Reducing absorbed dose to eye lenses in head CT examinations: the effect of bismuth shielding

被引:0
|
作者
Alberto Ciarmatori
L. Nocetti
G. Mistretta
G. Zambelli
T. Costi
机构
[1] Az. Ospedaliero – Universitaria di Modena- Policlinico,Medical Physics Department
[2] Alma Mater Studiorum University,Post Graduate School in Medical Physics
[3] Lavoro e Ambiente Srl,undefined
关键词
Computed tomography; Eye lens; Bismuth shielding; Dose reduction; Image quality;
D O I
暂无
中图分类号
学科分类号
摘要
The eye lens is considered to be among the most radiosensitive human tissues. Brain CT scans may unnecessarily expose it to radiation even if the area of clinical interest is far from the eyes. The aim of this study is to implement a bismuth eye lens shielding system for Head-CT acquisitions in these cases. The study is focused on the assessment of the dosimetric characteristics of the shielding system as well as on its effect on image quality. The shielding system was tested in two set-ups which differ for distance (“contact” and “4 cm” Set up respectively). Scans were performed on a CTDI phantom and an anthropomorphic phantom. A reference set up without shielding system was acquired to establish a baseline. Image quality was assessed by signal (not HU converted), noise and contrast-to-noise ratio (CNR) evaluation. The overall dose reduction was evaluated by measuring the CTDIvol while the eye lens dose reduction was assessed by placing thermoluminescent dosimeters (TLDs) on an anthropomorphic phantom. The image quality analysis exhibits the presence of an artefact that mildly increases the CT number up to 3 cm below the shielding system. Below the artefact, the difference of the Signal and the CNR are negligible between the three different set-ups. Regarding the CTDI, the analysis demonstrates a decrease by almost 12 % (in the “contact” set-up) and 9 % (in the “4 cm” set-up). TLD measurements exhibit an eye lens dose reduction by 28.5 ± 5 and 21.1 ± 5 % respectively at the “contact” and the “4 cm” distance. No relevant artefact was found and image quality was not affected by the shielding system. Significant dose reductions were measured. These features make the shielding set-up useful for clinical implementation in both studied positions.
引用
收藏
页码:583 / 589
页数:6
相关论文
共 50 条
  • [31] AN INVESTIGATION INTO CT RADIATION DOSE VARIATIONS FOR HEAD EXAMINATIONS ON MATCHED EQUIPMENT
    Zarb, Francis
    Foley, Shane
    Holm, Susanne
    Toomey, Rachel
    Evanoff, Michael G.
    Rainford, Louise
    RADIATION PROTECTION DOSIMETRY, 2016, 172 (04) : 466 - 474
  • [32] Determining Size-Specific Dose Estimates for Head CT Examinations
    Hardy, A.
    Bostani, M.
    Zankl, M.
    McCollough, C.
    Cagnon, C.
    McNitt-Gray, M.
    MEDICAL PHYSICS, 2017, 44 (06) : 3314 - 3315
  • [33] Real-time estimation of dose reduction for pediatric CT using bismuth shielding
    Lai, Nan-Ku
    Liao, Ying-Lan
    Chen, Tuo-Rong
    Tyan, Yu-Sheng
    Tsai, Hui-Yu
    RADIATION MEASUREMENTS, 2011, 46 (12) : 2039 - 2043
  • [34] Fabrication of Head Phantom to Investigate the Effect of Heterogeneity on the Absorbed Dose in Radiotherapy
    P. Rezaeian
    L. Teimoori Khandan
    H. Torabi
    S. Kashian
    Iranian Journal of Science and Technology, Transactions A: Science, 2022, 46 : 1295 - 1300
  • [35] Fabrication of Head Phantom to Investigate the Effect of Heterogeneity on the Absorbed Dose in Radiotherapy
    Rezaeian, P.
    Khandan, L. Teimoori
    Torabi, H.
    Kashian, S.
    IRANIAN JOURNAL OF SCIENCE AND TECHNOLOGY TRANSACTION A-SCIENCE, 2022, 46 (04): : 1295 - 1300
  • [36] OPTIMAL CT SETTINGS FOR HEAD IMAGING IN THE PEDIATRIC-PATIENT - AN ANALYSIS OF ABSORBED DOSE
    DAMILAKIS, JE
    TSOUDEROS, JG
    EUROPEAN JOURNAL OF RADIOLOGY, 1989, 9 (01) : 48 - 50
  • [37] The efficiency of lead and non-lead shielding on breast dose in head CT
    Trozic, Sejla
    Mekis, Nejc
    Zalokar, Nika
    JOURNAL OF RADIOLOGICAL PROTECTION, 2020, 40 (03) : 816 - 826
  • [38] Bismuth Shields Vs. MAs Reduction for Decreased Radiation Dose to Breasts in CT Examinations
    Goodsitt, M.
    Christodoulou, E.
    Larson, S.
    Kazerooni, E.
    Bogot, N.
    Frank, L.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [39] Development of age-specific Japanese head phantoms for dose evaluation in paediatric head CT examinations
    Yamauchi-Kawaura, C.
    Fujii, K.
    Akahane, K.
    Yamauchi, M.
    Narai, K.
    Aoyama, T.
    Katsu, T.
    Obara, S.
    Imai, K.
    Ikeda, M.
    RADIATION PROTECTION DOSIMETRY, 2015, 163 (02) : 188 - 201
  • [40] Organ-based tube current modulation and bismuth eye shielding in pediatric head computed tomography
    Markart, Stefan
    Fischer, Tim S.
    Wildermuth, Simon
    Dietrich, Tobias J.
    Alkadhi, Hatem
    Leschka, Sebastian
    Guesewell, Sabine
    Ditchfield, Michael R.
    Oezden, Ismail
    Lutters, Gerd
    Waelti, Stephan L.
    PEDIATRIC RADIOLOGY, 2022, 52 (13) : 2584 - 2594