Feasibility and safety of non-contrast optical coherence tomography imaging using hydroxyethyl starch in coronary arteries

被引:0
|
作者
Dong Oh Kang
Hyeong Soo Nam
Sunwon Kim
Hongki Yoo
Jin Won Kim
机构
[1] Korea University Guro Hospital,Multimodal Imaging and Theranostic Laboratory, Cardiovascular Center
[2] Korea University Guro Hospital,Cardiovascular Center
[3] Korea Advanced Institute of Science and Technology,Department of Mechanical Engineering
[4] Korea University Ansan Hospital,Cardiovascular Center
关键词
D O I
暂无
中图分类号
学科分类号
摘要
Intracoronary optical coherence tomography (OCT) requires injection of flushing media for image acquisition. Alternative flushing media needs to be investigated to reduce the risk of contrast-induced renal dysfunction. We investigated the feasibility and safety of pentastarch (hydroxyethyl starch) for clinical OCT imaging. We prospectively enrolled 43 patients with 70 coronary lesions (46-stented; 24-native). Total 81 OCT pullback pairs were obtained by manual injection of iodine contrast, followed by pentastarch. Each pullback was assessed frame-by-frame using an automated customized lumen contour/stent strut segmentation algorithm. Paired images were compared for the clear image segments (CIS), blood-flushing capability, and quantitative morphometric measurements. Overall image quality, as assessed by the proportion of CIS, was comparable between the contrast- and pentastarch-flushed images (97.1% vs. 96.5%; p = 0.160). The pixel-based blood-flushing capability was similar between the groups (0.951 [0.947–0.953] vs. 0.950 [0.948–0.952], p = 0.125). Quantitative two- and three-dimensional morphometric measurements of the paired images correlated well (p < 0.001) with excellent inter-measurement variability. All patients safely underwent OCT imaging using pentastarch without resulting in clinically relevant complications or renal deterioration. Non-contrast OCT imaging using pentastarch is clinically safe and technically feasible with excellent image quality and could be a promising alternative strategy for patients at high risk of renal impairment.
引用
下载
收藏
相关论文
共 50 条
  • [11] Optical Coherence Tomography of Coronary Arteries
    Roland, Robert
    Veselka, Josef
    INTERNATIONAL JOURNAL OF ANGIOLOGY, 2021, 30 (01) : 29 - 39
  • [12] Optical coherence tomography of coronary arteries - a novel intravascular imaging modality
    Mrevlje, B.
    Legutko, J.
    Jakala, J.
    Noc, M.
    Dudek, D.
    Birkemeyer, R.
    Aboukoura, M.
    Nienaber, C.
    DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 2014, 139 (39) : 1941 - 1946
  • [13] Imaging of coronary artery plaques using contrast-enhanced optical coherence tomography
    Foin, Nicolas
    Mari, Jean Martial
    Davies, Justin E.
    Di Mario, Carlo
    Girard, Michael J. A.
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2013, 14 (01) : 85 - 85
  • [14] Feasibility and safety of non-contrast percutaneous coronary intervention in patients with complicated acute coronary syndrome
    Higuchi, S.
    Kabeya, Y.
    Nishina, Y.
    Miura, Y.
    Yoshino, H.
    EUROPEAN HEART JOURNAL, 2020, 41 : 1751 - 1751
  • [15] Contrast-free optical coherence tomography:Systematic evaluation of non-contrast media for intravascular assessment
    Simard, Trevor
    Motazedian, Pouya
    Majeed, Kamran
    Sarathy, Kiran
    Jung, Richard G.
    Feder, Joshua
    Ramirez, F. Daniel
    Di Santo, Pietro
    Marbach, Jeffrey
    Dhaliwal, Shan
    Short, Spencer
    Labinaz, Alisha
    Schultz, Carl
    Russo, Juan J.
    So, Derek
    Chong, Aun-Yeong
    Le May, Michel
    Hibbert, Benjamin
    PLOS ONE, 2020, 15 (08):
  • [16] Feasibility and Safety of Very-Low Contrast Combined Ringer's Solution in Optical Coherence Tomography Imaging
    Chen, Tao
    Yu, Huai
    Ma, Lijia
    Fang, Chao
    Jia, Haibo
    Liu, Huimin
    Xu, Maoen
    Zhang, Donghui
    Yang, Guang
    Zhang, Shuangyin
    Han, Jincheng
    Wei, Guo
    Liu, Yanchao
    Hou, Jingbo
    Yu, Bo
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2022, 9
  • [17] Optical coherence tomography of coronary arteries in vitro using a new catheter
    Shishkov, M
    Bouma, BE
    Jang, IK
    Kang, DH
    Aretz, HT
    Houser, SL
    Brady, TJ
    Schlendorf, K
    Tearney, GJ
    BIOMEDICAL TOPICAL MEETINGS, TECHNICAL DIGEST, 2000, 38 : 35 - 37
  • [18] In the play of light - Visualization of coronary arteries using optical coherence tomography
    Konyi, Attila
    Komocsi, Andras
    Pinter, Tuende
    Horvath, Ivan
    INTERVENTIONAL MEDICINE AND APPLIED SCIENCE, 2011, 3 (01): : 39 - 44
  • [19] DETECTION OF LIPID IN CORONARY ARTERIES USING PHOTOTHERMAL OPTICAL COHERENCE TOMOGRAPHY
    Katta, Nitesh
    Cabe, Andrew
    Hoyt, Taylor
    McElroy, Austin B.
    Feldman, Marc
    Milner, Thomas
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2019, 73 (09) : 1421 - 1421
  • [20] Zero contrast optical coherence tomography-guided percutaneous coronary intervention for in-stent restenosis of the saphenous vein graft using a non-contrast flush medium
    Vasu, Nandhakumar
    Subban, Vijayakumar
    Mullasari, S. Ajit
    INDIAN HEART JOURNAL, 2018, 70 : S492 - S495