Development of a Radiotherapy System Based on 6 MeV Linac and Cone-Beam Computer Tomograph

被引:0
|
作者
I. I. Rod’ko
G. A. Sarychev
P. V. Balakirev
T. V. Bondarenko
I. L. Dergacheva
A. S. Evteev
S. N. Kovalev
S. A. Koloskov
T. A. Krylova
T. K. Lobzhanidze
S. A. Polikhov
V. P. Smirnov
G. B. Sharkov
G. E. Gorlachev
I. V. Gulidov
S. A. Ivanov
A. D. Kaprin
Yu. S. Romanko
E. V. Khmelevskii
L. Yu. Ovchinnikova
V. I. Shvedunov
N. V. Shvedunov
D. V. Cherednichenko
机构
[1] National Research Nuclear University MEPhI (Moscow Engineering Physics Institute),Laboratory of Electron Accelerators (LEU MGU)
[2] Research Institute of Technical Physics and Automation (NIITFA),undefined
[3] Radiation-Oncological Intelligent Systems and Services,undefined
[4] National Medical Research Center of Radiology (NMITS Radiology),undefined
[5] Lomonosov Moscow State University,undefined
[6] Rusatom Healthcare,undefined
来源
Atomic Energy | 2019年 / 125卷
关键词
D O I
暂无
中图分类号
学科分类号
摘要
A system currently under development for remote radiotherapy based on a 6 MeV linac and cone-beam computer tomograph is presented. Its distinguishing design features and solutions are described: compact 5-cm wavelength electron accelerator, solid-state modulator, visualization in the bremsstrahlung beam with low nominal energy 2.5 MeV, bremsstrahlung beam without a compensating filter, cone-beam computer tomography, multi-leaf collimator, adaptive radiotherapy, and a therapeutic table with six degrees of freedom. The system is compared with foreign analogs.
引用
收藏
页码:333 / 337
页数:4
相关论文
共 50 条
  • [31] Quantitative Cone-Beam CT Imaging in Radiotherapy: Parallel Computation and Comprehensive Evaluation on the TrueBeam System
    Liang, Xiaokun
    Jiang, Yangkang
    Xie, Yaoqin
    Niu, Tianye
    IEEE ACCESS, 2019, 7 : 66226 - 66233
  • [32] The prevalence of Haller's Cells in Cone-beam Computer Tomography
    Razavi, Mahshid
    Mohebiniya, Maryam
    Moridi, Milad
    MEDICAL SCIENCE, 2020, 24 (103) : 1500 - 1506
  • [33] DEVELOPMENT OF A 3D CT SCANNER WITH A CONE-BEAM AND VIDEOFLUOROSCOPIC SYSTEM
    ENDO, M
    SATOH, K
    OKAZAKI, T
    HATTORI, Y
    KOBAYASHI, S
    JIMBO, M
    RADIOLOGY, 1995, 197 : 292 - 292
  • [34] Multi-pass approach to reduce cone-beam artifacts in a circular orbit cone-beam CT system
    Han, Chulhee
    Baek, Jongduk
    OPTICS EXPRESS, 2019, 27 (07) : 10108 - 10126
  • [35] Dual-energy approach to reduce cone-beam artefacts in a circular orbit cone-beam CT system
    Han, C.
    Baek, J.
    ELECTRONICS LETTERS, 2020, 56 (13) : 648 - 650
  • [36] Image-guided body stereotactic radiotherapy using cone-beam computer tomography for treatment of spinal tumors
    Wang, C.
    Shin, A.
    Wang, H.
    Chang, E.
    MEDICAL PHYSICS, 2007, 34 (06) : 2377 - 2377
  • [37] MR-Linac is a better choice for adaptive therapy compared to cone-beam CT
    Alongi, Filippo
    Zheng, Dandan
    Das, Indra J.
    MEDICAL PHYSICS, 2025,
  • [38] Application of a KV cone beam equipment on a Siemens linac for image guided radiotherapy
    Tücking, T
    Nill, S
    Hesse, B
    Bendl, R
    Oelfke, U
    RADIOTHERAPY AND ONCOLOGY, 2004, 73 : S51 - S51
  • [39] A review of cone-beam CT applications for adaptive radiotherapy of prostate cancer
    Posiewnik, M.
    Piotrowski, T.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 59 : 13 - 21
  • [40] A cone-beam megavoltage CT scanner for treatment verification in conformal radiotherapy
    Mosleh-Shirazi, MA
    Evans, PM
    Swindell, W
    Webb, S
    Partridge, M
    RADIOTHERAPY AND ONCOLOGY, 1998, 48 (03) : 319 - 328