Development of a Radiotherapy System Based on 6 MeV Linac and Cone-Beam Computer Tomograph

被引:0
|
作者
I. I. Rod’ko
G. A. Sarychev
P. V. Balakirev
T. V. Bondarenko
I. L. Dergacheva
A. S. Evteev
S. N. Kovalev
S. A. Koloskov
T. A. Krylova
T. K. Lobzhanidze
S. A. Polikhov
V. P. Smirnov
G. B. Sharkov
G. E. Gorlachev
I. V. Gulidov
S. A. Ivanov
A. D. Kaprin
Yu. S. Romanko
E. V. Khmelevskii
L. Yu. Ovchinnikova
V. I. Shvedunov
N. V. Shvedunov
D. V. Cherednichenko
机构
[1] National Research Nuclear University MEPhI (Moscow Engineering Physics Institute),Laboratory of Electron Accelerators (LEU MGU)
[2] Research Institute of Technical Physics and Automation (NIITFA),undefined
[3] Radiation-Oncological Intelligent Systems and Services,undefined
[4] National Medical Research Center of Radiology (NMITS Radiology),undefined
[5] Lomonosov Moscow State University,undefined
[6] Rusatom Healthcare,undefined
来源
Atomic Energy | 2019年 / 125卷
关键词
D O I
暂无
中图分类号
学科分类号
摘要
A system currently under development for remote radiotherapy based on a 6 MeV linac and cone-beam computer tomograph is presented. Its distinguishing design features and solutions are described: compact 5-cm wavelength electron accelerator, solid-state modulator, visualization in the bremsstrahlung beam with low nominal energy 2.5 MeV, bremsstrahlung beam without a compensating filter, cone-beam computer tomography, multi-leaf collimator, adaptive radiotherapy, and a therapeutic table with six degrees of freedom. The system is compared with foreign analogs.
引用
收藏
页码:333 / 337
页数:4
相关论文
共 50 条
  • [41] Shading correction algorithm for improvement of cone-beam CT images in radiotherapy
    Marchant, T. E.
    Moore, C. J.
    Rowbottom, C. G.
    MacKay, R. I.
    Williams, P. C.
    PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (20): : 5719 - 5733
  • [42] Image Quality QA for Three Radiotherapy Cone-Beam CT Systems
    Doemer, A.
    Perera, H.
    Gingold, E.
    Liu, H.
    Fu, L.
    Harrison, A.
    Yu, Y.
    Xiao, Y.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [43] Adaptive Radiotherapy Via Deep Learning-Based Quantitative Cone-Beam CT Imaging
    Wan, L.
    Wu, H.
    Xu, S.
    Sun, B.
    Zhao, W.
    MEDICAL PHYSICS, 2022, 49 (06) : E383 - E383
  • [44] Cone-beam computed tomography in hypofractionated stereotactic radiotherapy for brain metastases
    Ingrosso, Gianluca
    Miceli, Roberto
    Fedele, Dahlia
    Ponti, Elisabetta
    Benassi, Michaela
    Barbarino, Rosaria
    Di Murro, Luana
    Giudice, Emilia
    Santarelli, Federico
    Santoni, Riccardo
    RADIATION ONCOLOGY, 2012, 7
  • [45] Cone-beam computed tomography in hypofractionated stereotactic radiotherapy for brain metastases
    Gianluca Ingrosso
    Roberto Miceli
    Dahlia Fedele
    Elisabetta Ponti
    Michaela Benassi
    Rosaria Barbarino
    Luana Di Murro
    Emilia Giudice
    Federico Santarelli
    Riccardo Santoni
    Radiation Oncology, 7
  • [46] Prostate Image-Guided Radiotherapy by Megavolt Cone-Beam CT
    Zucca, Sergio
    Carau, Barbara
    Solla, Ignazio
    Garibaldi, Elisabetta
    Farace, Paolo
    Lay, Giancarlo
    Meleddu, Gianfranco
    Gabriele, Pietro
    STRAHLENTHERAPIE UND ONKOLOGIE, 2011, 187 (08) : 473 - 478
  • [47] Cone-beam CT: Applications in image-guided external beam radiotherapy and brachytherapy
    Jaffray, DA
    Siewerdsen, JH
    Edmundson, GE
    Wong, JW
    Martinez, A
    PROCEEDINGS OF THE 22ND ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4, 2000, 22 : 2044 - 2044
  • [48] Development of a pulsing system with the linac based slow positron beam
    Tashiro, M
    Honda, Y
    Yamaguchi, T
    Pujari, PK
    Kimura, N
    Kozawa, T
    Tagawa, S
    POSITRON ANNIHILATION - ICPA-12, 2001, 363-3 : 664 - 666
  • [49] Cone-beam CT based image-guidance for extracranial stereotactic radiotherapy of intrapulmonary tumors
    Guckenberger, Matthias
    Meyer, Juergen
    Wilbert, Juergen
    Baier, Kurt
    Mueller, Gerd
    Wulf, Joern
    Flentje, Michael
    ACTA ONCOLOGICA, 2006, 45 (07) : 897 - 906
  • [50] NSRL 200 MeV Linac beam energy stabilization system
    Huang, G.R.
    Pei, Y.J.
    Dong, S.
    He Jishu/Nuclear Techniques, 2001, 24 (03):