CLOSURE OF LEAKING FILTERING BLEBS WITH CYANOACRYLATE TISSUE ADHESIVE

被引:53
|
作者
ZALTA, AH [1 ]
WIEDER, RH [1 ]
机构
[1] UNIV CINCINNATI,COLL MED,DEPT OPHTHALMOL,CINCINNATI,OH 45221
关键词
D O I
10.1136/bjo.75.3.170
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Five leaking filtering blebs, occurring between 10 months and 21 years after trabeculectomy, were closed with cyanoacrylate tissue adhesive. Filtering bleb integrity was preserved in four cases, so that additional microsurgery was avoided. The only problem associated with use of tissue adhesive was the development of corneal abrasions in three cases. Although it is an accepted treatment for these conjunctival fistulas, only nine previous cases have been reported to our knowledge. We strongly recommend the use of tissue adhesive as a presurgical treatment in the management of leaking filtering blebs which present as a late postoperative complication of glaucoma surgery.
引用
收藏
页码:170 / 173
页数:4
相关论文
共 50 条
  • [1] THE USE OF CYANOACRYLATE ADHESIVE WITH A COLLAGEN SHIELD IN LEAKING FILTERING BLEBS
    WEBER, PA
    BAKER, ND
    OPHTHALMIC SURGERY AND LASERS, 1989, 20 (04): : 284 - 285
  • [2] LEAKING FILTERING BLEBS
    SINNREICH, Z
    BARISHAK, R
    STEIN, R
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1978, 86 (03) : 345 - 349
  • [3] Surgical repair of leaking filtering blebs
    Wadhwani, RA
    Bellows, AR
    Hutchinson, BT
    OPHTHALMOLOGY, 2000, 107 (09) : 1681 - 1687
  • [4] CLOSURE OF GASTROINTESTINAL PERFORATIONS WITH CYANOACRYLATE TISSUE ADHESIVE
    MATSUMOTO, T
    PANI, KC
    HARDAWAY, RM
    LEONARD, F
    ARCHIVES OF SURGERY, 1967, 94 (02) : 184 - +
  • [5] A SURGICAL METHOD TO REPAIR LEAKING FILTERING BLEBS
    OCONNOR, DJ
    TRESSLER, CS
    CAPRIOLI, J
    OPHTHALMIC SURGERY AND LASERS, 1992, 23 (05): : 336 - 338
  • [6] Autologous conjunctival resurfacing of leaking filtering blebs
    Harris, LD
    Yang, G
    Feldman, RM
    Fellman, RL
    Starita, RJ
    Lynn, J
    Chuang, AZ
    OPHTHALMOLOGY, 2000, 107 (09) : 1675 - 1680
  • [7] MANAGEMENT OF LEAKING FILTERING BLEBS WITH THE DIODE LASER
    E.Segev
    O.Geyer
    国际眼科杂志, 2003, (01) : 107 - 107
  • [8] Surgical repair of leaking filtering blebs - Discussion
    Lynch, MG
    OPHTHALMOLOGY, 2000, 107 (09) : 1687 - 1687
  • [9] CRYOSURGICAL CLOSURE OF FILTERING BLEBS
    CLEASBY, GW
    WEBSTER, RG
    FUNG, WE
    ARCHIVES OF OPHTHALMOLOGY, 1972, 87 (03) : 319 - &
  • [10] MANAGEMENT OF LEAKING FILTRATION BLEB WITH CYANOACRYLATE ADHESIVE
    P.P.Hentova-Sencanic
    Z.S.Micovic
    国际眼科杂志, 2003, (01) : 60 - 61