Design of an experimental system for dual energy X-ray CT

被引:0
|
作者
Sukovic, P [1 ]
Clinthorne, NH [1 ]
机构
[1] Univ Michigan, Ann Arbor, MI 48109 USA
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We present the design of a dual energy (DE) X-ray computed tomography (CT) test bench. It employs amorphous silicon (a-Si:H) imaging arrays and helical cone-beam geometry. Our goals are to evaluate: (1) the applicability of a-Si:H imaging arrays for tomography; (2) how our previously published dual energy penalized weighted least squares (DE PWLS) reconstruction method performs on experimentally acquired data; and (3) the optimal imaging geometry. This will allow us to design a setting that can be used clinically for attenuation correction for emission tomography, various quantitative computed tomography (QCT) applications, and removal of metal streak artifacts.
引用
收藏
页码:1021 / 1022
页数:2
相关论文
共 50 条
  • [41] X-Ray Spectra Optimization for Dual-Energy Imaging Using Dual-Source CT
    Giraldo, J. Ramirez
    Primak, A.
    Liu, X.
    McCollough, C.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [42] Rapid Screening of Methamphetamine by a X-ray Foreign Body Inspection System Equipped with Dual Energy X-ray Method
    Nakano, Kazuhiko
    Mizuta, Yutaka
    Yamazaki, Ryou
    Miyashita, Hiroumi
    Katada, Tetsu
    Nakamura, Masami
    Aoyama, Sigetoshi
    BUNSEKI KAGAKU, 2012, 61 (07) : 605 - 611
  • [43] Dynamic material decomposition method for MeV dual-energy X-ray CT
    Zhao, Tiao
    Li, Liang
    Chen, Zhiqiang
    APPLIED RADIATION AND ISOTOPES, 2018, 140 : 55 - 62
  • [44] Sensitivity of Dual-Energy CT, Ultrasound, and X-Ray for Pseudogout: A Pilot Study
    Tedeschi, Sara K.
    Solomon, Daniel
    Vanni, Kathleen
    Suh, Dong
    Smith, Stacy
    ARTHRITIS & RHEUMATOLOGY, 2019, 71
  • [45] Estimation of liver iron concentration by dual energy CT images: influence of X-ray energy on sensitivity
    Malvarosa, I.
    Massaroni, C.
    Liguori, C.
    Paul, J.
    Zobel, B. Beomonte
    Saccomandi, P.
    Vogl, T. J.
    Silvestri, S.
    Schena, E.
    2014 36TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2014, : 5129 - 5132
  • [46] Circuit Design of Energy Dispersive X-ray Fluorescence Analysis System
    Han, Xu
    PROCEEDINGS OF 2018 IEEE 4TH INFORMATION TECHNOLOGY AND MECHATRONICS ENGINEERING CONFERENCE (ITOEC 2018), 2018, : 945 - 950
  • [47] Dual-energy image noise reduction on an interventional x-ray system
    Nikolau, Ethan P.
    Whitehead, Joseph F.
    Wagner, Martin G.
    Laeseke, Paul F.
    Speidel, Michael A.
    MEDICAL IMAGING 2022: PHYSICS OF MEDICAL IMAGING, 2022, 12031
  • [48] Development of a dual detector phase x-ray imaging system: design considerations
    Liu, Hong
    Zhang, Da
    Wu, Xizeng
    2008 IEEE SOUTHWEST SYMPOSIUM ON IMAGE ANALYSIS & INTERPRETATION, 2008, : 193 - +
  • [49] Investigation of CT Image Quality Achievable From An Experimental Dual Mode Benchtop X-Ray Fluorescence CT (XFCT) and Micro-CT System
    Deng, L.
    Yasar, S.
    Ahmed, M. F.
    Park, Y.
    Jayarathna, S.
    Cho, S. H.
    MEDICAL PHYSICS, 2018, 45 (06) : E369 - E369
  • [50] A prototype rapid dual energy X-ray absorptiometry (DEXA) system can predict the CT composition of beef carcases
    Calnan, H.
    Williams, A.
    Peterse, J.
    Starling, S.
    Cook, J.
    Connaughton, S.
    Gardner, G. E.
    MEAT SCIENCE, 2021, 173