, 65 : 1976 - 1984
  • [43] Evaluation of an Edge Method for Computed Radiography and an Electronic Portal Imaging Device in Radiotherapy: Image Quality Measurements
    Son, Soon-Yong
    Choe, Bo-Young
    Lee, Jeong-Woo
    Kim, Jung-Min
    Jeong, Hoi-Woun
    Kim, Ham-Gyum
    Kim, Wha-Sun
    Lyu, Kwang-Yeul
    Min, Jung-Whan
    Kim, Ki-Won
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2014, 65 (11) : 1976 - 1984
  • [44] Megavoltage CT from Electronic Portal Imaging of VMAT Deliveries
    Wood, J. S.
    Marchant, T. E.
    Budgell, G. J.
    CLINICAL ONCOLOGY, 2011, 23 (03) : S18 - S18
  • [45] Quality assurance of Linac-based stereotactic radiotherapy with electronic portal image device (WIP)
    Hsu, CW
    Liu, WS
    Chang, HC
    Chuang, KS
    Chen, TJ
    Tsai, CT
    MEDICAL PHYSICS, 2003, 30 (06) : 1520 - 1520
  • [46] Application of a Quality Assurance Solution Based on an Electronic Field Imaging Device in Linac
    Tianlong Ji
    Lu Sun
    Hao Shen
    Guang Li
    ChineseJournalofBiomedicalEngineering, 2020, 29 (02) : 10 - 16
  • [47] Gantry-Resolved Linac QA for VMAT: A Comprehensive and Efficient System Using An Electronic Portal Imaging Device
    Zwan, B. J.
    Barnes, M.
    Hindmarsh, J.
    Seymour, E.
    O'Connor, D. J.
    Keall, P. J.
    Greer, P. B.
    MEDICAL PHYSICS, 2016, 43 (06) : 3712 - 3712
  • [48] Determination of the electronic portal imaging device pixel-sensitivity-map for quality assurance applications. Part 1: Comparison of methods
    Barnes, Michael Paul
    Sun, Baozhou
    Oborn, Brad Michael
    Lamichhane, Bishnu
    Szwec, Stuart
    Schmidt, Matthew
    Cai, Bin
    Menk, Frederick
    Greer, Peter
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2022, 23 (06):
  • [49] Quality assurance of MLC leaf position accuracy and relative dose effect at the MLC abutment region using an electronic portal imaging device
    Sumida, Iori
    Yamaguchi, Hajime
    Kizaki, Hisao
    Koizumi, Masahiko
    Ogata, Toshiyuki
    Takahashi, Yutaka
    Yoshioka, Yasuo
    JOURNAL OF RADIATION RESEARCH, 2012, 53 (05) : 798 - 806
  • [50] AUTOMATED QUALITY CONTROL OF THE MLC PERFORMANCE USING AN ELECTRONIC PORTAL IMAGING DEVICE
    De Brabandere, M.
    Hrbacek, J.
    Swinnen, A.
    Van den Heuvel, F.
    RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S381 - S381