Contrast-free optical coherence tomography:Systematic evaluation of non-contrast media for intravascular assessment

被引:6
|
作者
Simard, Trevor [1 ,2 ]
Motazedian, Pouya [1 ,3 ]
Majeed, Kamran [4 ,5 ]
Sarathy, Kiran [1 ]
Jung, Richard G. [1 ,2 ]
Feder, Joshua [1 ]
Ramirez, F. Daniel [1 ,6 ,7 ]
Di Santo, Pietro [1 ]
Marbach, Jeffrey [1 ]
Dhaliwal, Shan [1 ]
Short, Spencer [1 ]
Labinaz, Alisha [1 ]
Schultz, Carl [4 ,5 ]
Russo, Juan J. [1 ]
So, Derek [1 ]
Chong, Aun-Yeong [1 ]
Le May, Michel [1 ]
Hibbert, Benjamin [1 ,2 ]
机构
[1] Univ Ottawa, Div Cardiol, Capital Res Grp, Heart Inst, Ottawa, ON, Canada
[2] Univ Ottawa, Dept Cellular & Mol Med, Ottawa, ON, Canada
[3] Univ Calgary, Cumming Sch Med, Calgary, AB, Canada
[4] Royal Perth Hosp, Dept Cardiol, Perth, WA, Australia
[5] Univ Western Australia, Sch Med, Perth, WA, Australia
[6] CHU Bordeaux, Hop Cardiol Haut Leveque, Bordeaux, France
[7] Univ Bordeaux, Inst Rythmol & Modelisat Cardiaque LIRYC, Bordeaux, France
来源
PLOS ONE | 2020年 / 15卷 / 08期
基金
加拿大健康研究院;
关键词
STENTS; MODELS; SALINE;
D O I
10.1371/journal.pone.0237588
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background Coronary revascularization using imaging guidance is rapidly becoming the standard of care. Intravascular optical coherence tomography uses near-infrared light to obtain high resolution intravascular images. Standard optical coherence tomography imaging technique employs iodinated contrast dye to achieve the required blood clearance during acquisition. We sought to systematically evaluate the technical performance of saline as an alternative to iodinated contrast for intravascular optical coherence tomography assessment. Methods and results We performed bench top optical coherence tomography analysis on nylon tubing with sequential contrast/saline dilutions to empirically derive adjustment coefficients. We then applied these coefficientsin vivoin an established rabbit abdominal stenting model with both saline and contrast optical coherence tomography imaging. In this model, we assessed the impact of saline on both quantitative and qualitative vessel assessment. Nylon tubing assessment demonstrated a linear relationship between saline and contrast for both area and diameter. We then derived adjustment coefficients, allowing for accurate calculation of area and diameter when converting saline into both contrast and reference dimensions.In vivostudies confirmed reduced area with saline versus contrast [7.43 (5.67-8.36) mm(2)versus 8.2 (6.34-9.39) mm(2), p = 0.001] and diameter [3.08 mm versus 3.23 mm, p = 0.001]. Following correction, a strong relationship was achievedin vivobetween saline and contrast in both area and diameter without compromising image quality, artefact, or strut assessment. Conclusion Saline generates reduced dimensions compared to contrast during intravascular optical coherence tomography imaging. The relationship across physiologic coronary diameters is linear and can be corrected with high fidelity. Saline does not adversely impact image quality, artefact, or strut assessment.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] Motion Contrast Optical Coherence Tomography Angiography
    Li, Pei
    Zhou, Liping
    Ni, Yang
    Cheng, Yuxuan
    Ding, Zhihua
    Li, Peng
    2016 ASIA COMMUNICATIONS AND PHOTONICS CONFERENCE (ACP), 2016,
  • [22] Nanoshells as an optical coherence tomography contrast agent
    Barton, JK
    Halas, NJ
    West, JL
    Drezek, RA
    COHERENCE DOMAIN OPTICAL METHODS AND OPTICAL COHERENCE TOMOGRAPHY IN BIOMEDICINE VIII, 2004, 5316 : 99 - 106
  • [23] Magnetic contrast agents for optical coherence tomography
    Oldenburg, AL
    Gunther, JR
    Toublan, FJJ
    Marks, DL
    Suslick, KS
    Boppart, SA
    COHERENCE DOMAIN OPTICAL METHODS AND OPTICAL COHERENCE TOMOGRAPHY IN BIOMEDICINE VIII, 2004, 5316 : 91 - 98
  • [24] Advances in contrast enhancement for optical coherence tomography
    Boppart, Stephen A.
    2006 28th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, Vols 1-15, 2006, : 3962 - 3965
  • [25] Nanoparticles for Enhanced Contrast Optical Coherence Tomography
    Maule, Cesar D.
    Quaresma, Pedro
    Carvalho, Patricia A.
    Jorge, Pedro
    Pereira, Eulalia
    Rosa, Carla C.
    1ST CANTERBURY WORKSHOP ON OPTICAL COHERENCE TOMOGRAPHY AND ADAPTIVE OPTICS, 2008, 7139
  • [26] Evaluating anemia on non-contrast thoracic computed tomography
    Abbasi, Bita
    Hosseini, Maliheh Seyed
    Ghalibaf, AmirAli Moodi
    Akhavan, Reza
    Emadzadeh, Maryam
    Bolvardi, Ehsan
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [27] Molecular contrast optical coherence tomography: A review
    Yang, CH
    PHOTOCHEMISTRY AND PHOTOBIOLOGY, 2005, 81 (02) : 215 - 237
  • [28] Magnetomotive contrast for in vivo optical coherence tomography
    Oldenburg, AL
    Toublan, FJJ
    Suslick, KS
    Wei, A
    Boppart, SA
    OPTICS EXPRESS, 2005, 13 (17): : 6597 - 6614
  • [29] Differential phase contrast in optical coherence tomography
    Hitzenberger, CK
    Fercher, AF
    OPTICS LETTERS, 1999, 24 (09) : 622 - 624
  • [30] Differential phase contrast in optical coherence tomography
    Institute of Medical Physics, University of Vienna, Währinger Strasse 13, A-1090 Vienna, Austria
    Opt. Lett., 9 (622-624):