Reducing absorbed dose to eye lenses in head CT examinations: the effect of bismuth shielding

被引:0
|
作者
Alberto Ciarmatori
L. Nocetti
G. Mistretta
G. Zambelli
T. Costi
机构
[1] Az. Ospedaliero – Universitaria di Modena- Policlinico,Medical Physics Department
[2] Alma Mater Studiorum University,Post Graduate School in Medical Physics
[3] Lavoro e Ambiente Srl,undefined
关键词
Computed tomography; Eye lens; Bismuth shielding; Dose reduction; Image quality;
D O I
暂无
中图分类号
学科分类号
摘要
The eye lens is considered to be among the most radiosensitive human tissues. Brain CT scans may unnecessarily expose it to radiation even if the area of clinical interest is far from the eyes. The aim of this study is to implement a bismuth eye lens shielding system for Head-CT acquisitions in these cases. The study is focused on the assessment of the dosimetric characteristics of the shielding system as well as on its effect on image quality. The shielding system was tested in two set-ups which differ for distance (“contact” and “4 cm” Set up respectively). Scans were performed on a CTDI phantom and an anthropomorphic phantom. A reference set up without shielding system was acquired to establish a baseline. Image quality was assessed by signal (not HU converted), noise and contrast-to-noise ratio (CNR) evaluation. The overall dose reduction was evaluated by measuring the CTDIvol while the eye lens dose reduction was assessed by placing thermoluminescent dosimeters (TLDs) on an anthropomorphic phantom. The image quality analysis exhibits the presence of an artefact that mildly increases the CT number up to 3 cm below the shielding system. Below the artefact, the difference of the Signal and the CNR are negligible between the three different set-ups. Regarding the CTDI, the analysis demonstrates a decrease by almost 12 % (in the “contact” set-up) and 9 % (in the “4 cm” set-up). TLD measurements exhibit an eye lens dose reduction by 28.5 ± 5 and 21.1 ± 5 % respectively at the “contact” and the “4 cm” distance. No relevant artefact was found and image quality was not affected by the shielding system. Significant dose reductions were measured. These features make the shielding set-up useful for clinical implementation in both studied positions.
引用
收藏
页码:583 / 589
页数:6
相关论文
共 50 条
  • [41] Effectiveness of the air-gap method for reducing radiation dose in neonate CT examinations
    Masuda, Takanori
    Funama, Yoshinori
    Nakaura, Takeshi
    Sato, Tomoyasu
    Oku, Takayuki
    Ono, Atsushi
    Awai, Kazuo
    RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2025, 18 (01) : 293 - 299
  • [42] Organ-based tube current modulation and bismuth eye shielding in pediatric head computed tomography
    Stefan Markart
    Tim S. Fischer
    Simon Wildermuth
    Tobias J. Dietrich
    Hatem Alkadhi
    Sebastian Leschka
    Sabine Guesewell
    Michael R. Ditchfield
    Ismail Oezden
    Gerd Lutters
    Stephan L. Waelti
    Pediatric Radiology, 2022, 52 : 2584 - 2594
  • [43] Head CT: Image quality improvement of posterior fossa and radiation dose reduction with ASiR - comparative studies of CT head examinations
    Maciej Guziński
    Łukasz Waszczuk
    Marek J. Sąsiadek
    European Radiology, 2016, 26 : 3691 - 3696
  • [44] Head CT: Image quality improvement of posterior fossa and radiation dose reduction with ASiR - comparative studies of CT head examinations
    Guzinski, Maciej
    Waszczuk, Lukasz
    Sasiadek, Marek J.
    EUROPEAN RADIOLOGY, 2016, 26 (10) : 3691 - 3696
  • [45] Frequency and Diagnostic Implications of Image Artifacts by Eye-Lens Shielding in Head CT
    Schmidt, Stefan A.
    Gruenke, Teresa
    Beer, Meinrad
    Wunderlich, Arthur P.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2019, 212 (03) : 607 - 613
  • [46] COMPARISON OF ORGAN-BASED TUBE CURRENT MODULATION AND BISMUTH SHIELDING IN CHEST CT: EFFECT ON THE IMAGE QUALITY AND THE PATIENT DOSE
    Kotiaho, Antti
    Manninen, Anna-Leena
    Nikkinen, Juha
    Nieminen, Miika Tapio
    RADIATION PROTECTION DOSIMETRY, 2019, 185 (01) : 50 - 56
  • [47] THE SIZE-SPECIFIC DOSE ESTIMATE OF PAEDIATRIC HEAD CT EXAMINATIONS FOR VARIOUS PROTOCOLS
    Fahmi, Arif
    Anam, Choirul
    Ali, Mohd Hanafi
    RADIATION PROTECTION DOSIMETRY, 2020, 188 (04) : 522 - 528
  • [48] Assessment of organ dose and image quality in head and chest CT examinations: a phantom study
    Gharbi, S.
    Labidi, S.
    Mars, M.
    Chelli, M.
    Meftah, S.
    Ladeb, M. F.
    JOURNAL OF RADIOLOGICAL PROTECTION, 2018, 38 (02) : 807 - 818
  • [49] Assessment of dose reduction and image quality by barium composite shielding in head and chest CT
    Lee, Jong-Woong
    Kweon, Dae Cheol
    RADIATION EFFECTS AND DEFECTS IN SOLIDS, 2020, 175 (9-10): : 809 - 826
  • [50] DIRECT MEASUREMENTS OF SKIN, EYE LENS AND THYROID DOSE DURING PEDIATRIC BRAIN CT EXAMINATIONS
    Ploussi, Agapi
    Stathopoulos, Ioannis
    Syrgiamiotis, Vasileios
    Makri, Triantafillia
    Hatzigiorgi, Christiana
    Platoni, Kalliopi
    Carinou, Eleftheria
    Efstathopoulos, Efstathios P.
    RADIATION PROTECTION DOSIMETRY, 2018, 179 (03) : 199 - 205