Feasibility and safety of non-contrast optical coherence tomography imaging using hydroxyethyl starch in coronary arteries

被引:0
|
作者
Dong Oh Kang
Hyeong Soo Nam
Sunwon Kim
Hongki Yoo
Jin Won Kim
机构
[1] Korea University Guro Hospital,Multimodal Imaging and Theranostic Laboratory, Cardiovascular Center
[2] Korea University Guro Hospital,Cardiovascular Center
[3] Korea Advanced Institute of Science and Technology,Department of Mechanical Engineering
[4] Korea University Ansan Hospital,Cardiovascular Center
关键词
D O I
暂无
中图分类号
学科分类号
摘要
Intracoronary optical coherence tomography (OCT) requires injection of flushing media for image acquisition. Alternative flushing media needs to be investigated to reduce the risk of contrast-induced renal dysfunction. We investigated the feasibility and safety of pentastarch (hydroxyethyl starch) for clinical OCT imaging. We prospectively enrolled 43 patients with 70 coronary lesions (46-stented; 24-native). Total 81 OCT pullback pairs were obtained by manual injection of iodine contrast, followed by pentastarch. Each pullback was assessed frame-by-frame using an automated customized lumen contour/stent strut segmentation algorithm. Paired images were compared for the clear image segments (CIS), blood-flushing capability, and quantitative morphometric measurements. Overall image quality, as assessed by the proportion of CIS, was comparable between the contrast- and pentastarch-flushed images (97.1% vs. 96.5%; p = 0.160). The pixel-based blood-flushing capability was similar between the groups (0.951 [0.947–0.953] vs. 0.950 [0.948–0.952], p = 0.125). Quantitative two- and three-dimensional morphometric measurements of the paired images correlated well (p < 0.001) with excellent inter-measurement variability. All patients safely underwent OCT imaging using pentastarch without resulting in clinically relevant complications or renal deterioration. Non-contrast OCT imaging using pentastarch is clinically safe and technically feasible with excellent image quality and could be a promising alternative strategy for patients at high risk of renal impairment.
引用
下载
收藏
相关论文
共 50 条
  • [41] Endovascular optical coherence tomography imaging of normal carotid arteries
    Mathews, Marlon S.
    Nwagwu, Chiedozie I.
    Su, Jianping
    Chen, Zhongping
    Tromberg, Bruce J.
    Linskey, Mark E.
    JOURNAL OF NEUROSURGERY, 2007, 106 (05) : A943 - A943
  • [42] High-resolution coronary imaging by optical coherence tomography: Feasibility, pitfalls and artefact analysis
    Motreff, Pascal
    Levesque, Sebastien
    Souteyrand, Geraud
    Sarry, Laurent
    Ouchchane, Lemlih
    Citron, Bernard
    Cassagnes, Jean
    Lusson, Jean-Rene
    ARCHIVES OF CARDIOVASCULAR DISEASES, 2010, 103 (04) : 215 - 226
  • [43] Optical Coherence Tomography in Carotid Artery Stenting: Feasibility and Safety
    Krishnan, Sandeep
    Nakamura, Mamoo
    Jilaihawi, Hasan
    Dohad, Suhail
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 64 (11) : B163 - B163
  • [44] Safety and Feasibility of Optical Coherence Tomography: A Single Center Experience
    van der Sijde, Jors
    Karanasos, Antonios
    van Soest, Gijs
    Van Mieghem, Nicolas M.
    De Jaegere, Peter
    Van Geuns, Robert J.
    Diletti, Roberto
    Zijlstra, Felix
    Van Domburg, Ron
    Regar, Evelyn
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 64 (11) : B112 - B112
  • [45] Optical Coherence Tomography Imaging in Acute Coronary Syndromes
    Kubo, Takashi
    Ino, Yasushi
    Tanimoto, Takashi
    Kitabata, Hironori
    Tanaka, Atsushi
    Akasaka, Takashi
    CARDIOLOGY RESEARCH AND PRACTICE, 2011, 2011
  • [46] Imaging and characterization of coronary lesions with optical coherence tomography
    Schmitt, JM
    Petersen, CL
    Mont, E
    Virmani, R
    2002 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING, PROCEEDINGS, 2002, : 106 - 109
  • [47] Optical Coherence Tomography Imaging of Takayasu Coronary Arteritis
    Amsallem, Myriam
    Henry, Patrick
    Silberman, Stephane Manzo
    CANADIAN JOURNAL OF CARDIOLOGY, 2014, 30 (04) : 464.e13 - 464.e14
  • [48] FEASIBILITY OF OPTICAL CORONARY TOMOGRAPHY IN QUANTITATIVE MEASUREMENT OF CORONARY ARTERIES WITH LIPIDIC PLAQUE
    Katayama, Yosuke
    Shiono, Yasutsugu
    Orii, Makoto
    Yamano, Takashi
    Matsuo, Yoshiki
    Ino, Yasushi
    Ino, Yasushi
    Yamaguchi, Tomoyuki
    Kubo, Takashi
    Tanaka, Atsushi
    Shioji, Syusaku
    Hashizume, Toshikazu
    Akasaka, Takashi
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 65 (10) : A1842 - A1842
  • [49] Porcine coronary imaging in vivo by optical coherence tomography
    Tearney, GJ
    Jang, IK
    Kang, DH
    Aretz, HT
    Houser, SL
    Brady, TJ
    Schlendorf, K
    Shishkov, M
    Bouma, BE
    ACTA CARDIOLOGICA, 2000, 55 (04) : 233 - 237
  • [50] Reconstruction of stented coronary arteries from optical coherence tomography images: Feasibility, validation, and repeatability of a segmentation method
    Chiastra, Claudio
    Montin, Eros
    Bologna, Marco
    Migliori, Susanna
    Aurigemma, Cristina
    Burzotta, Francesco
    Celi, Simona
    Dubini, Gabriele
    Migliavacca, Francesco
    Mainardi, Luca
    PLOS ONE, 2017, 12 (06):