Contrast-free optical coherence tomography:Systematic evaluation of non-contrast media for intravascular assessment

被引:6
|
作者
Simard, Trevor [1 ,2 ]
Motazedian, Pouya [1 ,3 ]
Majeed, Kamran [4 ,5 ]
Sarathy, Kiran [1 ]
Jung, Richard G. [1 ,2 ]
Feder, Joshua [1 ]
Ramirez, F. Daniel [1 ,6 ,7 ]
Di Santo, Pietro [1 ]
Marbach, Jeffrey [1 ]
Dhaliwal, Shan [1 ]
Short, Spencer [1 ]
Labinaz, Alisha [1 ]
Schultz, Carl [4 ,5 ]
Russo, Juan J. [1 ]
So, Derek [1 ]
Chong, Aun-Yeong [1 ]
Le May, Michel [1 ]
Hibbert, Benjamin [1 ,2 ]
机构
[1] Univ Ottawa, Div Cardiol, Capital Res Grp, Heart Inst, Ottawa, ON, Canada
[2] Univ Ottawa, Dept Cellular & Mol Med, Ottawa, ON, Canada
[3] Univ Calgary, Cumming Sch Med, Calgary, AB, Canada
[4] Royal Perth Hosp, Dept Cardiol, Perth, WA, Australia
[5] Univ Western Australia, Sch Med, Perth, WA, Australia
[6] CHU Bordeaux, Hop Cardiol Haut Leveque, Bordeaux, France
[7] Univ Bordeaux, Inst Rythmol & Modelisat Cardiaque LIRYC, Bordeaux, France
来源
PLOS ONE | 2020年 / 15卷 / 08期
基金
加拿大健康研究院;
关键词
STENTS; MODELS; SALINE;
D O I
10.1371/journal.pone.0237588
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background Coronary revascularization using imaging guidance is rapidly becoming the standard of care. Intravascular optical coherence tomography uses near-infrared light to obtain high resolution intravascular images. Standard optical coherence tomography imaging technique employs iodinated contrast dye to achieve the required blood clearance during acquisition. We sought to systematically evaluate the technical performance of saline as an alternative to iodinated contrast for intravascular optical coherence tomography assessment. Methods and results We performed bench top optical coherence tomography analysis on nylon tubing with sequential contrast/saline dilutions to empirically derive adjustment coefficients. We then applied these coefficientsin vivoin an established rabbit abdominal stenting model with both saline and contrast optical coherence tomography imaging. In this model, we assessed the impact of saline on both quantitative and qualitative vessel assessment. Nylon tubing assessment demonstrated a linear relationship between saline and contrast for both area and diameter. We then derived adjustment coefficients, allowing for accurate calculation of area and diameter when converting saline into both contrast and reference dimensions.In vivostudies confirmed reduced area with saline versus contrast [7.43 (5.67-8.36) mm(2)versus 8.2 (6.34-9.39) mm(2), p = 0.001] and diameter [3.08 mm versus 3.23 mm, p = 0.001]. Following correction, a strong relationship was achievedin vivobetween saline and contrast in both area and diameter without compromising image quality, artefact, or strut assessment. Conclusion Saline generates reduced dimensions compared to contrast during intravascular optical coherence tomography imaging. The relationship across physiologic coronary diameters is linear and can be corrected with high fidelity. Saline does not adversely impact image quality, artefact, or strut assessment.
引用
收藏
页数:15
相关论文
共 50 条
  • [31] Type A Aortic Dissection and Non-Contrast Computed Tomography
    Spangenberg, Amelie
    Rao, Shiavax J.
    Mackrell, John
    Rimm, Sarah
    Haas, Christopher J.
    JOURNAL OF COMMUNITY HOSPITAL INTERNAL MEDICINE PERSPECTIVES, 2023, 13 (03): : 119 - 120
  • [32] Is Non-Contrast CT Adequate for the Evaluation of Hepatic Metastasis in Patients Who Cannot Receive Iodinated Contrast Media?
    Jee, Han Bum
    Park, Min Jung
    Lee, Hye Sun
    Park, Mi-Suk
    Kim, Myeong-Jin
    Chung, Yong Eun
    PLOS ONE, 2015, 10 (07):
  • [34] Dextran or Saline Can Replace Contrast for Intravascular Optical Coherence Tomography in Lower Extremity Arteries
    Kendrick, Daniel E.
    Allemang, Matthew T.
    Gosling, Andre F.
    Nagavalli, Anil
    Kim, Ann H.
    Nishino, Setsu
    Parikh, Sahil A.
    Bezerra, Hiram G.
    Kashyap, Vikram S.
    JOURNAL OF ENDOVASCULAR THERAPY, 2016, 23 (05) : 723 - 730
  • [35] Quantitative assessment of ensemble coherency in contrast-free ultrasound microvasculature imaging
    Nayak, Rohit
    MacNeill, Justin
    Flores, Cecilia
    Webb, Jeremy
    Fatemi, Mostafa
    Alizad, Azra
    MEDICAL PHYSICS, 2021, 48 (07) : 3540 - 3558
  • [36] Assessment of Vessel Density on Non-Contrast Computed Tomography to Detect Basilar Artery Occlusion
    Asimos, Andrew W.
    Sassano, D. Richard
    Jackson, Stephen C.
    Clemente, Jonathan D.
    Rhoten, Jeremy B.
    Chang, Brenda
    Runyon, Michael S.
    WESTERN JOURNAL OF EMERGENCY MEDICINE, 2020, 21 (03) : 694 - 702
  • [37] Zero contrast optical coherence tomography-guided percutaneous coronary intervention for in-stent restenosis of the saphenous vein graft using a non-contrast flush medium
    Vasu, Nandhakumar
    Subban, Vijayakumar
    Mullasari, S. Ajit
    INDIAN HEART JOURNAL, 2018, 70 : S492 - S495
  • [38] Non-Contrast and Contrast-Enhanced Cardiac Computed Tomography Imaging in the Diagnostic and Prognostic Evaluation of Coronary Artery Disease
    Pugliese, Luca
    Ricci, Francesca
    Sica, Giacomo
    Scaglione, Mariano
    Masala, Salvatore
    DIAGNOSTICS, 2023, 13 (12)
  • [39] Contrast-free microscopic assessment of glioblastoma bioposy specimens prior to biobanking
    Georges, Joseph
    Zehri, Aqib
    Carlson, Elizabeth
    Nichols, Joshua
    Mooney, Michael A.
    Martirosyan, Nikolay L.
    Ghaffari, Layla
    Kalani, M. Yashar S.
    Eschbacher, Jennifer
    Feuerstein, Burt
    Anderson, Trent
    Preul, Mark C.
    Van Keuren-Jensen, Kendall
    Nakaji, Peter
    NEUROSURGICAL FOCUS, 2014, 36 (02)
  • [40] Evaluation of pancreatic steatosis prevalence and anthropometric measurements using non-contrast computed tomography
    Koc, Ural
    Taydas, Onur
    TURKISH JOURNAL OF GASTROENTEROLOGY, 2020, 31 (09): : 640 - 648