Advantages of mesh tallying in MCNPX for 3D dose calculations in radiotherapy

被引:0
|
作者
I. Jabbari
M. Shahriari
S. M. R. Aghamiri
S. Monadi
机构
[1] Shahid Beheshti University,Department of Medical Radiation Engineering
[2] Isfahan Milad Hospital,Department of Radiation Oncology
关键词
Monte Carlo; MCNPX; Mesh tally; 3D dose calculation; Treatment planning;
D O I
暂无
中图分类号
学科分类号
摘要
The energy deposition mesh tally option of MCNPX Monte Carlo code is very useful for 3-Dimentional (3D) dose calculations. In this study, the 3D dose calculation was done for CT-based Monte Carlo treatment planning in which the energy deposition mesh tally were superimposed on merged voxel model. The results were compared with those of obtained from the common energy deposition (*F8) tally method for all cells of non-merged voxel model. The results of these two tallies and their respective computational times are compared, and the advantages of the proposed method are discussed. For this purpose, a graphical user interface (GUI) application was developed for reading CT slice data of patient, creating voxelized model of patient, optionally merging adjacent cells with the same material to reduce the total number of cells, reading beam configuration from commercial treatment planning system transferred in DICOM-RT format, and showing the isodose distribution on the CT images. To compare the results of Monte Carlo calculated and TiGRT planning system (LinaTech LLC, USA), treatment head of the Siemens ONCOR Impression accelerator was also simulated and the phase-space data on the scoring plane just above the Y-jaws was created and used. The results for a real prostate intensity-modulated radiation therapy (IMRT) plan showed that the proposed method was fivefold faster while the precision was almost the same.
引用
收藏
页码:831 / 837
页数:6
相关论文
共 50 条
  • [31] A Benchmark for 3D Mesh Segmentation
    Chen, Xiaobai
    Golovinskiy, Aleksey
    Funkhouser, Thomas
    ACM TRANSACTIONS ON GRAPHICS, 2009, 28 (03):
  • [32] 3D adaptive mesh refinement
    Merrouche, A
    Selman, A
    Knopf-Lenoir, C
    COMMUNICATIONS IN NUMERICAL METHODS IN ENGINEERING, 1998, 14 (05): : 397 - 407
  • [33] Multiresolution 3D mesh compression
    Payan, F
    Antonini, M
    2002 INTERNATIONAL CONFERENCE ON IMAGE PROCESSING, VOL II, PROCEEDINGS, 2002, : 245 - 248
  • [34] A 3D coarse-mesh time dependent code for nuclear reactor kinetic calculations
    Montagnini, B
    Raffaelli, P
    Sumini, M
    Zardini, DM
    ANNALS OF NUCLEAR ENERGY, 1996, 23 (06) : 517 - 532
  • [35] Efficient and reliable 3D dose quality assurance for IMRT by combining independent dose calculations with measurements
    Visser, R.
    Wauben, D. J. L.
    de Groot, M.
    Godart, J.
    Langendijk, J. A.
    van't Veld, A. A.
    Korevaar, E. W.
    MEDICAL PHYSICS, 2013, 40 (02)
  • [36] 3D separations: Advantages, feasibility and orthogonality
    Schure, Mark
    Davis, Joe
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2017, 254
  • [37] The Performance and Density Advantages of 3D FPGA
    Nakagawa, Y.
    Osada, K.
    Matsumura, T.
    Koike, H.
    Miyamoto, N.
    Takeda, K.
    PROCESSING MATERIALS OF 3D INTERCONNECTS, DAMASCENE AND ELECTRONICS PACKAGING, 2012, 41 (43): : 125 - 134
  • [38] BETA-MESH - A Dynamic 3D Mesh Modelization
    Caron, Gaetan Marceau
    Hadjaz, Areski
    2011 AMERICAN CONTROL CONFERENCE, 2011,
  • [39] Coding of Dynamic 3D Mesh Model for 3D Video Transmission
    Chiang, Jui-Chiu
    Chen, Chun-Hung
    Lie, Wen-Nung
    ADVANCES IN IMAGE AND VIDEO TECHNOLOGY, PT I, 2011, 7087 : 144 - 152
  • [40] Parallel anisotropic 3D mesh adaptation by mesh modification
    Frédéric Alauzet
    Xiangrong Li
    E. Seegyoung Seol
    Mark S. Shephard
    Engineering with Computers, 2006, 21 : 247 - 258