Online dose delivery verification in small animal image-guided radiotherapy

被引:7
|
作者
Anvari, Akbar [1 ,2 ]
Modiri, Arezoo [1 ]
Pandita, Ravina [1 ]
Mahmood, Javed [1 ]
Sawant, Amit [1 ]
机构
[1] Univ Maryland, Sch Med, Dept Radiat Oncol, Baltimore, MD 21201 USA
[2] Univ Penn, Dept Radiat Oncol, Perelman Ctr Adv Med, Philadelphia, PA 19104 USA
关键词
dose verification; EPID; small animal image-guided radiotherapy; treatment plan; DOSIMETRY; TECHNOLOGY;
D O I
10.1002/mp.14070
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To accomplish novel radiation treatment techniques in preclinical radiation research, small animal image-guided radiotherapy systems have been increasingly integrated into preclinical radiation research over the last decade. Although such systems have sophisticated tools (such as cone-beam computed tomography-based image guidance, robotic couch, treatment planning system (TPS), and electronic portal imaging devices [EPIDs]). To our knowledge, no established technique can perform independent and online verification of the delivered dose during radiotherapy. In this study, we implement an online EPID dosimetry for each administered SA-IGRT fraction in a rat orthotopic model of prostate cancer. Methods To verify the accuracy of delivered dose to rat, we compared the two-dimensional (2D) calculated dose distribution by TPS as the planned dose, with online dose distribution estimated using an EPID as the delivered dose. Since image acquisition software was not capable of acquiring integrated images over a long period of time, we used the EPID to estimate dose rate rather than dose. The central axis (CAX) dose rate values at the beam's exit surface were compared. In addition, 2D dose distributions were also compared under different gamma criteria. To verify the accuracy of our EPID dosimetry technique, we measured transit and exit doses with film during animal treatment. In this study, 20-mm cone was used to collimate beam. We previously observed that the EPID response was independent of collimator size for collimator size >= 15-mm, we did not apply for additional correction factor. Results Comparison of exit CAX dose rate values of TPS-calculated and EPID-estimated showed that the average difference was 3.1%, with a maximum of 9.3%. Results of gamma analysis for 2D comparison indicated an average of 90% passing rate with global gamma criterion of 2 mm/5%. We observed that TPS could not calculate dose accurately in peripheral regions in which the penumbra effect was dominant. Dose rate values estimated by EPID were within 2.1% agreement with film at both the imager plane and the beam's exit surface for 4 randomly selected animals for which film measurement verification was performed. Conclusions The small animal radiation research platform (SARRP) system's built-in EPID was utilized to estimate dose delivered to rats at kilovoltage energy x-rays. The results of this study suggest that the EPID is an invaluable tool for verifying delivered dose to small animal to help validate conclusions made from preclinical radiation research.
引用
收藏
页码:1871 / 1879
页数:9
相关论文
共 50 条
  • [21] Characterization of Inorganic Scintillator Detectors for Dosimetry in Image-Guided Small Animal Radiotherapy Platforms
    Silvestre Patallo, Ileana
    Subiel, Anna
    Carter, Rebecca
    Flynn, Samuel
    Schettino, Giuseppe
    Nisbet, Andrew
    [J]. CANCERS, 2023, 15 (03)
  • [22] Verification of optimal fiducial marker configurations in image-guided radiotherapy
    Liu, H
    Ruo, R
    Schell, MC
    Okunieff, P
    O'Dell, W
    Yu, Y
    [J]. MEDICAL PHYSICS, 2002, 29 (06) : 1241 - 1241
  • [23] Distortion verification of helical computed tomography for image-guided radiotherapy
    Harada, Takayuki
    Takemura, Akihiro
    [J]. JOURNAL OF RADIOTHERAPY IN PRACTICE, 2023, 22
  • [24] Image-guided radiotherapy
    de Crevoisier, R.
    Isambert, A.
    Lisbona, A.
    Bodez, V.
    Marguet, M.
    Lafay, F.
    Remonnay, R.
    Lagrange, J. -L.
    [J]. CANCER RADIOTHERAPIE, 2007, 11 (6-7): : 296 - 304
  • [25] Image-guided radiotherapy
    de Crevoisier, R.
    Lafond, C.
    Mervoyer, A.
    Hulot, C.
    Jaksic, N.
    Bessieres, I
    Delpon, G.
    [J]. CANCER RADIOTHERAPIE, 2022, 26 (1-2): : 34 - 49
  • [26] Development of an image-guided robot for small animal research
    Kazanzides, Peter
    Chang, Jenghwa
    Iordachita, Iulian
    Li, Jack
    Ling, C. Clifton
    Fichtinger, Gabor
    [J]. COMPUTER AIDED SURGERY, 2007, 12 (06) : 357 - 365
  • [27] Image-guided IMRT dose verification with a plastic photosensitive dosimeter
    Pawlicki, T
    Luxton, G
    Maxim, P
    Mistry, V
    Bourland, P
    Boyer, A
    [J]. MEDICAL PHYSICS, 2005, 32 (06) : 1995 - 1996
  • [28] Evaluation of a Novel Liquid Fiducial Marker, BioXmark®, for Small Animal Image-Guided Radiotherapy Applications
    Brown, Kathryn H.
    Ghita, Mihaela
    Schettino, Giuseppe
    Prise, Kevin M.
    Butterworth, Karl T.
    [J]. CANCERS, 2020, 12 (05)
  • [29] Stereotactic body radiotherapy with image-guided delivery for liver metastasis
    Ricchetti, F.
    Fersino, S.
    Mazzola, R.
    Fiorentino, A.
    Levra, N. Giaj
    Aiello, D.
    Gregucci, F.
    Tebano, U.
    Sicignano, G.
    Naccarato, S.
    Ruggieri, R.
    Alongi, F.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S770 - S770
  • [30] Imaging Dose and Cancer Risk in Image-Guided Radiotherapy of Cancers
    Zhou, L.
    Bai, S.
    Zhang, Y.
    Ming, X.
    Zhang, Y.
    Deng, J.
    [J]. MEDICAL PHYSICS, 2014, 41 (06) : 123 - 123