Analysis of tumor-influenced respiratory dynamics using motion artifact reduced thoracic 4D CT images

被引:0
|
作者
Werner, Ren [1 ]
Ehrhardt, Jan [1 ]
Frenzel, Thorsten [2 ]
Lu, Wei [3 ]
Low, Daniel [3 ]
Handels, Heinz [1 ]
机构
[1] Univ Hamburg, Med Ctr, Dept Med Informat, Martinistr 52, D-2000\ Hamburg, Germany
[2] AK St George Hosp, Hermann Holthusen Inst Radiothe, Hamburg, Germany
[3] Washington Univ, Sch Med, Dept Radiat Oncol, St Louis, MO 63110 USA
来源
关键词
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Respiratory motion represents a major problem in radiation therapy of thoracic tumors. Methods for compensation require comprehensive knowledge of underlying dynamics. In this study, motion of thoracic anatomical and pathological structures in lung cancer patients was analyzed using motion artifact reduced 4D CT data sets of high temporal and spatial resolution. Motion artifact reduction was achieved by applying an optical flow based 4D CT reconstruction method. Motion analysis especially focuses on inner organ and tumor mobility and the interrelation between tumor/inner organ motion and chest wall motion. Trajectories of tumor mass centers and organ specific landmarks were determined and analyzed. To study chest wall motion a non-linear registration based point tracking scheme was applied to compute trajectories of points on the chest wall skin. The interrelation of chest wall and tumor/inner organ motion was investigated using methods of multivariate statistics. Results show that, for instance, tumor motion patterns differ noticeably between the patients; a dependency between tumor motion and tumor location seems apparent. The correlation of tumor motion and motion of chest wall points depends on the patient breathing pattern (e.g. abdominal or chest wall breathing). Thus, skin regions which are suitable for prediction of tumor motion differ between the patients.
引用
收藏
页码:181 / +
页数:2
相关论文
共 50 条
  • [41] Internal Tumor Volume Motion and Volume Size Assessment Using 4D CT Lung Data
    Jurkovic, I.
    Stathakis, S.
    Li, Y.
    Patel, A.
    Vincent, J.
    Papanikolaou, N.
    Mavroidis, P.
    MEDICAL PHYSICS, 2014, 41 (06) : 173 - 173
  • [42] Optimising heart substructure visibility in 4D planning CT by compensating respiratory motion
    van Herk, M.
    Marchant, T.
    Henderson, E.
    McSweeney, D.
    Abravan, A.
    Osorio, E. Vasquez
    McWilliam, A.
    Faivre-Finn, C.
    Price, G.
    RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S1381 - S1382
  • [43] 4D Cardiac Reconstruction Using High Resolution CT Images
    Gao, Mingchen
    Huang, Junzhou
    Zhang, Shaoting
    Qian, Zhen
    Voros, Szilard
    Metaxas, Dimitris
    Axel, Leon
    FUNCTIONAL IMAGING AND MODELING OF THE HEART, 2011, 6666 : 153 - 160
  • [44] 4D PET/CT as a strategy to reduce respiratory motion artifacts in FDG-PET/CT
    Chi, Alexander
    Nguyen, Nam P.
    FRONTIERS IN ONCOLOGY, 2014, 4
  • [45] Effect of respiratory motion on abdominal C-arm CT angiography using the 4D NCAT phantom
    Fung, G. S. K.
    Segars, W. P.
    Geschwind, J. -F. H.
    Tsui, B. M. W.
    Taguchi, K.
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 4536 - +
  • [46] Acquiring 4D thoracic CT scans using a multislice helical method
    Keall, PJ
    Starkschall, G
    Shukla, H
    Forster, KM
    Ortiz, V
    Stevens, CW
    Vedam, SS
    George, R
    Guerrero, T
    Mohan, R
    PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (10): : 2053 - 2067
  • [47] Digital reconstruction of high-quality daily 4D cone-beam CT images using prior knowledge of anatomy and respiratory motion
    Zhang, Yongbin
    Yang, Jinzhong
    Zhang, Lifei
    Court, Laurence E.
    Gao, Song
    Balter, Peter A.
    Dong, Lei
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2015, 40 : 30 - 38
  • [48] Differences in respiratory-induced pancreatic tumor motion between 4D treatment planning CT and daily cone beam CT, measured using intratumoral fiducials
    Lens, Eelco
    van der Horst, Astrid
    Kroon, Petra S.
    van Hooft, Jeanin E.
    Fajardo, Raquel Davila
    Fockens, Paul
    van Tienhoven, Geertjan
    Bel, Arjan
    ACTA ONCOLOGICA, 2014, 53 (09) : 1257 - 1264
  • [49] 4D IMRT optimization accomodating respiratory motion using image mapping
    Joshi, S
    Cullip, T
    Davis, B
    Chang, S
    Keall, P
    Erdi, Y
    Nehmeh, S
    Mageras, G
    Rosenman, J
    MEDICAL PHYSICS, 2004, 31 (06) : 1852 - 1852
  • [50] Synthesizing Continuous 4D Respiratory Motion Using a Conditional Registration Network
    Sang, Y.
    Ruan, D.
    MEDICAL PHYSICS, 2022, 49 (06) : E159 - E160