Online dose delivery verification in small animal image-guided radiotherapy

被引:7
|
作者
Anvari, Akbar [1 ,2 ]
Modiri, Arezoo [1 ]
Pandita, Ravina [1 ]
Mahmood, Javed [1 ]
Sawant, Amit [1 ]
机构
[1] Univ Maryland, Sch Med, Dept Radiat Oncol, Baltimore, MD 21201 USA
[2] Univ Penn, Dept Radiat Oncol, Perelman Ctr Adv Med, Philadelphia, PA 19104 USA
关键词
dose verification; EPID; small animal image-guided radiotherapy; treatment plan; DOSIMETRY; TECHNOLOGY;
D O I
10.1002/mp.14070
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To accomplish novel radiation treatment techniques in preclinical radiation research, small animal image-guided radiotherapy systems have been increasingly integrated into preclinical radiation research over the last decade. Although such systems have sophisticated tools (such as cone-beam computed tomography-based image guidance, robotic couch, treatment planning system (TPS), and electronic portal imaging devices [EPIDs]). To our knowledge, no established technique can perform independent and online verification of the delivered dose during radiotherapy. In this study, we implement an online EPID dosimetry for each administered SA-IGRT fraction in a rat orthotopic model of prostate cancer. Methods To verify the accuracy of delivered dose to rat, we compared the two-dimensional (2D) calculated dose distribution by TPS as the planned dose, with online dose distribution estimated using an EPID as the delivered dose. Since image acquisition software was not capable of acquiring integrated images over a long period of time, we used the EPID to estimate dose rate rather than dose. The central axis (CAX) dose rate values at the beam's exit surface were compared. In addition, 2D dose distributions were also compared under different gamma criteria. To verify the accuracy of our EPID dosimetry technique, we measured transit and exit doses with film during animal treatment. In this study, 20-mm cone was used to collimate beam. We previously observed that the EPID response was independent of collimator size for collimator size >= 15-mm, we did not apply for additional correction factor. Results Comparison of exit CAX dose rate values of TPS-calculated and EPID-estimated showed that the average difference was 3.1%, with a maximum of 9.3%. Results of gamma analysis for 2D comparison indicated an average of 90% passing rate with global gamma criterion of 2 mm/5%. We observed that TPS could not calculate dose accurately in peripheral regions in which the penumbra effect was dominant. Dose rate values estimated by EPID were within 2.1% agreement with film at both the imager plane and the beam's exit surface for 4 randomly selected animals for which film measurement verification was performed. Conclusions The small animal radiation research platform (SARRP) system's built-in EPID was utilized to estimate dose delivered to rats at kilovoltage energy x-rays. The results of this study suggest that the EPID is an invaluable tool for verifying delivered dose to small animal to help validate conclusions made from preclinical radiation research.
引用
收藏
页码:1871 / 1879
页数:9
相关论文
共 50 条
  • [1] Dose verification for image-guided radiotherapy
    Kapatoes, J
    Ruchala, K
    Olivera, G
    Forrest, L
    Turek, M
    Mackie, T
    Welsh, J
    Jaradat, H
    Balog, J
    Lu, W
    Jeraj, R
    Reckwerdt, P
    [J]. MEDICAL PHYSICS, 2003, 30 (06) : 1418 - 1419
  • [2] Dose painting by dynamic irradiation delivery on an image-guided small animal radiotherapy platform
    Van Hoof, Stefan J.
    Verde, Joana B.
    Verhaegen, Frank
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2019, 92 (1095):
  • [3] Small animal image-guided radiotherapy
    Verhaegen, Frank
    Vaz, Pedro
    Prise, Kevin M.
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2019, 92 (1095):
  • [4] Small animal image-guided radiotherapy
    Prise, Kevin M.
    Verhaegen, Frank
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2017, 90 (1069):
  • [5] IMAGE GUIDED COMPLEX DOSE DELIVERY FOR SMALL ANIMAL RADIOTHERAPY
    Matinfar, Mohammad
    Iyer, Santosh
    Ford, Eric
    Wong, John
    Kazanzides, Peter
    [J]. 2009 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, VOLS 1 AND 2, 2009, : 1243 - +
  • [6] Dosimetric verification and commissioning for a small animal image-guided irradiator
    Wang, Yi-Fang
    Lin, Shih-Chi
    Na, Yong Hum
    Black, Paul J.
    Wuu, Cheng-Shie
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (14):
  • [7] Dosimetric Verification and Commissioning for an Image-Guided Small Animal Irradiator
    Wang, Y. F.
    Lin, S. C.
    Na, Y. H.
    Black, P. J.
    Wuu, C. S.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2017, 99 (02): : E624 - E624
  • [8] Implications of respiratory motion for small animal image-guided radiotherapy
    Hill, Mark A.
    Vojnovic, Borivoj
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2017, 90 (1069):
  • [9] Treatment dose verification for image-guided stereotactic radiotherapy of lung cancer
    Wang, L
    Feigenberg, S
    Paskalev, K
    Konski, A
    Xiong, W
    Ma, C
    [J]. MEDICAL PHYSICS, 2005, 32 (06) : 1941 - 1941
  • [10] On the use of an analytic source model for dose calculations in precision image-guided small animal radiotherapy
    Granton, Patrick V.
    Verhaegen, Frank
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (10): : 3377 - 3395