Evaluation of an edge method for computed radiography and an electronic portal imaging device in radiotherapy: Image quality measurements

被引:0
|
作者
Soon-Yong Son
Bo-Young Choe
Jeong-Woo Lee
Jung-Min Kim
Hoi-Woun Jeong
Ham-Gyum Kim
Wha-Sun Kim
Kwang-Yeul Lyu
Jung-Whan Min
Ki-Won Kim
机构
[1] Asan Medical Center,Department of Radiology
[2] The Catholic University of Korea,Department of Biomedical Engineering, Research Institute of Biomedical Engineering and College of Medicine
[3] Konkuk University Hospital,Department of Radiation Oncology
[4] Korea University,Department of College of Health Science, Radiologic Science
[5] The Baekseok Culture University College of Korea,Department of Radiological Technology
[6] The Ansan University College of Korea,Department of Radiological Science
[7] The Shingu University College of Korea,Department of Radiology Team
[8] Samsung Medical Center,undefined
来源
关键词
Modulation transfer function (MTF); Megavoltage X-ray imaging (MVI); Detective quantum efficiency (DQE);
D O I
暂无
中图分类号
学科分类号
摘要
Regular quality assurance (QA) of image quality is essential for reasonable patient dose and accurate treatment. Thus, QA should be performed as a routine for correction. The purpose of this study was to evaluate the modulation transfer function (MTF), the noise power spectrum (NPS) and the detective quantum efficiency (DQE) of the computed radiography (CR) system and the digital radiography (DR) system by using the edge method in megavoltage X-ray imaging (MVI). We used an edge block, which consisting of tungsten with dimensions of 19 (thickness) × 10 (length) × 1 (width) cm3 and measured the pre-sampling MTF by using a 6-megavolt (MV) energy. Computed radiography with an image plate (CR-IP) showed the values of 0.4 mm−1 and 1.19 mm−1 for MTF 0.5 and 0.1. In the DR group, Elekta iViewGT showed the highest value of 0.27 mm−1 for MTF 0.5, and Siemens BEAMVIEWPLUS showed the highest value of 0.98 mm−1 for MTF 0.1. In CR, the NPS of CR-IP showed a favorable noise distribution. Thus, in the DR group, the NPS of Elekta iViewGT showed the highest noise distribution. CR-IP showed values at peak DQE and 1 mm−1 DQE of 0.0013 and 0.00011, respectively. In the DR group, Elekta iViewGT showed the best efficiency at a peak DQE of 0.0009, and Siemens BEAMVIEWPLUS showed the best efficiency at a 1-mm−1 DQE of 0.000008. The edge method produced fast assessments of the MTF and the DQE. We could validate the evaluation of the edge method by comparing of the CR system to the DR system. This study demonstrated that the edge method can be used for not only traditional QA imaging but also quantitative MTF, NPS and DQE measurements in detector development.
引用
收藏
页码:1976 / 1984
页数:8
相关论文
共 50 条
  • [31] OPTIMIZATION AND EVALUATION OF THE PORTAL DOSIMETRY PROFILE CORRECTION FOR AN ELECTRONIC PORTAL IMAGING DEVICE
    Samsoe, E.
    Sjostrom, D.
    Karlsson, A.
    Behrens, C.
    Van Esch, A.
    RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S215 - S215
  • [32] Consistency of image quality measurements of computed radiography systems with implications for a quality control program
    Fetterly, KA
    Peterson, TM
    Daly, TR
    Schueler, BA
    RADIOLOGY, 2001, 221 : 158 - 158
  • [33] Investigating the Electronic Portal Imaging Device for Small Radiation Field Measurements
    Das, K. J. Maria
    Agarwal, A.
    Rastogi, N. Nikhil
    Yoganathan, S. A.
    Udayakumar, D.
    Kumar, S.
    MEDICAL PHYSICS, 2017, 44 (06) : 2887 - 2887
  • [34] Filter-modulated fluence measurements with an electronic portal imaging device
    Coughlin, M
    Leszczynski, K
    MEDICAL PHYSICS, 2002, 29 (06) : 1270 - 1271
  • [35] Computed radiography for neonatal chest imaging: The effect of image processing on the perception of image quality
    Don, S
    Whiting, BR
    Ellinwood, JS
    Foos, DH
    Kronemer, KA
    Kraus, RA
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2004, 182 (04) : 37 - 37
  • [36] Improvement of radiotherapy treatment delivery accuracy using an electronic portal imaging device
    Dirkx, M. L. P.
    de Boer, J. C. J.
    Heijmen, B. J. M.
    RADIATION PROTECTION DOSIMETRY, 2006, 121 (01) : 70 - 79
  • [37] Image Quality and Information Parameters of Electronic Portal Imaging Devices
    Tzomakas, Marios K.
    Peppa, Vasiliki
    Alexiou, Antigoni
    Karakatsanis, Georgios
    Episkopakis, Anastasios
    Michail, Christos
    Valais, Ioannis
    Fountos, George
    Kalyvas, Nektarios
    Kandarakis, Ioannis S.
    APPLIED SCIENCES-BASEL, 2024, 14 (22):
  • [38] INTRAORAL COMPUTED RADIOGRAPHY USING THE FUJI COMPUTED RADIOGRAPHY IMAGING PLATE - CORRELATION BETWEEN IMAGE QUALITY AND READING CONDITION
    KASHIMA, I
    SAKURAI, T
    MATSUKI, T
    NAKAMURA, K
    AOKI, H
    ISHII, M
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1994, 78 (02): : 239 - 246
  • [39] Filmless Quality Assurance for Linear Accelerator with Electronic Portal Image Device
    Chen, H.
    Jacob, D.
    Simpson, L.
    Chen, W.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [40] Evaluation of Volumetric Losses during Radiation Therapy Using Image Guidance of Electronic Portal Imaging Device
    Senick, S.
    Chang, Z.
    MEDICAL PHYSICS, 2010, 37 (06) : 3182 - +