PATIENT DOSE IN IMAGE GUIDED RADIOTHERAPY: MONTE CARLO STUDY OF THE CBCT DOSE CONTRIBUTION

被引:1
|
作者
Leotta, Salvatore [1 ]
Amato, Ernesto [2 ,3 ]
Settineri, Nicola [4 ]
Basile, Emilia [4 ]
Italiano, Antonio [3 ]
Auditore, Lucrezia [3 ,5 ]
Santacaterina, Anna [4 ]
Pergolizzi, Stefano [2 ,5 ]
机构
[1] Radiosurg Ctr, Agropoli, Italy
[2] Univ Messina, Dipartimento Sci Biomed Odontoiatr & Immagini Mor, Messina, Italy
[3] Ist Nazl Fis Nucl, Sez Catania, Catania, Italy
[4] Azienda Osped Papardo, Messina, Italy
[5] Azienda Osped Univ Policlin G Martino, Messina, Italy
关键词
D O I
10.1478/AAPP.961A3
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Image Guided RadioTherapy (IGRT) is a technique whose diffusion is growing thanks to the well-recognized gain in accuracy of dose delivery. However, multiple Cone Beam Computed Tomography (CBCT) scans add dose to patients, and its contribution has to be assessed and minimized. Aim of our work was to evaluate, through Monte Carlo simulations, organ doses in IGRT due to CBCT and therapeutic MV irradiation in head-neck, thorax and pelvis districts. We developed a Monte Carlo simulation in GAMOS (Geant4-based Architecture for Medicine-Oriented Simulations), reproducing an Elekta Synergy medical linac operating at 6 and 10 MV photon energy, and we set up a scalable anthropomorphic model. After a validation by comparison with the experimental quality indexes, we evaluated the average doses to all organs and tissues belonging to the model for the three cases of irradiated district. Scattered radiation in therapy is larger than that diffused by CBCT by one to two orders of magnitude.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Reduce Patient Dose and Improve Image Quality in CBCT for Image Guided Radiotherapy
    Jin, J.
    Ren, L.
    Kim, J.
    Movsas, B.
    Chetty, I.
    MEDICAL PHYSICS, 2010, 37 (06) : 3384 - +
  • [2] Monte Carlo based patient dose reconstruction from portal images for image guided adaptive radiotherapy
    Flampouri, S
    Aljarrah, K
    Jiang, SB
    MEDICAL PHYSICS, 2004, 31 (06) : 1821 - 1822
  • [3] Study of Reduction Technique for the Secondary Dose Due to CBCT in Image Guided Radiotherapy
    Sung, J.
    Kim, D.
    Chung, W.
    Kim, D.
    Yoon, M.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [4] Dose Verification and Monte Carlo Modeling of an Image-Guided Small Animal Radiotherapy Irradiator
    Dominici, J. D.
    Gutu, T.
    Wang, C.
    MEDICAL PHYSICS, 2024, 51 (10) : 7706 - 7706
  • [5] Organ and effective dose from kV stereoscopic imaging as part of image-guided radiotherapy: a Monte Carlo study
    Platten, D. J.
    RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S839 - S840
  • [6] Study of Dose Calculation Using Monte Carlo Method in Radiotherapy
    Gao, C.
    Chi, Z.
    Liu, D.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [7] Patient-specific dose assessment using CBCT images and Monte Carlo calculations
    Aghaz, A.
    Kardan, M. R.
    Deevband, M. R.
    Bahadorzadeh, B.
    Kasesaz, Y.
    Ghadiri, H.
    JOURNAL OF INSTRUMENTATION, 2021, 16 (10)
  • [8] Monte Carlo simulation of dose distribution of radiotherapy
    Liu, YM
    Xue, DY
    Xu, XH
    Chen, Z
    System Simulation and Scientific Computing, Vols 1 and 2, Proceedings, 2005, : 422 - 426
  • [9] ORANGE: a Monte Carlo dose engine for radiotherapy
    van der Zee, W
    Hogenbirk, A
    van der Marck, SC
    PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (04): : 625 - 641
  • [10] Patient-specific skin dose evaluation in breast cancer radiotherapy: A Monte Carlo study
    Atarod, Maryam
    Shami, Nahid
    Pourmoghaddas, Amir
    Saeb, Mohsen
    RADIATION PHYSICS AND CHEMISTRY, 2025, 231