A disposable multianalyte electrochemical immunosensor array for automated simultaneous determination of tumor markers

被引:95
|
作者
Wu, Jie
Yan, Feng
Tang, Jinhai
Zhai, Chun
Ju, Huangxian [1 ]
机构
[1] Nanjing Univ, Dept Chem, Minist Educ China, Key Lab Analyt Chem Life Sci, Nanjing 210093, Peoples R China
[2] Jiangsu Inst Canc Prevent & Cure, Nanjing 210009, Peoples R China
关键词
D O I
10.1373/clinchem.2007.086975
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: Automated and convenient multianalyte detection with high throughput is increasingly needed in clinical diagnosis. We developed a disposable 4-by-2 array for programmed simultaneous amperometric immunoassay of 4 tumor markers. Methods: We used a screen-printed technique, 1-step immobilization method, and flow injection technique. We immobilized carcinoembryonic antigen, alpha-fetoprotein, beta-human choriogonadotropin, and carcinoma antigen 125 as model analytes in a redox mediator- grafted, biopolymer-modified, screen-printed carbon electrode array to capture corresponding horseradish peroxidase-labeled antibodies in competitive immunoreactions. The simultaneous multianalyte immunoassay was automatically carried out to amperometrically monitor the mediator-catalyzed enzymatic response to hydrogen peroxide, which decreased in proportion to the concentrations of analytes in samples. Results: The multianalyte immunosensor array had a throughput of 60 samples/h and allowed simultaneous detection of carcinoembryonic antigen, a-fetoprotein, beta-human choriogonadotropin, and carcinoma antigen 125 in clinical serum samples with concentrations up to 188 mu g/L, 250 mu g/L, 266 IU/L, and 334 kIU/L, respectively. The detection limits (limits of the blank, mean of blank plus 3 SD) were 1.1 mu g/L, 1.7 mu g/L, 1.2 IU/L, and 1.7 kIU/L. The inter- and intraassay imprecision (CVs) of the immunosensor arrays were < 7.8% and < 9.0%, respectively. The immunosensor arrays were stable for 28 days. Conclusions: This newly constructed immunosensor array provides a simple, automated, simultaneous multianalyte immunoassay with high throughput, short analytical time, and sufficiently low detection limits for clinical application. This method offers the capability of miniaturizing the multianalyte detection device. (c) 2007 American Association for Clinical Chemistry.
引用
收藏
页码:1495 / 1502
页数:8
相关论文
共 50 条
  • [31] AN ENZYME IMMUNOSENSOR FOR THE ELECTROCHEMICAL DETERMINATION OF THE TUMOR-ANTIGEN ALPHA-FETOPROTEIN
    AIZAWA, M
    MORIOKA, A
    SUZUKI, S
    ANALYTICA CHIMICA ACTA, 1980, 115 (MAR) : 61 - 67
  • [32] Electric field-driven strategy for multiplexed detection of protein biomarkers using a disposable reagentless electrochemical immunosensor array
    Wu, Jie
    Yan, Yuetian
    Yan, Feng
    Ju, Huangxian
    ANALYTICAL CHEMISTRY, 2008, 80 (15) : 6072 - 6077
  • [33] Integrated disposable electrochemical immunosensors for the simultaneous determination of sulfonamide and tetracycline antibiotics residues in milk
    Conzuelo, Felipe
    Campuzano, Susana
    Gamella, Maria
    Pinacho, Daniel G.
    Julio Reviejo, A.
    Pilar Marco, M.
    Pingarron, Jose M.
    BIOSENSORS & BIOELECTRONICS, 2013, 50 : 100 - 105
  • [34] Electrochemical immunosensor based on metal ions functionalized CNSs@Au NPs nanocomposites as signal amplifier for simultaneous detection of triple tumor markers
    Li, Lihua
    Wei, Yan
    Zhang, Shengpeng
    Chen, Xishan
    Shao, Taili
    Feng, Dexiang
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2021, 880
  • [35] Simultaneous detection of two tumor markers using electrochemical immunosensor based on ultrathin metal-organic framework derived nanosheets as redox probes
    Huang, Xiaomei
    Deng, Xiang
    Deng, Zihe
    Huang, Chaoqin
    Zhu, Xiaoyu
    Sun, Li
    NEW JOURNAL OF CHEMISTRY, 2023, 47 (24) : 11651 - 11659
  • [36] Redox and catalysis 'all-in-one' infinite coordination polymer for electrochemical immunosensor of tumor markers
    Zhang, Bing
    Liu, Bingqian
    Chen, Guonan
    Tang, Dianping
    BIOSENSORS & BIOELECTRONICS, 2015, 64 : 6 - 12
  • [37] Electrochemical immunosensor for point-of-care quantitative detection of tumor markers based on personal glucometer
    Xu, Yang
    Wang, Huiqiang
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2022, 915
  • [38] A "signal-on" electrochemical aptasensor for simultaneous detection of two tumor markers
    Zhao, Jing
    He, Xiaolin
    Bo, Bing
    Liu, Xinjian
    Yin, Yongmei
    Li, Genxi
    BIOSENSORS & BIOELECTRONICS, 2012, 34 (01): : 249 - 252
  • [39] Disposable Amperometric Immunosensor for the Determination of the E-Cadherin Tumor Suppressor Protein in Cancer Cells and Human Tissues
    Munoz-San Martin, Cristina
    Pedrero, Maria
    Manuel de Villena, F. Javier
    Garranzo-Asensio, Maria
    Rodriguez, Nuria
    Dominguez, Gemma
    Barderas, Rodrigo
    Campuzano, Susana
    Pingarron, Jose M.
    ELECTROANALYSIS, 2019, 31 (02) : 309 - 317
  • [40] Simultaneous analysis of neuroendocrine tumor markers by HPLC-electrochemical detection
    Manickum, T.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (32): : 4140 - 4146