Low cost multifunctional 3D printed image quality and dose verification phantom for an image-guided radiotherapy system

被引:3
|
作者
Wu, Jian-Kuen [1 ]
Yu, Min-Chin [2 ]
Chen, Shih-Han [3 ]
Liao, Shu-Hsien [4 ]
Wang, Yu-Jen [5 ,6 ]
机构
[1] Natl Taiwan Univ Hosp, Dept Oncol, Div Radiat Oncol, Taipei, Taiwan
[2] Taipei Med Univ Hosp, Dept Radiat Oncol, Taipei, Taiwan
[3] Natl Taiwan Univ, Dept Med Imaging, Canc Ctr, Taipei, Taiwan
[4] Natl Taiwan Normal Univ, Inst Electroopt Sci & Technol, Taipei, Taiwan
[5] Fu Jen Catholic Univ Hosp, Dept Radiat Oncol, New Taipei, Taiwan
[6] Fu Jen Catholic Univ, Coll Med, Sch Med, New Taipei, Taiwan
来源
PLOS ONE | 2022年 / 17卷 / 04期
关键词
ASSURANCE; CT; DOSIMETRY; MRI;
D O I
10.1371/journal.pone.0266604
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
PurposeImage-guided radiation therapy (IGRT) is used to precisely deliver radiation to a tumour to reduce the possible damage to the surrounding normal tissues. Clinics use various quality assurance (QA) equipment to ensure that the performance of the IGRT system meets the international standards set for the system. The objective of this study was to develop a low-cost and multipurpose module for evaluating image quality and dose. MethodsA multipurpose phantom was designed to meet the clinical requirements of high accuracy, easy setup, and calibration. The outer shell of the phantom was fabricated using acrylic. Three dimensional (3D) printing technology was used to fabricate inner slabs with the characteristics of high spatial resolution, low-contrast detectability, a 3D grid, and liquid-filled uniformity. All materials were compatible with magnetic resonance (MR). Computed tomography (CT) simulator and linear accelerator (LINAC) modules were developed and validated. ResultsThe uniformity slab filled with water is ideal for the assessment of Hounsfield units, whereas that filled with wax is suitable for consistency checks. The high-spatial-resolution slab enables measurements with a resolution up to 5 lp/cm. The low-contrast detectability slab contains rods of 5 different sizes that can be clearly visualised. These components meet the American College of Radiology (ACR) standards for QA of CT simulators and LINACs. ConclusionsThe multifunctional phantom module meets the ACR recommended QA guidelines and is suitable for both LINACs and CT-sim. Further measurements in an MR simulator and an MR linear accelerator (MR-LINAC) will be arranged in the future.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Dose verification for image-guided radiotherapy
    Kapatoes, J
    Ruchala, K
    Olivera, G
    Forrest, L
    Turek, M
    Mackie, T
    Welsh, J
    Jaradat, H
    Balog, J
    Lu, W
    Jeraj, R
    Reckwerdt, P
    [J]. MEDICAL PHYSICS, 2003, 30 (06) : 1418 - 1419
  • [2] 3D Spatial Compounding Using the Clarity System Improves Ultrasound Image Quality in Gynecological Image-Guided Radiotherapy
    Mason, S.
    O'Shea, T.
    White, I.
    McNair, H.
    Blackledge, M.
    Laldondrelle, S.
    Bamber, J.
    Harris, E.
    [J]. MEDICAL PHYSICS, 2017, 44 (06) : 3069 - 3069
  • [3] MULTIPLE 3D MARKER LOCALIZATION AND TRACKING SYSTEM IN IMAGE-GUIDED RADIOTHERAPY
    Mao, Songan
    Wu, Huanmei
    Lu, Minghui
    Cheng, Chee-Wai
    [J]. INTERNATIONAL JOURNAL OF ROBOTICS & AUTOMATION, 2017, 32 (05): : 517 - 523
  • [4] Treatment dose verification for image-guided stereotactic radiotherapy of lung cancer
    Wang, L
    Feigenberg, S
    Paskalev, K
    Konski, A
    Xiong, W
    Ma, C
    [J]. MEDICAL PHYSICS, 2005, 32 (06) : 1941 - 1941
  • [5] Online dose delivery verification in small animal image-guided radiotherapy
    Anvari, Akbar
    Modiri, Arezoo
    Pandita, Ravina
    Mahmood, Javed
    Sawant, Amit
    [J]. MEDICAL PHYSICS, 2020, 47 (04) : 1871 - 1879
  • [6] Low dose cone beam CT for paediatric image-guided radiotherapy: Image quality and practical recommendations
    Bryce-Atkinson, Abigail
    De Jong, Rianne
    Marchant, Tom
    Whitfield, Gillian
    Aznar, Marianne C.
    Bel, Arjan
    van Herk, Marcel
    [J]. RADIOTHERAPY AND ONCOLOGY, 2021, 163 : 68 - 75
  • [7] 3D Surface Image-Guided
    Tang, X.
    [J]. MEDICAL PHYSICS, 2016, 43 (06) : 3816 - 3817
  • [8] From image-guided radiotherapy to dose-guided radiotherapy
    Cazoulat, G.
    Lesaunier, M.
    Simon, A.
    Haigron, P.
    Acosta, O.
    Louvel, G.
    Lafond, C.
    Chajon, E.
    Leseur, J.
    de Crevoisier, R.
    [J]. CANCER RADIOTHERAPIE, 2011, 15 (08): : 691 - 698
  • [9] Monte Carlo-based software for 3D personalized dose calculations in image-guided radiotherapy
    Le Deroff, Coralie
    Berger, Lucie
    Bellec, Julien
    Boissonnat, Guillaume
    Chesneau, Helena
    Chiavassa, Sophie
    Desrousseaux, Julie
    Gempp, Stephanie
    Henry, Olivier
    Jarril, Jimmy
    Lazaro, Delphine
    Lefeuvre, Ronan
    Passal, Vincent
    Solinhac, Fanny
    Lafond, Caroline
    Delpon, Gregory
    [J]. PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2022, 21 : 108 - 114
  • [10] Automation of image registration and verification for image-guided stereotactic body radiotherapy
    Wang, C
    Shiu, A
    Lii, M
    Chang, E
    [J]. MEDICAL PHYSICS, 2005, 32 (06) : 1943 - 1943