Analysis of tumor-influenced respiratory dynamics using motion artifact reduced thoracic 4D CT images

被引:0
|
作者
Werner, Ren [1 ]
Ehrhardt, Jan [1 ]
Frenzel, Thorsten [2 ]
Lu, Wei [3 ]
Low, Daniel [3 ]
Handels, Heinz [1 ]
机构
[1] Univ Hamburg, Med Ctr, Dept Med Informat, Martinistr 52, D-2000\ Hamburg, Germany
[2] AK St George Hosp, Hermann Holthusen Inst Radiothe, Hamburg, Germany
[3] Washington Univ, Sch Med, Dept Radiat Oncol, St Louis, MO 63110 USA
来源
关键词
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Respiratory motion represents a major problem in radiation therapy of thoracic tumors. Methods for compensation require comprehensive knowledge of underlying dynamics. In this study, motion of thoracic anatomical and pathological structures in lung cancer patients was analyzed using motion artifact reduced 4D CT data sets of high temporal and spatial resolution. Motion artifact reduction was achieved by applying an optical flow based 4D CT reconstruction method. Motion analysis especially focuses on inner organ and tumor mobility and the interrelation between tumor/inner organ motion and chest wall motion. Trajectories of tumor mass centers and organ specific landmarks were determined and analyzed. To study chest wall motion a non-linear registration based point tracking scheme was applied to compute trajectories of points on the chest wall skin. The interrelation of chest wall and tumor/inner organ motion was investigated using methods of multivariate statistics. Results show that, for instance, tumor motion patterns differ noticeably between the patients; a dependency between tumor motion and tumor location seems apparent. The correlation of tumor motion and motion of chest wall points depends on the patient breathing pattern (e.g. abdominal or chest wall breathing). Thus, skin regions which are suitable for prediction of tumor motion differ between the patients.
引用
收藏
页码:181 / +
页数:2
相关论文
共 50 条
  • [21] IMAGE-BASED MOTION DETECTION IN 4D IMAGES AND APPLICATION TO RESPIRATORY MOTION SUPPRESSION
    Breuilly, M.
    Malandain, G.
    Ayache, N.
    Guglielmi, J.
    Pourcher, T.
    Franken, P. R.
    Darcourt, J.
    2013 IEEE 10TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2013, : 804 - 807
  • [22] Motion Artifact Reduction in 4D Helical CT: Graph-Based Structure Alignment
    Han, Dongfeng
    Bayouth, John
    Bhatia, Sudershan
    Sonka, Milan
    Wu, Xiaodong
    MEDICAL COMPUTER VISION: RECOGNITION TECHNIQUES AND APPLICATIONS IN MEDICAL IMAGING, 2011, 6533 : 63 - 73
  • [23] Abdominal organ motion measured using 4D CT
    Brandner, Edward D.
    Wu, Andrew
    Chen, Hungcheng
    Heron, Dwight
    Kalnicki, Shalom
    Komanduri, Krishna
    Gerszten, Kristina
    Burton, Steve
    Ahmed, Irfan
    Shou, Zhenyu
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 65 (02): : 554 - 560
  • [24] Towards a Generic Respiratory Motion Model for 4D CT Imaging of the Thorax
    Fayad, H.
    Clement, J. F.
    Pan, T.
    Roux, C.
    Le Rest, C. Cheze
    Pradier, O.
    Visvikis, D.
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 3975 - +
  • [25] Iterative sorting for 4D CT images based on internal anatomic motion
    Zeng, R.
    Balter, J.
    Fessler, J.
    MEDICAL PHYSICS, 2007, 34 (06) : 2388 - 2388
  • [26] Tracking the motion trajectories of junction structures in 4D CT images of the lung
    Xiong, Guanglei
    Chen, Chuangzhen
    Chen, Jianzhou
    Xie, Yaoqin
    Xing, Lei
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (15): : 4905 - 4930
  • [27] Tumor and normal tissue motion in the thorax during respiration: Analysis of volumetric and positional variations using 4D CT
    Weiss, Elisabeth
    Wijesooriya, Krishni
    Dill, S. Vaughn
    Keall, Paul J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 67 (01): : 296 - 307
  • [28] Evaluation of a Novel Sequential 4D Scan Technique for Reduced Motion Artifacts in Respiratory-Gated CT Scans
    Cammin, J.
    Morris, R.
    MEDICAL PHYSICS, 2020, 47 (06) : E367 - E368
  • [29] Tumor and normal tissue motion in the thorax during respiration: Analysis of volumetric and positional variations using 4D CT
    Weiss, E.
    Wijesooriya, K.
    Dill, S. V.
    Keall, P. J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03): : S484 - S484
  • [30] EVALUATION OF THE RESPIRATORY PROSTATE MOTION WITH 4D CT SCANS ACQUISITION USING THREE IMPLANTED MARKERS
    Udrescu, C.
    Jalade, P.
    Michel-Amadry, G.
    De Bari, B.
    Chapet, O.
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S401 - S402