Monte Carlo-based software for 3D personalized dose calculations in image-guided radiotherapy

被引:4
|
作者
Le Deroff, Coralie [1 ]
Berger, Lucie [2 ]
Bellec, Julien [1 ]
Boissonnat, Guillaume [3 ]
Chesneau, Helena [1 ]
Chiavassa, Sophie [4 ]
Desrousseaux, Julie [5 ]
Gempp, Stephanie [5 ]
Henry, Olivier [1 ]
Jarril, Jimmy [2 ]
Lazaro, Delphine [3 ]
Lefeuvre, Ronan [1 ]
Passal, Vincent [4 ]
Solinhac, Fanny [5 ]
Lafond, Caroline [1 ,6 ]
Delpon, Gregory [4 ]
机构
[1] UNICANCER, Ctr Eugene Marquis, Rennes, France
[2] UNICANCER, Ctr Jean Perrin, Clermont Ferrand, France
[3] Univ Paris Saclay, CEA, List, F-91120 Palaiseau, France
[4] UNICANCER, Inst Cancerol Ouest, St Herblain, France
[5] AP HM, Marseille, France
[6] Univ Rennes, INSERM, LTSI UMR 1099, Rennes, France
关键词
IGRT; Monte Carlo dose calculation; Personalized dose; Prostate; Head-and-neck; Breast; GUIDANCE;
D O I
10.1016/j.phro.2022.02.004
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: Image-guided radiotherapy (IGRT) involves frequent in-room imaging sessions contributing to additional patient irradiation. The present work provided patient-specific dosimetric data related to different imaging protocols and anatomical sites.Material and methods: We developed a Monte Carlo based software able to calculate 3D personalized dose distributions for five imaging devices delivering kV-CBCT (Elekta and Varian linacs), MV-CT (Tomotherapy machines) and 2D-kV stereoscopic images from BrainLab and Accuray. Our study reported the dose distributions calculated for pelvis, head and neck and breast cases based on dose volume histograms for several organs at risk. Results: 2D-kV imaging provided the minimum dose with less than 1 mGy per image pair. For a single kV-CBCT and MV-CT, median dose to organs were respectively around 30 mGy and 15 mGy for the pelvis, around 7 mGy and 10 mGy for the head and neck and around 5 mGy and 15 mGy for the breast. While MV-CT dose varied sparsely with tissues, dose from kV imaging was around 1.7 times higher in bones than in soft tissue. Daily kVCBCT along 40 sessions of prostate radiotherapy delivered up to 3.5 Gy to the femoral heads. The dose level for head and neck and breast appeared to be lower than 0.4 Gy for every organ in case of a daily imaging session. Conclusions: This study showed the dosimetric impact of IGRT procedures. Acquisition parameters should therefore be chosen wisely depending on the clinical purposes and tailored to morphology. Indeed, imaging dose could be reduced up to a factor 10 with optimized protocols.
引用
收藏
页码:108 / 114
页数:7
相关论文
共 50 条
  • [1] Uncertainties in Monte Carlo-based absorbed dose calculations for an experimental benchmark
    Renner, F.
    Wulff, J.
    Kapsch, R-P
    Zink, K.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (19): : 7637 - 7653
  • [2] An anatomically realistic lung model for Monte Carlo-based dose calculations
    Liang, Liang
    Larsen, Edward W.
    Chetty, Indrin J.
    [J]. MEDICAL PHYSICS, 2007, 34 (03) : 1013 - 1025
  • [3] Comparison of two Monte Carlo-based codes for small-field dose calculations in external beam radiotherapy
    Partanen, Mari
    Ojala, Jarkko
    Niemela, Jarkko
    Bjorkqvist, Mikko
    Keyrilainen, Jani
    Kapanen, Mika
    [J]. ACTA ONCOLOGICA, 2017, 56 (06) : 891 - 893
  • [4] The Effect of Monte Carlo-Based Dose Calculations On Tumor Control Probability Modeling
    Huang, E.
    Lindsay, P.
    Hope, A.
    El Naqa, I.
    Bradley, J.
    Deasy, J.
    [J]. MEDICAL PHYSICS, 2009, 36 (06)
  • [5] Organ and effective dose from kV stereoscopic imaging as part of image-guided radiotherapy: a Monte Carlo study
    Platten, D. J.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S839 - S840
  • [6] 3D Surface Image-Guided
    Tang, X.
    [J]. MEDICAL PHYSICS, 2016, 43 (06) : 3816 - 3817
  • [7] Construction of a Surface-Based 3D Human Model and Monte Carlo Dose Calculations
    Kim, C.
    Jeong, J.
    Yeom, Y.
    Cho, S.
    Cho, K.
    [J]. MEDICAL PHYSICS, 2008, 35 (06)
  • [8] PATIENT DOSE IN IMAGE GUIDED RADIOTHERAPY: MONTE CARLO STUDY OF THE CBCT DOSE CONTRIBUTION
    Leotta, Salvatore
    Amato, Ernesto
    Settineri, Nicola
    Basile, Emilia
    Italiano, Antonio
    Auditore, Lucrezia
    Santacaterina, Anna
    Pergolizzi, Stefano
    [J]. ATTI ACCADEMIA PELORITANA DEI PERICOLANTI-CLASSE DI SCIENZE FISICHE MATEMATICHE E NATURALI, 2018, 96 (01):
  • [9] Monte Carlo based 3D Absorbed Dose Distributions for Organs at Risk in Molecular Radiotherapy
    Marcatili, S.
    Spezi, E.
    Daniels, S.
    Lewis, G.
    Edwards, P.
    Mason, M.
    Pettinato, C.
    Fanti, S.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2012, 39 : S350 - S350
  • [10] Low cost multifunctional 3D printed image quality and dose verification phantom for an image-guided radiotherapy system
    Wu, Jian-Kuen
    Yu, Min-Chin
    Chen, Shih-Han
    Liao, Shu-Hsien
    Wang, Yu-Jen
    [J]. PLOS ONE, 2022, 17 (04):