Cone-beam CT based image-guidance for extracranial stereotactic radiotherapy of intrapulmonary tumors

被引:99
|
作者
Guckenberger, Matthias
Meyer, Juergen
Wilbert, Juergen
Baier, Kurt
Mueller, Gerd
Wulf, Joern
Flentje, Michael
机构
[1] Univ Wurzburg, Dept Radiat Oncol, D-97080 Wurzburg, Germany
[2] Lindenhofspital, Dept Radiooncol, Bern, Switzerland
关键词
D O I
10.1080/02841860600904839
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Cone-beam CT ( CB-CT) based image-guidance was evaluated for extracranial stereotactic radiotherapy of intrapulmonary tumors. A total of 21 patients (25 lesions: prim. NSCLC n = 6; pulmonary metastases n = 19) were treated with stereotactic radiotherapy (1 to 8 fractions). Prior to every fraction a CB-CT was acquired in treatment position, errors between planned and actual tumor position were measured and corrected. Intra- and inter-observer variability of manual evaluation of tumor position error was investigated and this manual method was compared with automatic image registration. Based on CB-CTs from 66 fractions the discrepancy (3-D vector) between planned and actual tumor position was 7.7 mm +/- 1.3 mm. Tumor position error relative to the bony anatomy was 5.3 mm +/- 1.2 mm, the correlation between bony anatomy and tumor position was poor. Intra- observer and inter-observer variability of manual evaluation of tumor position error was 0.9 mm +/- 0.8 mm and 2.3 mm +/- 1.1 mm, respectively. Automatic image registration showed highly reproducible results (< 1 mm). However, compared with manual registration a systematic error was found in direction of predominant tumor breathing motion (2.5 mm vs 1.4 mm). Image-guidance using CB-CT was validated for high precision radiotherapy of intrapulmonary tumors. It was shown that both the planning reference and the verification image study have to consider tumor breathing motion.
引用
收藏
页码:897 / 906
页数:10
相关论文
共 50 条
  • [1] Cone-beam CT based image-guidance for hypofractionated radiotherapy of intrapulmonary lesions - Evaluation of benefits and limitations
    Guckenberger, M.
    Richter, A.
    Wilbert, J.
    Meyer, J.
    Baier, K.
    Wulf, J.
    Flentje, M.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03): : S154 - S154
  • [2] Cone-beam CT: Applications in image-guidance
    Jaffray, DA
    [J]. RADIOTHERAPY AND ONCOLOGY, 2006, 78 : S12 - S12
  • [3] Initial clinical experience with extracranial stereotactic lung radiotherapy: Advantages of cone-beam CT image-guidance over stereotactic body frame immobilization alone
    Grills, I. S.
    Hugo, G.
    Chao, K.
    Kestin, L.
    Wloch, J.
    Martinez, A.
    Yan, D.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03): : S469 - S470
  • [4] Image quality of cone beam CT used as image-guidance for pelvic Stereotactic Ablative Radiotherapy
    Slevin, F.
    Beasley, M.
    Needham, A.
    Lilley, J.
    Speight, R.
    Murray, L. J.
    Henry, A. M.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S303 - S303
  • [5] Cone beam CT for daily image-guidance in prostate radiotherapy
    Wiltshire, K. L.
    White, E. A.
    Moseley, D. J.
    Jaffiray, D. A.
    Warde, P.
    Catton, C.
    [J]. EJC SUPPLEMENTS, 2005, 3 (02): : 235 - 235
  • [6] The Effect of Cone-Beam CT Image-Guidance Strategies on the Delivered Dose for Spine Metastases Radiotherapy
    Jia, C.
    Zhao, B.
    Gao, X. S.
    Bai, Y.
    Shang, Z.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2021, 111 (03): : E541 - E542
  • [7] Stereotactic radiosurgery for intradural spine tumors using cone-beam CT image guidance
    Monserrate, Andres
    Zussman, Benjamin
    Ozpinar, Alp
    Niranjan, Ajay
    Flickinger, John C.
    Gerszten, Peter C.
    [J]. NEUROSURGICAL FOCUS, 2017, 42 (01)
  • [8] Optimal Image-Guidance Scenario With Cone-Beam Computed Tomography in Conventionally Fractionated Radiotherapy for Lung Tumors
    Yeung, Anamaria R.
    Li, Jonathan
    Shi, Wenyin
    Newlin, Heather
    Morris, Christopher G.
    Samant, Sanjiv
    Saito, Anneyuko
    Chvetsov, Alexei
    Liu, Chihray
    Palta, Jatinder
    Olivier, Kenneth
    [J]. AMERICAN JOURNAL OF CLINICAL ONCOLOGY-CANCER CLINICAL TRIALS, 2010, 33 (03): : 276 - 280
  • [9] Image-Guidance Using Cone-Beam CT for Stereotactic Body Radiotherapy (SBRT) of Lung Cancer Patients: Bony Alignment Or Soft Tissue Alignment?
    Wang, L.
    Turaka, A.
    Meyer, J.
    Spoka, D.
    Jin, L.
    Fan, J.
    Ma, C.
    [J]. MEDICAL PHYSICS, 2012, 39 (06) : 3657 - 3657
  • [10] Daily cone-beam CT (CBCT)-based image guidance for stereotactic lung radiotherapy improves target dose delivery
    Galerani, A. P.
    Grills, I. S.
    Kestin, L. L.
    Yan, D.
    Mohammed, N.
    Suen, A. W.
    Chao, K. K.
    Martinez, A. A.
    Hugo, G. D.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (01): : S632 - S632