Advantages of mesh tallying in MCNPX for 3D dose calculations in radiotherapy

被引:0
|
作者
I. Jabbari
M. Shahriari
S. M. R. Aghamiri
S. Monadi
机构
[1] Shahid Beheshti University,Department of Medical Radiation Engineering
[2] Isfahan Milad Hospital,Department of Radiation Oncology
关键词
Monte Carlo; MCNPX; Mesh tally; 3D dose calculation; Treatment planning;
D O I
暂无
中图分类号
学科分类号
摘要
The energy deposition mesh tally option of MCNPX Monte Carlo code is very useful for 3-Dimentional (3D) dose calculations. In this study, the 3D dose calculation was done for CT-based Monte Carlo treatment planning in which the energy deposition mesh tally were superimposed on merged voxel model. The results were compared with those of obtained from the common energy deposition (*F8) tally method for all cells of non-merged voxel model. The results of these two tallies and their respective computational times are compared, and the advantages of the proposed method are discussed. For this purpose, a graphical user interface (GUI) application was developed for reading CT slice data of patient, creating voxelized model of patient, optionally merging adjacent cells with the same material to reduce the total number of cells, reading beam configuration from commercial treatment planning system transferred in DICOM-RT format, and showing the isodose distribution on the CT images. To compare the results of Monte Carlo calculated and TiGRT planning system (LinaTech LLC, USA), treatment head of the Siemens ONCOR Impression accelerator was also simulated and the phase-space data on the scoring plane just above the Y-jaws was created and used. The results for a real prostate intensity-modulated radiation therapy (IMRT) plan showed that the proposed method was fivefold faster while the precision was almost the same.
引用
收藏
页码:831 / 837
页数:6
相关论文
共 50 条
  • [1] Advantages of mesh tallying in MCNPX for 3D dose calculations in radiotherapy
    Jabbari, I.
    Shahriari, M.
    Aghamiri, S. M. R.
    Monadi, S.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2012, 291 (03) : 831 - 837
  • [2] Advantages of mesh tallying in MCNP5 for soil analysis calculations
    Doron, O.
    Wielopolski, L.
    Biegalski, S.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2008, 276 (01) : 183 - 186
  • [3] Advantages of mesh tallying in MCNP5 for soil analysis calculations
    O. Doron
    L. Wielopolski
    S. Biegalski
    Journal of Radioanalytical and Nuclear Chemistry, 2008, 276 : 183 - 186
  • [4] ADVANTAGES OF MCNPX-BASED LATTICE TALLY OVER MESH TALLY IN HIGH-SPEED MONTE CARLO DOSE RECONSTRUCTION FOR PROTON RADIOTHERAPY
    Zhang, Rui
    Fontenot, Jonas D.
    Mirkovic, Dragan
    Hendricks, John S.
    Newhauser, Wayne D.
    NUCLEAR TECHNOLOGY, 2013, 183 (01) : 101 - 106
  • [5] 3D mesh calculations for covariant density functional theory
    Tanimura, Y.
    Hagino, K.
    Liang, H. Z.
    PROGRESS OF THEORETICAL AND EXPERIMENTAL PHYSICS, 2015, 2015 (07):
  • [6] 3D DOSE CALCULATIONS FOR ELECTRON AND PHOTON BEAMS
    ALTSCHULER, MD
    BLOCH, P
    BUHLE, EL
    AYYALASOMAYAJULA, S
    PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (02): : 391 - 411
  • [7] Monte Carlo-based software for 3D personalized dose calculations in image-guided radiotherapy
    Le Deroff, Coralie
    Berger, Lucie
    Bellec, Julien
    Boissonnat, Guillaume
    Chesneau, Helena
    Chiavassa, Sophie
    Desrousseaux, Julie
    Gempp, Stephanie
    Henry, Olivier
    Jarril, Jimmy
    Lazaro, Delphine
    Lefeuvre, Ronan
    Passal, Vincent
    Solinhac, Fanny
    Lafond, Caroline
    Delpon, Gregory
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2022, 21 : 108 - 114
  • [8] Dose calculation of radiotherapy based on 3D CT data
    Key Laboratory of Process Industry Automation, Shengyang 110004, China
    不详
    Xitong Fangzhen Xuebao, 2006, 11 (3280-3282):
  • [9] 3D implicit mesh-less method for compressible flow calculations
    Sattarzadeh, S.
    Jahangirian, A.
    SCIENTIA IRANICA, 2012, 19 (03) : 503 - 512
  • [10] 3D conformal radiotherapy and intensity-modulated radiotherapy: towards dose optimization
    Almudena Zapatero Laborda
    Revista de Oncología, 2002, 4 (2): : 103 - 108