摘要
Background: Automated and convenient multianalyte detection with high throughput is increasingly needed in clinical diagnosis. We developed a disposable 4-by-2 array for programmed simultaneous amperometric immunoassay of 4 tumor markers. Methods: We used a screen-printed technique, 1-step immobilization method, and flow injection technique. We immobilized carcinoembryonic antigen, alpha-fetoprotein, beta-human choriogonadotropin, and carcinoma antigen 125 as model analytes in a redox mediator- grafted, biopolymer-modified, screen-printed carbon electrode array to capture corresponding horseradish peroxidase-labeled antibodies in competitive immunoreactions. The simultaneous multianalyte immunoassay was automatically carried out to amperometrically monitor the mediator-catalyzed enzymatic response to hydrogen peroxide, which decreased in proportion to the concentrations of analytes in samples. Results: The multianalyte immunosensor array had a throughput of 60 samples/h and allowed simultaneous detection of carcinoembryonic antigen, a-fetoprotein, beta-human choriogonadotropin, and carcinoma antigen 125 in clinical serum samples with concentrations up to 188 mu g/L, 250 mu g/L, 266 IU/L, and 334 kIU/L, respectively. The detection limits (limits of the blank, mean of blank plus 3 SD) were 1.1 mu g/L, 1.7 mu g/L, 1.2 IU/L, and 1.7 kIU/L. The inter- and intraassay imprecision (CVs) of the immunosensor arrays were < 7.8% and < 9.0%, respectively. The immunosensor arrays were stable for 28 days. Conclusions: This newly constructed immunosensor array provides a simple, automated, simultaneous multianalyte immunoassay with high throughput, short analytical time, and sufficiently low detection limits for clinical application. This method offers the capability of miniaturizing the multianalyte detection device. (c) 2007 American Association for Clinical Chemistry.
引用
收藏
页码:1495 / 1502
页数:8
相关论文
共 50 条
  • [21] Ultrasensitive determination of human growth hormone (hGH) with a disposable electrochemical magneto-immunosensor
    Serafin, V.
    Ubeda, N.
    Aguei, L.
    Yanez-Sedeno, P.
    Pingarron, J. M.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2012, 403 (04) : 939 - 946
  • [22] Ultrasensitive determination of human growth hormone (hGH) with a disposable electrochemical magneto-immunosensor
    V. Serafín
    N. Úbeda
    L. Agüí
    P. Yáñez-Sedeño
    J. M. Pingarrón
    Analytical and Bioanalytical Chemistry, 2012, 403 : 939 - 946
  • [23] A multianalyte flow electrochemical cell:: application to the simultaneous determination of carbohydrates based on bioelectrocatalytic detection
    Maestre, E
    Katakis, I
    Narváez, A
    Domínguez, E
    BIOSENSORS & BIOELECTRONICS, 2005, 21 (05): : 774 - 781
  • [24] A Label-free Immunosensor based on Ionic Liquids Modified Mesoporous Silica for Simultaneous Determination of Two Tumor Markers
    Lin Jiehua
    Zhang Huihui
    Shao Meijia
    ACTA CHIMICA SINICA, 2014, 72 (02) : 241 - 245
  • [25] Electrochemical immunosensors for the simultaneous detection of two tumor markers
    Wilson, MS
    ANALYTICAL CHEMISTRY, 2005, 77 (05) : 1496 - 1502
  • [26] An electrochemical immunosensor for simultaneous detection of two lung cancer markers based on electroactive probes
    Liu, Jianbo
    Liu, Jing
    Shang, Yonghui
    Xu, Jinqiong
    Wang, Xinyang
    Zheng, Jianbin
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2022, 919
  • [27] Simultaneous determination of five-type hepatitis virus antigens in 5 min using an integrated automatic electrochemical immunosensor array
    Tang, Dianping
    Tang, Juan
    Su, Biling
    Ren, Jingjing
    Chen, Guonan
    BIOSENSORS & BIOELECTRONICS, 2010, 25 (07): : 1658 - 1662
  • [28] Multianalyte sensor for the simultaneous determination of glucose, L-lactate and uric acid based on a microelectrode array
    Frebel, H
    Chemnitius, GC
    Cammann, K
    Kakerow, R
    Rospert, M
    Mokwa, W
    SENSORS AND ACTUATORS B-CHEMICAL, 1997, 43 (1-3) : 87 - 93
  • [29] Electrochemical immunosensor detection of tumor markers based on a GO composite nanoprobe for signal amplification
    Wang, Jing
    Yang, Dongcheng
    Chen, Mifa
    Liu, Beifang
    Chen, Hou
    Xu, Hui
    Wang, Wenxiang
    Bai, Liangjiu
    ANALYTICAL METHODS, 2018, 10 (05) : 526 - 532
  • [30] Disposable dual sensor array for simultaneous determination of chlorogenic acid and caffeine from coffee
    Vasilescu, Ioana
    Eremia, Sandra A. V.
    Penu, Ramona
    Albu, Camelia
    Radoi, Antonio
    Litescu, Simona C.
    Radu, Gabriel-Lucian
    RSC ADVANCES, 2015, 5 (01) : 261 - 268