Analysis of tumor-influenced respiratory dynamics using motion artifact reduced thoracic 4D CT images

被引:0
|
作者
Werner, Ren [1 ]
Ehrhardt, Jan [1 ]
Frenzel, Thorsten [2 ]
Lu, Wei [3 ]
Low, Daniel [3 ]
Handels, Heinz [1 ]
机构
[1] Univ Hamburg, Med Ctr, Dept Med Informat, Martinistr 52, D-2000\ Hamburg, Germany
[2] AK St George Hosp, Hermann Holthusen Inst Radiothe, Hamburg, Germany
[3] Washington Univ, Sch Med, Dept Radiat Oncol, St Louis, MO 63110 USA
来源
关键词
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Respiratory motion represents a major problem in radiation therapy of thoracic tumors. Methods for compensation require comprehensive knowledge of underlying dynamics. In this study, motion of thoracic anatomical and pathological structures in lung cancer patients was analyzed using motion artifact reduced 4D CT data sets of high temporal and spatial resolution. Motion artifact reduction was achieved by applying an optical flow based 4D CT reconstruction method. Motion analysis especially focuses on inner organ and tumor mobility and the interrelation between tumor/inner organ motion and chest wall motion. Trajectories of tumor mass centers and organ specific landmarks were determined and analyzed. To study chest wall motion a non-linear registration based point tracking scheme was applied to compute trajectories of points on the chest wall skin. The interrelation of chest wall and tumor/inner organ motion was investigated using methods of multivariate statistics. Results show that, for instance, tumor motion patterns differ noticeably between the patients; a dependency between tumor motion and tumor location seems apparent. The correlation of tumor motion and motion of chest wall points depends on the patient breathing pattern (e.g. abdominal or chest wall breathing). Thus, skin regions which are suitable for prediction of tumor motion differ between the patients.
引用
收藏
页码:181 / +
页数:2
相关论文
共 50 条
  • [31] Abdominal and pancreatic motion correlation using 4D CT, 4D transponders, and a gating belt
    Betancourt, Ricardo
    Zou, Wei
    Plastaras, John P.
    Metz, James M.
    Teo, Boon-Keng
    Kassaee, Alireza
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2013, 14 (03): : 13 - 24
  • [32] LOCAL MOTION ANALYSIS IN 4D LUNG CT USING FAST GROUPWISE REGISTRATION
    Bystrov, D.
    Vik, T.
    Schulz, H.
    Klinder, T.
    Schmidt, S.
    2009 16TH IEEE INTERNATIONAL CONFERENCE ON IMAGE PROCESSING, VOLS 1-6, 2009, : 1749 - +
  • [33] Cardiac motion and strain detection using 4D CT images: comparison with tagged MRI, and echocardiography
    Tavakoli, Vahid
    Sahba, Nima
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2014, 30 (01): : 175 - 184
  • [34] Cardiac motion and strain detection using 4D CT images: comparison with tagged MRI, and echocardiography
    Vahid Tavakoli
    Nima Sahba
    The International Journal of Cardiovascular Imaging, 2014, 30 : 175 - 184
  • [35] Impact of baseline shifts on 4D cone-beam CT images using a 4D phantom driven by lung tumor motions
    Moriwaki, H.
    Shiraishi, K.
    Sakumi, A.
    Ikeda, T.
    Shimizu, W.
    Yoda, K.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S981 - S981
  • [36] Image quality enhancement using motion estimation in 4D CT images of lung cancer patients
    Wolthaus, J.
    Sonke, J.
    van Herk, M.
    Zijp, L.
    Lebesque, J.
    Damen, E.
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S110 - S110
  • [37] Evaluation of mesh- and binary-based contour propagation methods in 4D thoracic radiotherapy treatments using patient 4D CT images
    Ma, Yuanyuan
    Liu, Xinguo
    Dai, Zhongying
    He, Pengbo
    Yan, Yuanlin
    Shen, Guosheng
    Yuan, Ping
    Li, Qiang
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 36 : 46 - 53
  • [38] Evaluation of the combined effects of target size, respiratory motion and background activity on 3D and 4D PET/CT images
    Park, Sang-June
    Ionascu, Dan
    Killoran, Joseph
    Mamede, Marcelo
    Gerbaudo, Victor H.
    Chin, Lee
    Berbeco, Ross
    PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (13): : 3661 - 3679
  • [39] Evaluation of Combined Effects of Target Size, Background Activity, and Respiratory Motion On 3D and 4D PET/CT Images
    Park, S.
    Ionascu, T.
    Killoran, J.
    Mamede, M.
    Gerbaudo, V.
    Chin, L.
    Berbeco, R.
    MEDICAL PHYSICS, 2008, 35 (06) : 2896 - +
  • [40] 4D-CT imaging of a volume influenced by respiratory motion on multi-slice CT
    Pan, T
    Lee, TY
    Rietzel, E
    Chen, GTY
    MEDICAL PHYSICS, 2004, 31 (02) : 333 - 340