Contrast-free optical coherence tomography:Systematic evaluation of non-contrast media for intravascular assessment

被引:6
|
作者
Simard, Trevor [1 ,2 ]
Motazedian, Pouya [1 ,3 ]
Majeed, Kamran [4 ,5 ]
Sarathy, Kiran [1 ]
Jung, Richard G. [1 ,2 ]
Feder, Joshua [1 ]
Ramirez, F. Daniel [1 ,6 ,7 ]
Di Santo, Pietro [1 ]
Marbach, Jeffrey [1 ]
Dhaliwal, Shan [1 ]
Short, Spencer [1 ]
Labinaz, Alisha [1 ]
Schultz, Carl [4 ,5 ]
Russo, Juan J. [1 ]
So, Derek [1 ]
Chong, Aun-Yeong [1 ]
Le May, Michel [1 ]
Hibbert, Benjamin [1 ,2 ]
机构
[1] Univ Ottawa, Div Cardiol, Capital Res Grp, Heart Inst, Ottawa, ON, Canada
[2] Univ Ottawa, Dept Cellular & Mol Med, Ottawa, ON, Canada
[3] Univ Calgary, Cumming Sch Med, Calgary, AB, Canada
[4] Royal Perth Hosp, Dept Cardiol, Perth, WA, Australia
[5] Univ Western Australia, Sch Med, Perth, WA, Australia
[6] CHU Bordeaux, Hop Cardiol Haut Leveque, Bordeaux, France
[7] Univ Bordeaux, Inst Rythmol & Modelisat Cardiaque LIRYC, Bordeaux, France
来源
PLOS ONE | 2020年 / 15卷 / 08期
基金
加拿大健康研究院;
关键词
STENTS; MODELS; SALINE;
D O I
10.1371/journal.pone.0237588
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background Coronary revascularization using imaging guidance is rapidly becoming the standard of care. Intravascular optical coherence tomography uses near-infrared light to obtain high resolution intravascular images. Standard optical coherence tomography imaging technique employs iodinated contrast dye to achieve the required blood clearance during acquisition. We sought to systematically evaluate the technical performance of saline as an alternative to iodinated contrast for intravascular optical coherence tomography assessment. Methods and results We performed bench top optical coherence tomography analysis on nylon tubing with sequential contrast/saline dilutions to empirically derive adjustment coefficients. We then applied these coefficientsin vivoin an established rabbit abdominal stenting model with both saline and contrast optical coherence tomography imaging. In this model, we assessed the impact of saline on both quantitative and qualitative vessel assessment. Nylon tubing assessment demonstrated a linear relationship between saline and contrast for both area and diameter. We then derived adjustment coefficients, allowing for accurate calculation of area and diameter when converting saline into both contrast and reference dimensions.In vivostudies confirmed reduced area with saline versus contrast [7.43 (5.67-8.36) mm(2)versus 8.2 (6.34-9.39) mm(2), p = 0.001] and diameter [3.08 mm versus 3.23 mm, p = 0.001]. Following correction, a strong relationship was achievedin vivobetween saline and contrast in both area and diameter without compromising image quality, artefact, or strut assessment. Conclusion Saline generates reduced dimensions compared to contrast during intravascular optical coherence tomography imaging. The relationship across physiologic coronary diameters is linear and can be corrected with high fidelity. Saline does not adversely impact image quality, artefact, or strut assessment.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Feasibility of Non-Contrast Optical Coherence Tomography Imaging in Coronary Arteries
    Kang, Dong
    Nam, Hyeong Soo
    Kim, Sunwon
    Yoo, Hongki
    Kim, Jin Won
    CIRCULATION, 2021, 144
  • [2] Are Non-Contrast Flushing Agents in Coronary Artery Optical Coherence Tomography Feasible Alternatives to Contrast Flushing?
    Egeland, C. H.
    Meyerdierks, O.
    Fossum, E.
    Brekke, M.
    Opdahl, A.
    CARDIOLOGY, 2013, 125 : 24 - 25
  • [3] Feasibility and Safety of Non-contrast Optical Coherence Tomography Imaging in Coronary Arteries
    Kang, Dong Oh
    Nam, Hyeong Soo
    Kim, Sun Won
    Yoo, Hongki
    Kim, Jin Won
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2022, 79 (15) : S33 - S34
  • [4] Feasibility and Safety of Non-Contrast Optical Coherence Tomography Imaging Using Hydroxyethyl Starch in Coronary Arteries
    Kang, Dong Oh
    Nam, Hyeong Soo
    Kim, Sunwon
    Yoo, Hongki
    Kim, Jin W.
    CIRCULATION, 2022, 146
  • [5] Feasibility and safety of non-contrast optical coherence tomography imaging using hydroxyethyl starch in coronary arteries
    Dong Oh Kang
    Hyeong Soo Nam
    Sunwon Kim
    Hongki Yoo
    Jin Won Kim
    Scientific Reports, 13 (1)
  • [6] Feasibility and safety of non-contrast optical coherence tomography imaging using hydroxyethyl starch in coronary arteries
    Kang, Dong Oh
    Nam, Hyeong Soo
    Kim, Sunwon
    Yoo, Hongki
    Kim, Jin Won
    SCIENTIFIC REPORTS, 2023, 13 (01):
  • [7] Feasibility of morphological assessment of coronary artery calcification with electrocardiography-gated non-contrast computed tomography: a comparative study with optical coherence tomography
    Yu Takahashi
    Takayoshi Toba
    Hiromasa Otake
    Yusuke Fukuyama
    Shinsuke Nakano
    Yoichiro Matsuoka
    Kosuke Tanimura
    Yu Izawa
    Hiroyuki Kawamori
    Atsushi K. Kono
    Sei Fujiwara
    Ken-ichi Hirata
    The International Journal of Cardiovascular Imaging, 2021, 37 : 1445 - 1453
  • [8] Feasibility of morphological assessment of coronary artery calcification with electrocardiography-gated non-contrast computed tomography: a comparative study with optical coherence tomography
    Takahashi, Yu
    Toba, Takayoshi
    Otake, Hiromasa
    Fukuyama, Yusuke
    Nakano, Shinsuke
    Matsuoka, Yoichiro
    Tanimura, Kosuke
    Izawa, Yu
    Kawamori, Hiroyuki
    Kono, Atsushi K.
    Fujiwara, Sei
    Hirata, Ken-ichi
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2021, 37 (04): : 1445 - 1453
  • [9] Contrast phantoms for optical coherence tomography
    Woolliams, Peter D.
    Tomlins, Peter H.
    DESIGN AND PERFORMANCE VALIDATION OF PHANTOMS USED IN CONJUNCTION WITH OPTICAL MEASUREMENT OF TISSUE II, 2010, 7567
  • [10] Contrast and resolution in optical coherence tomography
    Hellmuth, T
    OPTICAL BIOPSIES AND MICROSCOPIC TECHNIQUES, PROCEEDINGS OF, 1996, 2926 : 228 - 237