Design of an experimental system for dual energy X-ray CT

被引:0
|
作者
Sukovic, P [1 ]
Clinthorne, NH [1 ]
机构
[1] Univ Michigan, Ann Arbor, MI 48109 USA
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We present the design of a dual energy (DE) X-ray computed tomography (CT) test bench. It employs amorphous silicon (a-Si:H) imaging arrays and helical cone-beam geometry. Our goals are to evaluate: (1) the applicability of a-Si:H imaging arrays for tomography; (2) how our previously published dual energy penalized weighted least squares (DE PWLS) reconstruction method performs on experimentally acquired data; and (3) the optimal imaging geometry. This will allow us to design a setting that can be used clinically for attenuation correction for emission tomography, various quantitative computed tomography (QCT) applications, and removal of metal streak artifacts.
引用
收藏
页码:1021 / 1022
页数:2
相关论文
共 50 条
  • [21] CT Dual-energy Decomposition into X-ray Signatures ρe and Ze
    Martz, Harry E., Jr.
    Seetho, Isaac M.
    Champley, Kyle M.
    Smith, Jerel A.
    Azevedo, Stephen G.
    ANOMALY DETECTION AND IMAGING WITH X-RAYS (ADIX), 2016, 9847
  • [22] Distribution of electron density using dual-energy X-ray CT
    Tsunoo, T
    Torikoshi, M
    Sasaki, M
    Endo, M
    Yagi, N
    Uesugi, K
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2003, 50 (05) : 1678 - 1682
  • [23] X-ray attenuation coefficient of mixtures: Inputs for dual-energy CT
    Haghighi, Rezvan Ravanfar
    Chatterjee, S.
    Vyas, Akondi
    Kumar, Pratik
    Thulkar, Sanjay
    MEDICAL PHYSICS, 2011, 38 (10) : 5270 - 5279
  • [24] Dual-energy X-ray CT with a vertically expanded irradiation field
    Torikoshi, Masami
    Ohno, Yumiko
    Natsuhori, Masahiro
    Ito, Nobuhiko
    Uesugi, Kentaro
    Yagi, Naoto
    Tsunoo, Takanori
    De, Meng
    Endo, Masahiro
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 580 (02): : 996 - 999
  • [25] Dual-energy X-ray CT with CdTe array and its extension
    Ohno, Y
    Torikoshi, M
    Tsunoo, T
    Hyodo, K
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 548 (1-2): : 72 - 77
  • [26] Development of dual-energy X-ray CT using synchroton radiation
    Torikoshi, M
    Tsunoo, T
    Sasaki, M
    Endo, M
    Noda, Y
    Ohno, Y
    Kohno, T
    Natsuhori, M
    Kakizaki, T
    Yamada, N
    Itoh, N
    Hyodo, K
    Uesugi, K
    Yagi, N
    PORTABLE SYNCHROTRON LIGHT SOURCES AND ADVANCED APPLICATIONS, 2004, 716 : 160 - 163
  • [27] X-ray image denoising for Cargo Dual Energy Inspection System
    Yagoub, Bilel
    Ibrahem, Hatem
    Salem, Ahmed
    Suh, Jae-Won
    Kang, Hyun Soo
    2021 INTERNATIONAL CONFERENCE ON ELECTRONICS, INFORMATION, AND COMMUNICATION (ICEIC), 2021,
  • [28] Material discriminated X-ray CT system by using new X-ray imager with energy discriminate function
    Aoki, Toru
    Nakashima, Takuya
    Morii, Hisashi
    Neo, Yolchiro
    Mimura, Hidenori
    WMSCI 2007 : 11TH WORLD MULTI-CONFERENCE ON SYSTEMICS, CYBERNETICS AND INFORMATICS, VOL V, POST CONFERENCE ISSUE, PROCEEDINGS, 2007, : 307 - 310
  • [29] Contrast Enhanced Dual-Energy X-Ray Imaging System
    Sattarivand, M.
    Darvish-Molla, S.
    MEDICAL PHYSICS, 2019, 46 (06) : E105 - E105
  • [30] A Dual TLD System for X-Ray Energy Discrimination in Personnel Monitoring
    Nelson, V.
    McLean, I.
    Holloway, L.
    MEDICAL PHYSICS, 2011, 38 (06)