Intracoronary optical coherence tomography (OCT) requires injection of flushing media for image acquisition. Alternative flushing media needs to be investigated to reduce the risk of contrast-induced renal dysfunction. We investigated the feasibility and safety of pentastarch (hydroxyethyl starch) for clinical OCT imaging. We prospectively enrolled 43 patients with 70 coronary lesions (46-stented; 24-native). Total 81 OCT pullback pairs were obtained by manual injection of iodine contrast, followed by pentastarch. Each pullback was assessed frame-by-frame using an automated customized lumen contour/stent strut segmentation algorithm. Paired images were compared for the clear image segments (CIS), blood-flushing capability, and quantitative morphometric measurements. Overall image quality, as assessed by the proportion of CIS, was comparable between the contrast- and pentastarch-flushed images (97.1% vs. 96.5%; p = 0.160). The pixel-based blood-flushing capability was similar between the groups (0.951 [0.947–0.953] vs. 0.950 [0.948–0.952], p = 0.125). Quantitative two- and three-dimensional morphometric measurements of the paired images correlated well (p < 0.001) with excellent inter-measurement variability. All patients safely underwent OCT imaging using pentastarch without resulting in clinically relevant complications or renal deterioration. Non-contrast OCT imaging using pentastarch is clinically safe and technically feasible with excellent image quality and could be a promising alternative strategy for patients at high risk of renal impairment.
引用
下载
收藏
相关论文
共 50 条
  • [31] Optical coherence tomography in pulmonary imaging: Feasibility study
    Jung, W
    Zhang, J
    Wilder-Smith, P
    Reza, M
    Brenner, M
    Shin, Y
    Nelson, JS
    Chen, Z
    COHERENCE DOMAIN OPTICAL METHODS AND OPTICAL COHERENCE TOMOGRAPHY IN BIOMEDICINE VIII, 2004, 5316 : 48 - 55
  • [32] Histopathological validation of optical coherence tomography findings of the coronary arteries
    Fujii, Kenichi
    Kawakami, Rika
    Hirota, Seiichi
    JOURNAL OF CARDIOLOGY, 2018, 72 (3-4) : 179 - 185
  • [33] Safety and Feasibility of Non-occlusion Image Acquisition Technique for Optical Coherence Tomography
    Kataiwa, Hideaki
    Tanaka, Atsushi
    Kitabata, Hironori
    Tanimoto, Takashi
    Takarada, Shigeho
    Nakamura, Nobuo
    Hirata, Kumiko
    Mizukoshi, Masato
    Imanishi, Toshio
    Akasaka, Takashi
    AMERICAN JOURNAL OF CARDIOLOGY, 2008, 102 (8A): : 197I - 197I
  • [34] Non-Contrast and Contrast-Enhanced Cardiac Computed Tomography Imaging in the Diagnostic and Prognostic Evaluation of Coronary Artery Disease
    Pugliese, Luca
    Ricci, Francesca
    Sica, Giacomo
    Scaglione, Mariano
    Masala, Salvatore
    DIAGNOSTICS, 2023, 13 (12)
  • [35] Feasibility study of normal and septic tracheal imaging using optical coherence tomography
    Jung, W
    Zhang, J
    Mina-Araghi, R
    Hanna, N
    Brenner, M
    Nelson, JS
    Chen, ZP
    LASERS IN SURGERY AND MEDICINE, 2004, 35 (02) : 121 - 127
  • [36] Feasibility of Endomyocardial Imaging Using Optical Coherence Tomography For the Diagnosis of Myocardial Disease
    Tsay, David
    Gan, Yu
    Marboe, Charles C.
    Hendon, Christine
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 64 (11) : B111 - B111
  • [37] A Feasibility Study of the DyeVert™ Plus Contrast Reduction System to Reduce Contrast Media Volumes in Percutaneous Coronary Procedures Using Optical Coherence Tomography
    Zimin, Vladislav N.
    Jones, Michael R.
    Tyler, Richmond
    Durieux, Jared C.
    Alaiti, Amer M.
    Pereira, Gabriel Tensol R.
    Vergara-Martel, Armando
    Pizzato, Patricia E.
    Zago, Elder, I
    Dallan, Luis A.
    Bezerra, Hiram G.
    CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2021, 30 : 40 - 46
  • [38] Real-time, in vivo optical coherence tomography of human coronary arteries using a dedicated imaging wire.
    Regar, E
    Schaar, J
    van der Giessen, W
    van der Steen, A
    Serruys, PW
    AMERICAN JOURNAL OF CARDIOLOGY, 2002, 90 (6A): : 129H - 130H
  • [39] Endovascular optical coherence tomography imaging of normal carotid arteries
    Mathews, Marlon S.
    Nwagwu, Chiedozie I.
    Su, Jianping
    Chen, Zhongping
    Tromberg, Bruce J.
    Linskey, Mark E.
    STROKE, 2007, 38 (02) : 455 - 455
  • [40] Imaging of carotid arteries with optical coherence tomography and correlation with histology
    Schlendorf, KH
    Houser, SL
    Bouma, BE
    Koroshetz, WJ
    Tearney, GJ
    CIRCULATION, 2000, 102 (18) : 729 - 729