Surgical repair of leaking filtering blebs

被引:43
|
作者
Wadhwani, RA
Bellows, AR
Hutchinson, BT
机构
[1] Harvard Univ, Sch Med, Dept Ophthalmol, Cambridge, MA 02138 USA
[2] Ophthalm Consultants Boston, Boston, MA 02114 USA
[3] Tufts Univ, Sch Med, New England Eye Ctr, Dept Ophthalmol, Boston, MA 02111 USA
关键词
D O I
10.1016/S0161-6420(00)00282-7
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To report the surgical management of leaking filtering blebs occurring after blebitis or persistent hypotony. Design: Retrospective, noncomparative case series. Participants: Twenty-two eyes of 20 patients with late bleb leak, blebitis or endophthalmitis, hypotony maculopathy, or bleb dysesthesia on presentation to the glaucoma service who required surgical bleb revision from 1990 through 1999. Intervention: Pedicle flap, partial excision, and advancement or free conjunctival autologous graft techniques for surgical bleb revision. Type of bleb revision was dependent on the dimensions of the bleb and quality. of surrounding conjunctiva. Main Outcome Measurer Preoperative and postoperative intraocular pressure (IOP), status of bleb leak, reoperation for glaucoma, or requirement for postrevision glaucoma medical therapy, with success defined as the need for two or fewer glaucoma medications after revision. Results: Eighty-six percent (19/22) of eyes that underwent surgical bleb revision had resolution of leak and IOP control using two or fewer medications after one or more bleb revisions. The preoperative IOP (mean +/- standard deviation) was 3.7 +/- 2.6 mmHg (range, 0-8 mmHg). After an average follow-up of 21 months (range, 8-108 months), the IOP was 11.0 +/- 4.4 mmHg for patients taking 0.6 +/- 1.0 glaucoma medications. Eighteen percent (4/22) of eyes required two or more bleb revisions. In one eye, an IOP spike of 36 mmHg developed after revision, which required laser suture lysis on two occasions before the IOP was significantly lowered. The three failures were: one eye that required three or more medications for IOP control, a patient whose eye had a persistent leak after revision and who was not mentally competent to undergo repeat revision, and one eye that required combined glaucoma and cataract surgery after revision. Conclusions: Surgical bleb revision has a high success rate of closing late bleb leaks, maintaining glaucoma control, and preserving vision, with few postoperative complications. The appropriate surgical procedure for revision must be based on the individual clinical situation and can result in successful bleb revision. Ophthalmology 2000;107:1681-1687 (C) 2000 by the American Academy of Ophthalmology.
引用
收藏
页码:1681 / 1687
页数:7
相关论文
共 50 条
  • [31] REPAIR OF INADVERTENT CONJUNCTIVAL FILTERING BLEBS WITH A SCLERAL FLAP
    CLINCH, TE
    KAUFMAN, HE
    ARCHIVES OF OPHTHALMOLOGY, 1992, 110 (11) : 1652 - 1653
  • [32] SURGICAL MANAGEMENT OF OVERHANGING BLEBS AFTER FILTERING PROCEDURES
    SCHEIE, HG
    GUEHL, JJ
    ARCHIVES OF OPHTHALMOLOGY, 1979, 97 (02) : 325 - 326
  • [33] REPAIR OF LATE LEAKING FILTERING BLEB AFTER TRABECULECTOMY
    ZHIOUA, R
    LASRAM, L
    KRIAA, L
    BENROMDHANE, B
    OUERTANI, A
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 1994, 17 (05): : 339 - 342
  • [34] Matrix metalloproteinase gelatinase B (MMP-9) is associated with leaking glaucoma filtering blebs
    Chintala, SK
    Wang, N
    Diskin, S
    Mattox, C
    Kagemann, L
    Fini, ME
    Schuman, JS
    EXPERIMENTAL EYE RESEARCH, 2005, 81 (04) : 429 - 436
  • [35] Clinicopathologic features and surgical management of dissecting glaucoma filtering blebs
    Ulrich, GG
    Proia, AD
    Shields, MB
    OPHTHALMIC SURGERY AND LASERS, 1997, 28 (02): : 151 - 155
  • [36] Is mitomycin really the culprit in leaking filtration blebs? Evidence from a clinical series of bleb expansion as a treatment for leaking blebs
    Solish, AM
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2002, 43 : U954 - U954
  • [37] Combined conjunctival relieving incisions and advancement for the repair of late-onset leaking trabeculectomy blebs
    Spencer, Narelle A.
    Lee, Cheryl
    Diamond, Jeremy P.
    JOURNAL OF GLAUCOMA, 2007, 16 (04) : 384 - 387
  • [38] SIMMONS TAMPONADE SHELL FOR LEAKING FILTRATION BLEBS
    RUDERMAN, JM
    ALLEN, RC
    ARCHIVES OF OPHTHALMOLOGY, 1985, 103 (11) : 1708 - 1710
  • [39] Dysfunctional filtering blebs
    Azuara-Blanco, A
    Katz, LJ
    SURVEY OF OPHTHALMOLOGY, 1998, 43 (02) : 93 - 126
  • [40] ENCAPSULATED FILTERING BLEBS
    FELDMAN, RM
    GROSS, RL
    WILSON, RP
    SPAETH, GL
    VARMA, R
    EAGLE, RC
    ARCHIVES OF OPHTHALMOLOGY, 1987, 105 (11) : 1589 - 1589