Cone-beam CT based image-guidance for extracranial stereotactic radiotherapy of intrapulmonary tumors

被引:99
|
作者
Guckenberger, Matthias
Meyer, Juergen
Wilbert, Juergen
Baier, Kurt
Mueller, Gerd
Wulf, Joern
Flentje, Michael
机构
[1] Univ Wurzburg, Dept Radiat Oncol, D-97080 Wurzburg, Germany
[2] Lindenhofspital, Dept Radiooncol, Bern, Switzerland
关键词
D O I
10.1080/02841860600904839
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Cone-beam CT ( CB-CT) based image-guidance was evaluated for extracranial stereotactic radiotherapy of intrapulmonary tumors. A total of 21 patients (25 lesions: prim. NSCLC n = 6; pulmonary metastases n = 19) were treated with stereotactic radiotherapy (1 to 8 fractions). Prior to every fraction a CB-CT was acquired in treatment position, errors between planned and actual tumor position were measured and corrected. Intra- and inter-observer variability of manual evaluation of tumor position error was investigated and this manual method was compared with automatic image registration. Based on CB-CTs from 66 fractions the discrepancy (3-D vector) between planned and actual tumor position was 7.7 mm +/- 1.3 mm. Tumor position error relative to the bony anatomy was 5.3 mm +/- 1.2 mm, the correlation between bony anatomy and tumor position was poor. Intra- observer and inter-observer variability of manual evaluation of tumor position error was 0.9 mm +/- 0.8 mm and 2.3 mm +/- 1.1 mm, respectively. Automatic image registration showed highly reproducible results (< 1 mm). However, compared with manual registration a systematic error was found in direction of predominant tumor breathing motion (2.5 mm vs 1.4 mm). Image-guidance using CB-CT was validated for high precision radiotherapy of intrapulmonary tumors. It was shown that both the planning reference and the verification image study have to consider tumor breathing motion.
引用
收藏
页码:897 / 906
页数:10
相关论文
共 50 条
  • [31] IMPROVEMENT OF TARGET COVERAGE IN RADICAL LUNG RADIOTHERAPY USING IMAGE GUIDANCE CONE-BEAM CT (CBCT)
    Lavoie, C.
    Higgins, J.
    Bissonnette, J. -P.
    Brade, A.
    Cho, J.
    Hope, A.
    Sun, A.
    Le, L. W.
    Bezjak, A.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S4 - S4
  • [32] Cone-beam CT for radiotherapy applications
    Cho, P.S.
    Johnson, R.H.
    Griffin, T.W.
    [J]. 1863, Institute of Physics Publishing Ltd, Bristol, Engl (40):
  • [33] CONE-BEAM CT FOR RADIOTHERAPY APPLICATIONS
    CHO, PS
    JOHNSON, RH
    GRIFFIN, TW
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1995, 40 (11): : 1863 - 1883
  • [34] Clinical startup of cone-beam CT-guided cranial stereotactic radiotherapy
    Praestegaard, L.
    Elstrom, U. V.
    Petersen, J.
    Poulsen, P.
    Schulz, H.
    Seiersen, K.
    Traberg, A.
    Hoyer, M.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S289 - S290
  • [35] On the accuracy of cone-beam CT and stereoscopic x-ray image guidance for radiotherapy of vertebral tumors: An intra-institutional comparison
    Bogner, J.
    Bednarz, G.
    Downes-Philips, B.
    Galvin, J.
    Georg, D.
    Andrews, D.
    Curran, W.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03): : S639 - S639
  • [36] Image-guided body stereotactic radiotherapy using cone-beam computer tomography for treatment of spinal tumors
    Wang, C.
    Shin, A.
    Wang, H.
    Chang, E.
    [J]. MEDICAL PHYSICS, 2007, 34 (06) : 2377 - 2377
  • [37] Determination of Stereotactic Shifts for Frame-Based Stereotactic Radiosurgery Using Cone-Beam Computed Tomography Image Guidance
    Hadley, A.
    Seneviratne, D.
    Serago, C. F.
    Herchko, S.
    Welch, E.
    Peterson, J. L.
    Trifiletti, D. M.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2019, 105 (01): : E763 - E763
  • [38] Megavoltage and Kilovoltage Cone-Beam Computed Tomography Image Guidance for Lung Radiotherapy
    Vlad, M.
    Sixel, K.
    Kosowan, S.
    Hart, M.
    Iqbal, F.
    El-Mallah, M.
    Vandermeer, A.
    [J]. MEDICAL PHYSICS, 2011, 38 (06)
  • [39] Cone-beam CT (CBCT) image-guided radiotherapy (IGRT) significantly reduces margins required for stereotactic
    Grills, I.
    Kestin, L.
    Yan, D.
    Chao, K.
    Wloch, J.
    Hugo, G.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S62 - S62
  • [40] Image Quality QA for Three Radiotherapy Cone-Beam CT Systems
    Doemer, A.
    Perera, H.
    Gingold, E.
    Liu, H.
    Fu, L.
    Harrison, A.
    Yu, Y.
    Xiao, Y.
    [J]. MEDICAL PHYSICS, 2009, 36 (06)