Surgical repair of leaking filtering blebs

被引:43
|
作者
Wadhwani, RA
Bellows, AR
Hutchinson, BT
机构
[1] Harvard Univ, Sch Med, Dept Ophthalmol, Cambridge, MA 02138 USA
[2] Ophthalm Consultants Boston, Boston, MA 02114 USA
[3] Tufts Univ, Sch Med, New England Eye Ctr, Dept Ophthalmol, Boston, MA 02111 USA
关键词
D O I
10.1016/S0161-6420(00)00282-7
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To report the surgical management of leaking filtering blebs occurring after blebitis or persistent hypotony. Design: Retrospective, noncomparative case series. Participants: Twenty-two eyes of 20 patients with late bleb leak, blebitis or endophthalmitis, hypotony maculopathy, or bleb dysesthesia on presentation to the glaucoma service who required surgical bleb revision from 1990 through 1999. Intervention: Pedicle flap, partial excision, and advancement or free conjunctival autologous graft techniques for surgical bleb revision. Type of bleb revision was dependent on the dimensions of the bleb and quality. of surrounding conjunctiva. Main Outcome Measurer Preoperative and postoperative intraocular pressure (IOP), status of bleb leak, reoperation for glaucoma, or requirement for postrevision glaucoma medical therapy, with success defined as the need for two or fewer glaucoma medications after revision. Results: Eighty-six percent (19/22) of eyes that underwent surgical bleb revision had resolution of leak and IOP control using two or fewer medications after one or more bleb revisions. The preoperative IOP (mean +/- standard deviation) was 3.7 +/- 2.6 mmHg (range, 0-8 mmHg). After an average follow-up of 21 months (range, 8-108 months), the IOP was 11.0 +/- 4.4 mmHg for patients taking 0.6 +/- 1.0 glaucoma medications. Eighteen percent (4/22) of eyes required two or more bleb revisions. In one eye, an IOP spike of 36 mmHg developed after revision, which required laser suture lysis on two occasions before the IOP was significantly lowered. The three failures were: one eye that required three or more medications for IOP control, a patient whose eye had a persistent leak after revision and who was not mentally competent to undergo repeat revision, and one eye that required combined glaucoma and cataract surgery after revision. Conclusions: Surgical bleb revision has a high success rate of closing late bleb leaks, maintaining glaucoma control, and preserving vision, with few postoperative complications. The appropriate surgical procedure for revision must be based on the individual clinical situation and can result in successful bleb revision. Ophthalmology 2000;107:1681-1687 (C) 2000 by the American Academy of Ophthalmology.
引用
收藏
页码:1681 / 1687
页数:7
相关论文
共 50 条
  • [1] A SURGICAL METHOD TO REPAIR LEAKING FILTERING BLEBS
    OCONNOR, DJ
    TRESSLER, CS
    CAPRIOLI, J
    [J]. OPHTHALMIC SURGERY AND LASERS, 1992, 23 (05): : 336 - 338
  • [2] Surgical repair of leaking filtering blebs - Discussion
    Lynch, MG
    [J]. OPHTHALMOLOGY, 2000, 107 (09) : 1687 - 1687
  • [3] SURGICAL REPAIR OF LEAKING BLEBS
    GALIN, MA
    HUNG, PT
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 1977, 83 (03) : 328 - &
  • [4] LEAKING FILTERING BLEBS
    SINNREICH, Z
    BARISHAK, R
    STEIN, R
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 1978, 86 (03) : 345 - 349
  • [5] Amniotic membrane transplantation for repair of leaking glaucoma filtering blebs
    Budenz, DL
    Barton, K
    Tseng, SCG
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2000, 130 (05) : 580 - 588
  • [6] Autologous conjunctival resurfacing of leaking filtering blebs
    Harris, LD
    Yang, G
    Feldman, RM
    Fellman, RL
    Starita, RJ
    Lynn, J
    Chuang, AZ
    [J]. OPHTHALMOLOGY, 2000, 107 (09) : 1675 - 1680
  • [7] MANAGEMENT OF LEAKING FILTERING BLEBS WITH THE DIODE LASER
    E.Segev
    O.Geyer
    [J]. 国际眼科杂志, 2003, (01) : 107 - 107
  • [8] CLOSURE OF LEAKING FILTERING BLEBS WITH CYANOACRYLATE TISSUE ADHESIVE
    ZALTA, AH
    WIEDER, RH
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 1991, 75 (03) : 170 - 173
  • [9] Efficiency and safety of human acellular dermal matrix for repair of leaking filtering blebs in rabbit eye
    Hong, Ying
    Liu, Ziyuan
    Zhang, Pei
    Wang, Wei
    [J]. INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2017, 10 (10): : 14536 - 14545
  • [10] Histopathologic study of five late leaking filtering blebs
    Murthy, RC
    Kurumety, UR
    Rao, NA
    Minckler, DS
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1997, 38 (04) : 4952 - 4952