Evaluation of an edge method for computed radiography and an electronic portal imaging device in radiotherapy: Image quality measurements

被引:0
|
作者
Soon-Yong Son
Bo-Young Choe
Jeong-Woo Lee
Jung-Min Kim
Hoi-Woun Jeong
Ham-Gyum Kim
Wha-Sun Kim
Kwang-Yeul Lyu
Jung-Whan Min
Ki-Won Kim
机构
[1] Asan Medical Center,Department of Radiology
[2] The Catholic University of Korea,Department of Biomedical Engineering, Research Institute of Biomedical Engineering and College of Medicine
[3] Konkuk University Hospital,Department of Radiation Oncology
[4] Korea University,Department of College of Health Science, Radiologic Science
[5] The Baekseok Culture University College of Korea,Department of Radiological Technology
[6] The Ansan University College of Korea,Department of Radiological Science
[7] The Shingu University College of Korea,Department of Radiology Team
[8] Samsung Medical Center,undefined
来源
关键词
Modulation transfer function (MTF); Megavoltage X-ray imaging (MVI); Detective quantum efficiency (DQE);
D O I
暂无
中图分类号
学科分类号
摘要
Regular quality assurance (QA) of image quality is essential for reasonable patient dose and accurate treatment. Thus, QA should be performed as a routine for correction. The purpose of this study was to evaluate the modulation transfer function (MTF), the noise power spectrum (NPS) and the detective quantum efficiency (DQE) of the computed radiography (CR) system and the digital radiography (DR) system by using the edge method in megavoltage X-ray imaging (MVI). We used an edge block, which consisting of tungsten with dimensions of 19 (thickness) × 10 (length) × 1 (width) cm3 and measured the pre-sampling MTF by using a 6-megavolt (MV) energy. Computed radiography with an image plate (CR-IP) showed the values of 0.4 mm−1 and 1.19 mm−1 for MTF 0.5 and 0.1. In the DR group, Elekta iViewGT showed the highest value of 0.27 mm−1 for MTF 0.5, and Siemens BEAMVIEWPLUS showed the highest value of 0.98 mm−1 for MTF 0.1. In CR, the NPS of CR-IP showed a favorable noise distribution. Thus, in the DR group, the NPS of Elekta iViewGT showed the highest noise distribution. CR-IP showed values at peak DQE and 1 mm−1 DQE of 0.0013 and 0.00011, respectively. In the DR group, Elekta iViewGT showed the best efficiency at a peak DQE of 0.0009, and Siemens BEAMVIEWPLUS showed the best efficiency at a 1-mm−1 DQE of 0.000008. The edge method produced fast assessments of the MTF and the DQE. We could validate the evaluation of the edge method by comparing of the CR system to the DR system. This study demonstrated that the edge method can be used for not only traditional QA imaging but also quantitative MTF, NPS and DQE measurements in detector development.
引用
收藏
页码:1976 / 1984
页数:8
相关论文
共 50 条
  • [41] Image Quality Evaluation of Electronic Portal Imaging Using 2.5 MV X-Ray
    Nagamine, S.
    Takakura, K.
    Fukunaga, J.
    Hirose, T.
    Hirano, N.
    Matsumoto, R.
    Hidaka, K.
    Hirayama, R.
    Nakanishi, D.
    MEDICAL PHYSICS, 2018, 45 (06) : E503 - E503
  • [42] Commissioning and periodic quality assurance of a clinical electronic portal imaging device
    Low, DA
    Klein, EE
    Maag, DK
    Umfleet, WE
    Purdy, JA
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 34 (01): : 117 - 123
  • [43] LINAC Quality Assurance and Calibration Using Electronic Portal Imaging Device
    Ramirez, H.
    Yan, D.
    Zhang, T.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [44] A method for controlling image acquisition in electronic portal imaging devices
    Glendinning, AG
    Hunt, SG
    Bonnett, DE
    PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (02): : N39 - N44
  • [45] Implementation of the Electronic Portal Imaging Device for Daily CyberKnife Quality Assurance
    Wang, L.
    Lo, A.
    Ho, A.
    MEDICAL PHYSICS, 2018, 45 (06) : E327 - E327
  • [46] THE CONTRAST-DETAIL-DOSE EVALUATION OF IMAGE QUALITY, WITH APPLICATION TO COMPUTED RADIOGRAPHY, COMPUTED-TOMOGRAPHY, AND CONVENTIONAL RADIOGRAPHY
    COHEN, G
    AMTEY, SR
    WAGNER, LK
    KATRAGADDA, C
    FOGEL, S
    HANDEL, SF
    LESTER, RG
    DIBIANCA, FA
    PHYSICS IN MEDICINE AND BIOLOGY, 1980, 25 (04): : 775 - 775
  • [47] Correlation of the clinical and physical image quality in chest radiography for average adults with a computed radiography imaging system
    Moore, C. S.
    Wood, T. J.
    Beavis, A. W.
    Saunderson, J. R.
    BRITISH JOURNAL OF RADIOLOGY, 2013, 86 (1027):
  • [48] A simple quality assurance test tool for the visual verification of light and radiation field congruent using electronic portal images device and computed radiography
    Njeh, Christopher F.
    Caroprese, Blas
    Desai, Pushkar
    RADIATION ONCOLOGY, 2012, 7
  • [49] In vivo dosimetry with an electronic portal imaging device for prostate cancer radiotherapy with an endorectal balloon
    Sterckx, Bo
    Steinseifer, Isabell
    Wendling, Markus
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2019, 12 : 7 - 9
  • [50] A simple quality assurance test tool for the visual verification of light and radiation field congruent using electronic portal images device and computed radiography
    Christopher F Njeh
    Blas Caroprese
    Pushkar Desai
    Radiation Oncology, 7