A Label-free Immunosensor based on Ionic Liquids Modified Mesoporous Silica for Simultaneous Determination of Two Tumor Markers

被引:5
|
作者
Lin Jiehua [1 ]
Zhang Huihui [1 ]
Shao Meijia [1 ]
机构
[1] Qingdao Univ Sci & Technol, Coll Chem & Mol Engn, Qingdao 266042, Peoples R China
关键词
immunosensor; double-analyte detection; mesoporous silica; label-free determination; tumor markers; NANOPARTICLES; ELECTRODE; ELECTROCHEMISTRY; IMMUNOASSAY; ANTIBODIES; COPOLYMER; TRIBLOCK; STRATEGY; PORES; ARRAY;
D O I
10.6023/A13101057
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A label-free electrochemical immunoassay strategy was proposed for the simultaneous detection of two tumor markers, carcinoembryonic antigen (CEA) and alpha-fetoprotein (AFP). The functional mesoporous silica was synthesized for the construction of the label-free immunosensor. The Si-OH groups on the external surface of the mesoporous silica were terminated by trimethylchlorosilane (TMCS), while the Si-OH groups on the internal pore walls were modified with amino groups. The electrochemical substrates of ferrocenecarboxylic acid (FCA) and methylene blue (MB) were co-immobilized inside the channels of the ionic liquids (ILs) modified mesoporous silica (MPS), respectively. The monoclonal antibody of CEA (anti-CEA) and the monoclonal antibody of APP (anti-APP) were respectively co-immobilized inside the materials of FCA-IL-MPS and MB-IL-MPS. The ITO slide was separated lengthways into two uniform parts by insulation glue so as to avoid the cross-talk of the two portions. Finally, the suspension solutions were coated respectively onto the different areas of indium-tin oxide (ITO) electrode. The double-analyte immunosensor was constructed by the probes of CEA and AFP onto the different areas of ITO. When the double-analyte immunosensor was dipped into the sample solution, the antigens of CEA and AFP reacted with their corresponding monoclonal antibodies on the different area of the modified ITO electrode. After the immunological reaction, the nonconductive immunoconjugates formed inside the MPS channels. With the increasing concentrations of CEA and AFP antigens, the spatial blocking and impedance on the sensor surface increased, thus the electric response transfer from the solution to the electrode surface was blocked and the DPV currents decreased. The electrochemical signals for CEA were detected by using FCA as the electron mediator. The electrochemical signals for AFP were detected by using MB as the electrochemical substrates. Then, the simultaneous detection of CEA and AFP could be achieved. The electrode modification process was further characterized by cyclic voltammetric measurements and electrochemical impedance spectroscopy. IL units inside the mesopores could promote the electron transportation through the pore channel. To clarify the adsorption of FCA and MB into the mesopores of ILs-modified MPS, the IR spectra were recorded. The linear ranges of CEA and AFP were 0.5 similar to 80 ng.mL(-1) and 0.5 similar to 100 ng.mL(-1) with the detection limits of 0.1 ng.mL(-1) and 0.1 ng.mL(-1) (S/N=3), respectively. The fabricated immunosensor shows appropriate sensitivity because of the good electric conductivity of ILs. It is an alternative to the multianalyte detection of antigens or other bioactive molecules.
引用
收藏
页码:241 / 245
页数:5
相关论文
共 24 条
  • [1] Stochastic sensors inspired by biology
    Bayley, H
    Cremer, PS
    [J]. NATURE, 2001, 413 (6852) : 226 - 230
  • [2] Non-haloaluminate room-temperature ionic liquids in electrochemistry - A review
    Buzzeo, MC
    Evans, RG
    Compton, RG
    [J]. CHEMPHYSCHEM, 2004, 5 (08) : 1106 - 1120
  • [3] Ionic liquids: Promising solvents for electrochemistry
    Endres, F
    [J]. ZEITSCHRIFT FUR PHYSIKALISCHE CHEMIE-INTERNATIONAL JOURNAL OF RESEARCH IN PHYSICAL CHEMISTRY & CHEMICAL PHYSICS, 2004, 218 (02): : 255 - 283
  • [4] ESCOSURAMUNIZ ADL, 2010, ELECTROCHEM COMMUN, V12, P859
  • [5] Surface acoustic wave immunosensor for real-time detection of hepatitis B surface antibodies in whole blood samples
    Lee, Hun Joo
    Namkoong, Kak
    Cho, Eun Chol
    Ko, Christopher
    Park, Jae Chan
    Lee, Soo Suk
    [J]. BIOSENSORS & BIOELECTRONICS, 2009, 24 (10): : 3120 - 3125
  • [6] Disposable biosensor based on enzyme immobilized on Au-chitosan-modified indium tin oxide electrode with flow injection amperometric analysis
    Lin, Jiehua
    Qu, Wei
    Zhang, Shusheng
    [J]. ANALYTICAL BIOCHEMISTRY, 2007, 360 (02) : 288 - 293
  • [7] A New Dual Immunoassay for the Determination of α-Fetoprotein and Carcinoembryonic Antigen Based on Chemiluminescence Signal Amplification by Functional Graphite Oxide
    Lin Jiehua
    Zhang Huihui
    Chu Pengfei
    [J]. ACTA CHIMICA SINICA, 2012, 70 (22) : 2372 - 2376
  • [8] Sensitive immunosensor for the label-free determination of tumor marker based on carbon nanotubes/mesoporous silica and graphene modified electrode
    Lin, Jiehua
    Wei, Zhijing
    Zhang, Huihui
    Shao, Meijia
    [J]. BIOSENSORS & BIOELECTRONICS, 2013, 41 : 342 - 347
  • [9] A label-free immunosensor by controlled fabrication of monoclonal antibodies and gold nanoparticles inside the mesopores
    Lin, Jiehua
    Wei, Zhijing
    Chu, Pengfei
    [J]. ANALYTICAL BIOCHEMISTRY, 2012, 421 (01) : 97 - 102
  • [10] A label-free immunosensor based on modified mesoporous silica for simultaneous determination of tumor markers
    Lin, Jiehua
    Wei, Zhijing
    Mao, Changming
    [J]. BIOSENSORS & BIOELECTRONICS, 2011, 29 (01): : 40 - 45