Surgical repair of leaking filtering blebs

被引:43
|
作者
Wadhwani, RA
Bellows, AR
Hutchinson, BT
机构
[1] Harvard Univ, Sch Med, Dept Ophthalmol, Cambridge, MA 02138 USA
[2] Ophthalm Consultants Boston, Boston, MA 02114 USA
[3] Tufts Univ, Sch Med, New England Eye Ctr, Dept Ophthalmol, Boston, MA 02111 USA
关键词
D O I
10.1016/S0161-6420(00)00282-7
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To report the surgical management of leaking filtering blebs occurring after blebitis or persistent hypotony. Design: Retrospective, noncomparative case series. Participants: Twenty-two eyes of 20 patients with late bleb leak, blebitis or endophthalmitis, hypotony maculopathy, or bleb dysesthesia on presentation to the glaucoma service who required surgical bleb revision from 1990 through 1999. Intervention: Pedicle flap, partial excision, and advancement or free conjunctival autologous graft techniques for surgical bleb revision. Type of bleb revision was dependent on the dimensions of the bleb and quality. of surrounding conjunctiva. Main Outcome Measurer Preoperative and postoperative intraocular pressure (IOP), status of bleb leak, reoperation for glaucoma, or requirement for postrevision glaucoma medical therapy, with success defined as the need for two or fewer glaucoma medications after revision. Results: Eighty-six percent (19/22) of eyes that underwent surgical bleb revision had resolution of leak and IOP control using two or fewer medications after one or more bleb revisions. The preoperative IOP (mean +/- standard deviation) was 3.7 +/- 2.6 mmHg (range, 0-8 mmHg). After an average follow-up of 21 months (range, 8-108 months), the IOP was 11.0 +/- 4.4 mmHg for patients taking 0.6 +/- 1.0 glaucoma medications. Eighteen percent (4/22) of eyes required two or more bleb revisions. In one eye, an IOP spike of 36 mmHg developed after revision, which required laser suture lysis on two occasions before the IOP was significantly lowered. The three failures were: one eye that required three or more medications for IOP control, a patient whose eye had a persistent leak after revision and who was not mentally competent to undergo repeat revision, and one eye that required combined glaucoma and cataract surgery after revision. Conclusions: Surgical bleb revision has a high success rate of closing late bleb leaks, maintaining glaucoma control, and preserving vision, with few postoperative complications. The appropriate surgical procedure for revision must be based on the individual clinical situation and can result in successful bleb revision. Ophthalmology 2000;107:1681-1687 (C) 2000 by the American Academy of Ophthalmology.
引用
收藏
页码:1681 / 1687
页数:7
相关论文
共 50 条
  • [41] REPAIRING FILTERING BLEBS
    DELLAPORTA, A
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1982, 94 (02) : 269 - 271
  • [42] Encapsulated filtering blebs
    Cox, TA
    OPHTHALMOLOGY, 1996, 103 (01) : 1 - 1
  • [43] MANAGEMENT OF OVERFILTERING AND LEAKING BLEBS WITH AUTOLOGOUS BLOOD INJECTION
    LEEN, MM
    MOSTER, MR
    KATZ, LJ
    SCHMIDT, CM
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1994, 35 (04) : 1915 - 1915
  • [44] Management of overfiltering and leaking blebs with autologous blood injection
    Chen, PP
    Palmberg, PF
    Culbertson, WW
    Davis, JL
    ARCHIVES OF OPHTHALMOLOGY, 1996, 114 (05) : 633 - 633
  • [45] THE USE OF GLAUCOMA SHELL TAMPONADE IN LEAKING FILTRATION BLEBS
    MELAMED, S
    HERSH, P
    KERSTEN, D
    LEE, DA
    EPSTEIN, DL
    OPHTHALMOLOGY, 1986, 93 (06) : 839 - 842
  • [46] Bleb resuscitation of failing, leaking and dysfunctional blebs: A review
    Singh, Arshi
    Singh, Kirti
    Singh, Aastha
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2025, 73 (SUPPL 2) : S197 - S206
  • [47] MANAGEMENT OF OVERFILTERING AND LEAKING BLEBS WITH AUTOLOGOUS BLOOD INJECTION
    LEEN, MM
    MOSTER, MR
    KATZ, LJ
    TEREBUH, AK
    SCHMIDT, CM
    SPAETH, GL
    ARCHIVES OF OPHTHALMOLOGY, 1995, 113 (08) : 1050 - 1055
  • [48] Surgical repair of a leaking double postinfarction left ventricular pseudoaneurysm
    Milojevic, P
    Neskovic, V
    Vukovic, M
    Nezic, D
    Djukanovic, B
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2004, 128 (05): : 765 - 767
  • [49] DELLEN ASSOCIATED WITH FILTERING BLEBS
    LUNTZ, MH
    ARCHIVES OF OPHTHALMOLOGY, 1983, 101 (10) : 1629 - 1630
  • [50] REPAIRING FILTERING BLEBS - REPLY
    MAUMENEE, AE
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1982, 94 (02) : 271 - 271