Contrast-free optical coherence tomography:Systematic evaluation of non-contrast media for intravascular assessment

被引:6
|
作者
Simard, Trevor [1 ,2 ]
Motazedian, Pouya [1 ,3 ]
Majeed, Kamran [4 ,5 ]
Sarathy, Kiran [1 ]
Jung, Richard G. [1 ,2 ]
Feder, Joshua [1 ]
Ramirez, F. Daniel [1 ,6 ,7 ]
Di Santo, Pietro [1 ]
Marbach, Jeffrey [1 ]
Dhaliwal, Shan [1 ]
Short, Spencer [1 ]
Labinaz, Alisha [1 ]
Schultz, Carl [4 ,5 ]
Russo, Juan J. [1 ]
So, Derek [1 ]
Chong, Aun-Yeong [1 ]
Le May, Michel [1 ]
Hibbert, Benjamin [1 ,2 ]
机构
[1] Univ Ottawa, Div Cardiol, Capital Res Grp, Heart Inst, Ottawa, ON, Canada
[2] Univ Ottawa, Dept Cellular & Mol Med, Ottawa, ON, Canada
[3] Univ Calgary, Cumming Sch Med, Calgary, AB, Canada
[4] Royal Perth Hosp, Dept Cardiol, Perth, WA, Australia
[5] Univ Western Australia, Sch Med, Perth, WA, Australia
[6] CHU Bordeaux, Hop Cardiol Haut Leveque, Bordeaux, France
[7] Univ Bordeaux, Inst Rythmol & Modelisat Cardiaque LIRYC, Bordeaux, France
来源
PLOS ONE | 2020年 / 15卷 / 08期
基金
加拿大健康研究院;
关键词
STENTS; MODELS; SALINE;
D O I
10.1371/journal.pone.0237588
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background Coronary revascularization using imaging guidance is rapidly becoming the standard of care. Intravascular optical coherence tomography uses near-infrared light to obtain high resolution intravascular images. Standard optical coherence tomography imaging technique employs iodinated contrast dye to achieve the required blood clearance during acquisition. We sought to systematically evaluate the technical performance of saline as an alternative to iodinated contrast for intravascular optical coherence tomography assessment. Methods and results We performed bench top optical coherence tomography analysis on nylon tubing with sequential contrast/saline dilutions to empirically derive adjustment coefficients. We then applied these coefficientsin vivoin an established rabbit abdominal stenting model with both saline and contrast optical coherence tomography imaging. In this model, we assessed the impact of saline on both quantitative and qualitative vessel assessment. Nylon tubing assessment demonstrated a linear relationship between saline and contrast for both area and diameter. We then derived adjustment coefficients, allowing for accurate calculation of area and diameter when converting saline into both contrast and reference dimensions.In vivostudies confirmed reduced area with saline versus contrast [7.43 (5.67-8.36) mm(2)versus 8.2 (6.34-9.39) mm(2), p = 0.001] and diameter [3.08 mm versus 3.23 mm, p = 0.001]. Following correction, a strong relationship was achievedin vivobetween saline and contrast in both area and diameter without compromising image quality, artefact, or strut assessment. Conclusion Saline generates reduced dimensions compared to contrast during intravascular optical coherence tomography imaging. The relationship across physiologic coronary diameters is linear and can be corrected with high fidelity. Saline does not adversely impact image quality, artefact, or strut assessment.
引用
收藏
页数:15
相关论文
共 50 条
  • [41] NON-CONTRAST MRI FOR ASSESSMENT OF THORACIC AORTA DIMENSION
    Gupta, Mehak
    Clarke, Hannah
    Hargreaves, Oscar
    Ingram, Tom
    Pakala, Vijay
    Lee, Eveline
    Otun, Jemiliat
    HEART, 2021, 107 : A137 - A137
  • [42] PSEUDO-HYDRONEPHROSIS ON NON-CONTRAST COMPUTED-TOMOGRAPHY
    AMIS, ES
    CRONAN, JJ
    PFISTER, RC
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1982, 6 (03) : 511 - 513
  • [43] Detection of Ischemic Infarct Core in Non-contrast Computed Tomography
    Hornung, Maximilian
    Taubmann, Oliver
    Ditt, Hendrik
    Menze, Bjorn
    Herman, Pawel
    Fransen, Erik
    MACHINE LEARNING IN MEDICAL IMAGING, MLMI 2020, 2020, 12436 : 260 - 269
  • [44] Utility of non-contrast head computed tomography in poisoned patients
    McNulty, Richard
    Bandaranayake, Lashnika
    Wong, Timothy
    Garner, Alex
    Tahmid, Farhan
    Symes, Emily
    Mohammad, Mohammad
    Salter, Mark
    Gunja, Naren
    EMERGENCY MEDICINE AUSTRALASIA, 2021, 33 (05) : 888 - 892
  • [45] Coronary Endothelial Dysfunction and Non-Contrast Multidetector Computed Tomography
    Kurata, Akira
    Higashino, Hiroshi
    Mochizuki, Teruhito
    CIRCULATION JOURNAL, 2012, 76 (01) : 45 - 46
  • [46] Non-contrast Spiral Computed Tomography in Diagnosis of Acute Appendicitis
    Pakaneh, M. A.
    Fazeli, M. S.
    Ghanaati, H.
    Kaviani, A.
    Aminian, A.
    Zobeiri, T.
    Bashashati, M.
    IRANIAN JOURNAL OF RADIOLOGY, 2008, 5 (01) : 1 - 6
  • [47] The utility of non-contrast head computed tomography in poisoned patients
    McNulty, Richard
    Garner, Alex
    Wong, Timothy
    Bandaranayake, Lashnika
    Tahmid, Farhan
    Symes, Emily
    Mohammad, Mohammad
    Salter, Mark
    Gunja, Naren
    CLINICAL TOXICOLOGY, 2019, 57 (06) : 584 - 585
  • [48] Engineered microsphere contrast agents for optical coherence tomography
    Lee, TM
    Oldenburg, AL
    Sitafalwalla, S
    Marks, DL
    Luo, W
    Toublan, FJJ
    Suslick, KS
    Boppart, SA
    OPTICS LETTERS, 2003, 28 (17) : 1546 - 1548
  • [49] Contrast-enhanced intraoperative optical coherence tomography
    Ehlers, Justis P.
    McNutt, Stephen A.
    Kaiser, Peter K.
    Srivastava, Sunil K.
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2013, 97 (11) : 1384 - 1386
  • [50] Magnetic and Plasmonic Contrast Agents in Optical Coherence Tomography
    Oldenburg, Amy L.
    Blackmon, Richard L.
    Sierchio, Justin M.
    IEEE JOURNAL OF SELECTED TOPICS IN QUANTUM ELECTRONICS, 2016, 22 (04) : 133 - 145