Advantages of mesh tallying in MCNPX for 3D dose calculations in radiotherapy

被引:0
|
作者
I. Jabbari
M. Shahriari
S. M. R. Aghamiri
S. Monadi
机构
[1] Shahid Beheshti University,Department of Medical Radiation Engineering
[2] Isfahan Milad Hospital,Department of Radiation Oncology
关键词
Monte Carlo; MCNPX; Mesh tally; 3D dose calculation; Treatment planning;
D O I
暂无
中图分类号
学科分类号
摘要
The energy deposition mesh tally option of MCNPX Monte Carlo code is very useful for 3-Dimentional (3D) dose calculations. In this study, the 3D dose calculation was done for CT-based Monte Carlo treatment planning in which the energy deposition mesh tally were superimposed on merged voxel model. The results were compared with those of obtained from the common energy deposition (*F8) tally method for all cells of non-merged voxel model. The results of these two tallies and their respective computational times are compared, and the advantages of the proposed method are discussed. For this purpose, a graphical user interface (GUI) application was developed for reading CT slice data of patient, creating voxelized model of patient, optionally merging adjacent cells with the same material to reduce the total number of cells, reading beam configuration from commercial treatment planning system transferred in DICOM-RT format, and showing the isodose distribution on the CT images. To compare the results of Monte Carlo calculated and TiGRT planning system (LinaTech LLC, USA), treatment head of the Siemens ONCOR Impression accelerator was also simulated and the phase-space data on the scoring plane just above the Y-jaws was created and used. The results for a real prostate intensity-modulated radiation therapy (IMRT) plan showed that the proposed method was fivefold faster while the precision was almost the same.
引用
收藏
页码:831 / 837
页数:6
相关论文
共 50 条
  • [11] Tumor control probability and the utility of 4D vs 3D dose calculations for stereotactic body radiotherapy for lung cancer
    Valdes, Gilmer
    Robinson, Clifford
    Lee, Percy
    Morel, Delphine
    Low, Daniel
    Iwamoto, Keisuke S.
    Lamb, James M.
    MEDICAL DOSIMETRY, 2015, 40 (01) : 64 - 69
  • [12] Development and validation of a 3D dose calculation software for neutron radiotherapy
    Sommer, L.
    Combs, S. E.
    Breitkreutz, H.
    Chemnitz, T.
    Wilkens, J. J.
    RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S820 - S820
  • [13] ADVANTAGES OF IN-OFFICE 3D PRINTING FOR MIDFACE FRACTURE RECONSTRUCTION USING TITANIUM MESH
    Sulea, Daniela
    Sava, Florin
    Gheorghe, Liliana
    Boisteanu, Otilia
    Nicolau, Andrei
    Ciofu, Mihai Liviu
    Costan, Victor-Vlad
    Popescu, Eugenia
    ROMANIAN JOURNAL OF ORAL REHABILITATION, 2021, 13 (04): : 14 - 21
  • [14] Advantages of 3D displays in mobile
    Horikoshi, Tsutomu
    IDW'10: PROCEEDINGS OF THE 17TH INTERNATIONAL DISPLAY WORKSHOPS, VOLS 1-3, 2010, : 2079 - 2082
  • [15] A Mesh-Based Approach for the 3D Analysis of Anatomical Structures of Interest in Radiotherapy
    Mejia-Rodriguez, Aldo R.
    Scalco, Elisa
    Tresoldi, Daniele
    Bianchi, Anna M.
    Arce-Santana, Edgar R.
    Mendez, Martin O.
    Rizzo, Giovanna
    2012 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2012, : 6555 - 6558
  • [16] Reconstructive extremity dosimetry with 3D scanned hand model in MCNPX
    Jiseok Kim
    Chewook Yim
    Siwan Noh
    Han Rim Lee
    Yongkyun Kim
    Journal of Radioanalytical and Nuclear Chemistry, 2018, 316 : 1021 - 1025
  • [17] DOSE DELIVERY VERIFICATION USING 3D DOSE RECONSTRUCTION IN STEREOTACTIC BODY RADIOTHERAPY FOR NSCLC
    van Elmpt, W.
    Petit, S.
    Nijsten, S.
    Lambin, P.
    Dekker, A.
    RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S95 - S96
  • [18] 3D anisotropic mesh adaptation by mesh modification
    Li, XR
    Shephard, MS
    Beall, MW
    COMPUTER METHODS IN APPLIED MECHANICS AND ENGINEERING, 2005, 194 (48-49) : 4915 - 4950
  • [19] A method for incorporating organ motion due to breathing into 3D dose calculations
    Lujan, AE
    Larsen, EW
    Balter, JM
    Ten Haken, RK
    MEDICAL PHYSICS, 1999, 26 (05) : 715 - 720
  • [20] Reconstructive extremity dosimetry with 3D scanned hand model in MCNPX
    Kim, Jiseok
    Yim, Chewook
    Noh, Siwan
    Lee, Han Rim
    Kim, Yongkyun
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2018, 316 (03) : 1021 - 1025