A disposable multianalyte electrochemical immunosensor array for automated simultaneous determination of tumor markers

被引:95
|
作者
Wu, Jie
Yan, Feng
Tang, Jinhai
Zhai, Chun
Ju, Huangxian [1 ]
机构
[1] Nanjing Univ, Dept Chem, Minist Educ China, Key Lab Analyt Chem Life Sci, Nanjing 210093, Peoples R China
[2] Jiangsu Inst Canc Prevent & Cure, Nanjing 210009, Peoples R China
关键词
D O I
10.1373/clinchem.2007.086975
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: Automated and convenient multianalyte detection with high throughput is increasingly needed in clinical diagnosis. We developed a disposable 4-by-2 array for programmed simultaneous amperometric immunoassay of 4 tumor markers. Methods: We used a screen-printed technique, 1-step immobilization method, and flow injection technique. We immobilized carcinoembryonic antigen, alpha-fetoprotein, beta-human choriogonadotropin, and carcinoma antigen 125 as model analytes in a redox mediator- grafted, biopolymer-modified, screen-printed carbon electrode array to capture corresponding horseradish peroxidase-labeled antibodies in competitive immunoreactions. The simultaneous multianalyte immunoassay was automatically carried out to amperometrically monitor the mediator-catalyzed enzymatic response to hydrogen peroxide, which decreased in proportion to the concentrations of analytes in samples. Results: The multianalyte immunosensor array had a throughput of 60 samples/h and allowed simultaneous detection of carcinoembryonic antigen, a-fetoprotein, beta-human choriogonadotropin, and carcinoma antigen 125 in clinical serum samples with concentrations up to 188 mu g/L, 250 mu g/L, 266 IU/L, and 334 kIU/L, respectively. The detection limits (limits of the blank, mean of blank plus 3 SD) were 1.1 mu g/L, 1.7 mu g/L, 1.2 IU/L, and 1.7 kIU/L. The inter- and intraassay imprecision (CVs) of the immunosensor arrays were < 7.8% and < 9.0%, respectively. The immunosensor arrays were stable for 28 days. Conclusions: This newly constructed immunosensor array provides a simple, automated, simultaneous multianalyte immunoassay with high throughput, short analytical time, and sufficiently low detection limits for clinical application. This method offers the capability of miniaturizing the multianalyte detection device. (c) 2007 American Association for Clinical Chemistry.
引用
收藏
页码:1495 / 1502
页数:8
相关论文
共 50 条
  • [41] Electrochemical immunosensor for the determination of 8-isoprostane aging biomarker using carbon nanohorns-modified disposable electrodes
    Sanchez-Tirado, E.
    Gonzalez-Cortes, A.
    Yudasaka, M.
    Iijima, S.
    Langa, F.
    Yanez-Sedeno, P.
    Pingarron, J. M.
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2017, 793 : 197 - 202
  • [42] Simultaneous determination of lead, arsenic, and mercury in cosmetics using a plastic based disposable electrochemical sensor
    Wang, Wan
    Bao, Ning
    Yuan, Wenfeng
    Si, Nianpeng
    Bai, Hua
    Li, Haiyu
    Zhang, Qing
    MICROCHEMICAL JOURNAL, 2019, 148 : 240 - 247
  • [43] A new disposable microfluidic electrochemical paper-based device for the simultaneous determination of clinical biomarkers
    Cincotto, Fernando H.
    Fava, Elson L.
    Moraes, Fernando C.
    Fatibello-Filho, Orlando
    Faria, Ronaldo C.
    TALANTA, 2019, 195 : 62 - 68
  • [44] Multiplexed electrochemical immunosensor for label-free detection of cardiac markers using a carbon nanofiber array chip
    Gupta, Rakesh K.
    Pandya, Ruchi
    Sieffert, Theodore
    Meyyappan, M.
    Koehne, Jessica E.
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2016, 773 : 53 - 62
  • [45] Simultaneous detection of tumor markers in lung cancer using scanning electrochemical microscopy
    Ning, Xin
    Xiong, Qiang
    Zhang, Fan
    He, Pingang
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2018, 812 : 101 - 106
  • [46] A disposable immunosensor array using cellulose paper assembled chemiresistive biosensor for simultaneous monitoring of mycotoxins AFB1 and FB1
    He, Yue
    Wang, Hui
    Yu, Zhixue
    Tang, Xiangfang
    Zhou, Mengting
    Guo, Yuming
    Xiong, Benhai
    TALANTA, 2024, 276
  • [47] Simultaneous electrochemical determination of acetaminophen and metoclopramide at electrochemically pre-treated disposable graphite pencil electrode
    Patil, Shreekant M.
    Pattar, Vijay P.
    Nandibewoor, Sharanappa T.
    JOURNAL OF ELECTROCHEMICAL SCIENCE AND ENGINEERING, 2016, 6 (03): : 265 - 276
  • [48] Large scale fabrication of disposable carbon cloth electrochemical sensors for simultaneous determination of heavy metal ion
    Shi, Huilan
    Zhu, Fudan
    Zhou, Xian
    Li, Hui
    Yang, Fengchun
    Zhang, Xin
    Liu, Jingtao
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2019, 840 : 328 - 337
  • [49] Probe-integrated electrochemical immunosensor based on electrostatic nanocage array for reagentless and sensitive detection of tumor biomarker
    Chen, Dong
    Luo, Xuan
    Xi, Fengna
    FRONTIERS IN CHEMISTRY, 2023, 11
  • [50] A streptavidin-functionalized tin disulfide nanoflake-based ultrasensitive electrochemical immunosensor for the detection of tumor markers
    Shen, Huifang
    Wang, Chu
    Ren, Chuanli
    Zhang, Geshan
    Zhang, Yongcai
    Li, Juan
    Hu, Xiaoya
    Yang, Zhanjun
    NEW JOURNAL OF CHEMISTRY, 2020, 44 (15) : 6010 - 6014