Reducing absorbed dose to eye lenses in head CT examinations: the effect of bismuth shielding

被引:0
|
作者
Alberto Ciarmatori
L. Nocetti
G. Mistretta
G. Zambelli
T. Costi
机构
[1] Az. Ospedaliero – Universitaria di Modena- Policlinico,Medical Physics Department
[2] Alma Mater Studiorum University,Post Graduate School in Medical Physics
[3] Lavoro e Ambiente Srl,undefined
关键词
Computed tomography; Eye lens; Bismuth shielding; Dose reduction; Image quality;
D O I
暂无
中图分类号
学科分类号
摘要
The eye lens is considered to be among the most radiosensitive human tissues. Brain CT scans may unnecessarily expose it to radiation even if the area of clinical interest is far from the eyes. The aim of this study is to implement a bismuth eye lens shielding system for Head-CT acquisitions in these cases. The study is focused on the assessment of the dosimetric characteristics of the shielding system as well as on its effect on image quality. The shielding system was tested in two set-ups which differ for distance (“contact” and “4 cm” Set up respectively). Scans were performed on a CTDI phantom and an anthropomorphic phantom. A reference set up without shielding system was acquired to establish a baseline. Image quality was assessed by signal (not HU converted), noise and contrast-to-noise ratio (CNR) evaluation. The overall dose reduction was evaluated by measuring the CTDIvol while the eye lens dose reduction was assessed by placing thermoluminescent dosimeters (TLDs) on an anthropomorphic phantom. The image quality analysis exhibits the presence of an artefact that mildly increases the CT number up to 3 cm below the shielding system. Below the artefact, the difference of the Signal and the CNR are negligible between the three different set-ups. Regarding the CTDI, the analysis demonstrates a decrease by almost 12 % (in the “contact” set-up) and 9 % (in the “4 cm” set-up). TLD measurements exhibit an eye lens dose reduction by 28.5 ± 5 and 21.1 ± 5 % respectively at the “contact” and the “4 cm” distance. No relevant artefact was found and image quality was not affected by the shielding system. Significant dose reductions were measured. These features make the shielding set-up useful for clinical implementation in both studied positions.
引用
收藏
页码:583 / 589
页数:6
相关论文
共 50 条
  • [21] MOSFET dosimetry for radiation dose assessment of bismuth shielding of the eye in children
    Mukundan, Srinivasan, Jr.
    Wang, Page Inman
    Frush, Donald P.
    Yoshizumi, Terry
    Marcus, Jeffrey
    Kloeblen, Emily
    Moore, Meredith
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 188 (06) : 1648 - 1650
  • [22] Discrepancy between absorbed dose estimated from phantom measurements and from estimates using data on individual head sizes in head CT examinations
    Adliene, D.
    Mockeviciene, S.
    RADIATION PROTECTION DOSIMETRY, 2010, 139 (1-3) : 186 - 190
  • [23] Absorbed dose differences between twin fetuses for pregnancy patients in CT examinations
    Qu, Shuiyin
    Jia, Haoran
    Zaidi, Habib
    Xie, Tianwu
    MEDICAL PHYSICS, 2025, 52 (04) : 2632 - 2643
  • [24] Reducing the radiation dose to the eye lens region during CT brain examination: the potential beneficial effect of the combined use of bolus and a bismuth shield
    Lai, C. W. -K.
    Cheung, H. -Y.
    Chan, T. -P.
    Wong, T. H.
    RADIOPROTECTION, 2015, 50 (03) : 195 - 201
  • [25] Reducing Eye Lens Dose during Brain Perfusion CT Examinations by Moving the Scan Location or Tilting the Gantry Angle
    Zhang, D.
    Cagnon, C.
    DeMarco, J.
    Zankl, M.
    Turner, A.
    Khatonabadi, M.
    McNitt-Gray, M.
    MEDICAL PHYSICS, 2010, 37 (06) : 3109 - +
  • [26] Reducing radiation dose associated with pediatric CT by decreasing unnecessary examinations
    Donnelly, LF
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 184 (02) : 655 - 657
  • [27] Radiation dose and risk to the lens of the eye during CT examinations of the brain
    Poon, Rebekah
    Badawy, Mohamed K.
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2019, 63 (06) : 786 - 794
  • [28] IRRADIATION DOSE TO THE LENS OF THE EYE DURING CT OF THE HEAD
    LUND, E
    HALABURT, H
    NEURORADIOLOGY, 1982, 22 (04) : 181 - 184
  • [29] Bismuth Breast Shielding and its Effect on Calcium Score and Dose
    Ciancibello, L.
    Gilkeson, R.
    Fei, B.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 192 (05)
  • [30] DOSE REDUCTION IN CT USING BISMUTH SHIELDING: MEASUREMENTS AND MONTE CARLO SIMULATIONS
    Chang, Kyung-Hwan
    Lee, Wonho
    Choo, Dong-Myung
    Lee, Choon-Sik
    Kim, Youhyun
    RADIATION PROTECTION DOSIMETRY, 2010, 138 (04) : 382 - 388