Autologous conjunctival resurfacing of leaking filtering blebs

被引:27
|
作者
Harris, LD
Yang, G
Feldman, RM
Fellman, RL
Starita, RJ
Lynn, J
Chuang, AZ
机构
[1] Univ Texas, Hlth Sci Ctr, Hermann Eye Ctr, Houston, TX 77030 USA
[2] Mem Hermann Hosp Syst, Ctr Hlth Care, Houston, TX USA
[3] Glaucoma Associates Texas, Dallas, TX USA
关键词
D O I
10.1016/S0161-6420(00)00280-3
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purposes To present a case series of a new technique to repair late bleb leaks. Designs:Retrospective, noncomparative, consecutive case series. Participants: Forty-seven autologous conjunctival resurfacings of late bleb leaks were performed by four surgeons at two institutions. Methods: Autologous conjunctival grafts were placed over existing de-epithelialized leaking blebs. Main Outcome Measures: Leak-free, Seidel-negative blebs and controlled glaucoma. Results: After a mean follow-up of 14 +/- 12 months, one patient continued to have bleb leak at the last follow-up, and one frank leak resolved with aqueous suppression. Intraocular pressure increased from 6.6 +/- 4.4 mmHg (0.13 glaucoma medications) to 11.9 +/- 4.1 mmHg (0.41 glaucoma medications). Conclusions: Conjunctival resurfacing with autologous tissue is an effective technique to repair late bleb leaks. Ophthalmology 2000;107:1675-1680 (C) 2000 by the American Academy of Ophthalmology.
引用
收藏
页码:1675 / 1680
页数:6
相关论文
共 50 条
  • [1] LEAKING FILTERING BLEBS
    SINNREICH, Z
    BARISHAK, R
    STEIN, R
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 1978, 86 (03) : 345 - 349
  • [2] Autologous platelet concentrate injection into overfiltrating or leaking filtering blebs
    Jonas, JB
    Klüter, H
    [J]. JOURNAL OF GLAUCOMA, 2001, 10 (03) : 251 - 251
  • [3] Reconstruction of leaking filtering blebs with rotational conjunctival flaps. Indications and outcome
    Hamard, P
    Tazartes, M
    Ayed, T
    Quesnot, S
    Hamard, H
    [J]. JOURNAL FRANCAIS D OPHTALMOLOGIE, 2001, 24 (05): : 482 - 490
  • [4] Surgical repair of leaking filtering blebs
    Wadhwani, RA
    Bellows, AR
    Hutchinson, BT
    [J]. OPHTHALMOLOGY, 2000, 107 (09) : 1681 - 1687
  • [5] A SURGICAL METHOD TO REPAIR LEAKING FILTERING BLEBS
    OCONNOR, DJ
    TRESSLER, CS
    CAPRIOLI, J
    [J]. OPHTHALMIC SURGERY AND LASERS, 1992, 23 (05): : 336 - 338
  • [6] MANAGEMENT OF LEAKING FILTERING BLEBS WITH THE DIODE LASER
    E.Segev
    O.Geyer
    [J]. 国际眼科杂志, 2003, (01) : 107 - 107
  • [7] Surgical repair of leaking filtering blebs - Discussion
    Lynch, MG
    [J]. OPHTHALMOLOGY, 2000, 107 (09) : 1687 - 1687
  • [8] Histopathologic features of conjunctival filtering blebs
    Francis, BA
    Du, LT
    Najafi, K
    Murthy, R
    Kurumety, U
    Rao, N
    Minckler, DS
    [J]. ARCHIVES OF OPHTHALMOLOGY, 2005, 123 (02) : 166 - 170
  • [9] MANAGEMENT OF OVERFILTERING AND LEAKING BLEBS WITH AUTOLOGOUS BLOOD INJECTION
    LEEN, MM
    MOSTER, MR
    KATZ, LJ
    SCHMIDT, CM
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1994, 35 (04) : 1915 - 1915
  • [10] Management of overfiltering and leaking blebs with autologous blood injection
    Chen, PP
    Palmberg, PF
    Culbertson, WW
    Davis, JL
    [J]. ARCHIVES OF OPHTHALMOLOGY, 1996, 114 (05) : 633 - 633