Low cost multifunctional 3D printed image quality and dose verification phantom for an image-guided radiotherapy system

被引:3
|
作者
Wu, Jian-Kuen [1 ]
Yu, Min-Chin [2 ]
Chen, Shih-Han [3 ]
Liao, Shu-Hsien [4 ]
Wang, Yu-Jen [5 ,6 ]
机构
[1] Natl Taiwan Univ Hosp, Dept Oncol, Div Radiat Oncol, Taipei, Taiwan
[2] Taipei Med Univ Hosp, Dept Radiat Oncol, Taipei, Taiwan
[3] Natl Taiwan Univ, Dept Med Imaging, Canc Ctr, Taipei, Taiwan
[4] Natl Taiwan Normal Univ, Inst Electroopt Sci & Technol, Taipei, Taiwan
[5] Fu Jen Catholic Univ Hosp, Dept Radiat Oncol, New Taipei, Taiwan
[6] Fu Jen Catholic Univ, Coll Med, Sch Med, New Taipei, Taiwan
来源
PLOS ONE | 2022年 / 17卷 / 04期
关键词
ASSURANCE; CT; DOSIMETRY; MRI;
D O I
10.1371/journal.pone.0266604
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
PurposeImage-guided radiation therapy (IGRT) is used to precisely deliver radiation to a tumour to reduce the possible damage to the surrounding normal tissues. Clinics use various quality assurance (QA) equipment to ensure that the performance of the IGRT system meets the international standards set for the system. The objective of this study was to develop a low-cost and multipurpose module for evaluating image quality and dose. MethodsA multipurpose phantom was designed to meet the clinical requirements of high accuracy, easy setup, and calibration. The outer shell of the phantom was fabricated using acrylic. Three dimensional (3D) printing technology was used to fabricate inner slabs with the characteristics of high spatial resolution, low-contrast detectability, a 3D grid, and liquid-filled uniformity. All materials were compatible with magnetic resonance (MR). Computed tomography (CT) simulator and linear accelerator (LINAC) modules were developed and validated. ResultsThe uniformity slab filled with water is ideal for the assessment of Hounsfield units, whereas that filled with wax is suitable for consistency checks. The high-spatial-resolution slab enables measurements with a resolution up to 5 lp/cm. The low-contrast detectability slab contains rods of 5 different sizes that can be clearly visualised. These components meet the American College of Radiology (ACR) standards for QA of CT simulators and LINACs. ConclusionsThe multifunctional phantom module meets the ACR recommended QA guidelines and is suitable for both LINACs and CT-sim. Further measurements in an MR simulator and an MR linear accelerator (MR-LINAC) will be arranged in the future.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] MULTI-SYSTEM VERIFICATION OF REGISTRATIONS FOR IMAGE-GUIDED RADIOTHERAPY IN CLINICAL TRIALS
    Cui, Yunfeng
    Galvin, James M.
    Straube, William L.
    Bosch, Walter R.
    Purdy, James A.
    Li, X. Allen
    Xiao, Ying
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 81 (01): : 305 - 312
  • [22] 3D Image-Guided Robotic System for Bone Fracture Reduction
    Lee, Seongpung
    Joung, Sanghyun
    Ha, Ho-Gun
    Lee, Jin-Han
    Park, Kyeong-Hyeon
    Kim, Shinyeol
    Nam, Kwonsun
    Lee, Jongsuk
    Lee, Hyun-Joo
    Oh, Chang-Wug
    Park, Ilhyung
    Hong, Jaesung
    [J]. IEEE ROBOTICS AND AUTOMATION LETTERS, 2022, 7 (02): : 4353 - 4360
  • [23] Fabrication and characterization of a multimodal 3D printed mouse phantom for ionoacoustic quality assurance in image-guided pre-clinical proton radiation research
    Lascaud, Julie
    Dash, Pratik
    Schnuerle, Katrin
    Bortfeldt, Jonathan
    Niepel, Katharina
    Maas, Jessica
    Wuerl, Matthias
    Vidal, Marie
    Herault, Joel
    Landry, Guillaume
    Savoia, Alessandro Stuart
    Lauber, Kirsten
    Parodi, Katia
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2022, 67 (20):
  • [24] Commissioning an image-guided localization system for radiotherapy
    Phillips, MH
    Singer, K
    Miller, E
    Stelzer, K
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 48 (01): : 267 - 276
  • [25] Development of a 3D printed anthropomorphic lung phantom for image quality assessment in CT
    Hernandez-Giron, Irene
    den Harder, Johan Michiel
    Streekstra, Geert J.
    Geleijns, Jacob
    Veldkamp, Wouter J. H.
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 57 : 47 - 57
  • [26] 3D-printed Magnetic Resonance (MR)-based gynecological phantom for image-guided brachytherapy training
    Kut, Carmen
    Kao, Tracy
    Morcos, Marc
    Kim, Younsu
    Boctor, Emad
    Viswanathan, Akila N.
    [J]. BRACHYTHERAPY, 2022, 21 (06) : 799 - 805
  • [27] A device for realtime 3D image-guided IMRT
    Dempsey, JF
    Benoit, D
    Fitzsimmons, JR
    Haghighat, A
    Li, JG
    Low, DA
    Mutic, S
    Palta, JR
    Romeijn, HE
    Sjoden, GE
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 63 (02): : S202 - S202
  • [28] 3D Ultrasound Imaging in Image-Guided Intervention
    Fenster, Aaron
    Bax, Jeff
    Neshat, Hamid
    Cool, Derek
    Kakani, Nirmal
    Romagnoli, Cesare
    [J]. 2014 36TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2014, : 6151 - 6154
  • [29] Verification of optimal fiducial marker configurations in image-guided radiotherapy
    Liu, H
    Ruo, R
    Schell, MC
    Okunieff, P
    O'Dell, W
    Yu, Y
    [J]. MEDICAL PHYSICS, 2002, 29 (06) : 1241 - 1241
  • [30] Augmented reality: 3D image-guided surgery
    Archie Hughes-Hallett
    Philip Pratt
    James Dilley
    Justin Vale
    Ara Darzi
    Erik Mayer
    [J]. Cancer Imaging, 15 (Suppl 1)